12323 matches found
CVE-2019-14360
On Hyundai Pay Kasse HK-1000 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might...
CVE-2019-14358
On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to...
CVE-2019-14358
CVE-2019-14358 concerns Archos Safe-T hardware wallets. A side-channel exists in the row-based OLED display where the power draw of each display cycle correlates with the number of illuminated pixels, enabling partial recovery of display contents. The documented risk requires the attacker to have...
CVE-2019-18673
On SHIFT BitBox02 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to...
PT-2019-13639
Name of the Vulnerable Software and Affected Versions Hyundai Pay Kasse HK-1000 devices affected versions not specified Description A side channel was discovered related to the row-based OLED display on the devices. The power consumption of each display cycle varies based on the number of...
Solar, Wind Power Utility Disrupted in Rare Cyberattack
A cyberattack on the U.S. energy grid has just come to light, so to speak, which disrupted plant visibility at Utah-based sPower back in March. sPower, a Utah-based wind and solar provider, began experiencing a series of lost connections between its main control center and remote power-generation...
CVE-2019-14356
On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be...
CVE-2019-14356
On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be...
Buffer overflow
DISPUTED On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable...
CVE-2019-14356
CVE-2019-14356 affects Coldcard MK1 and MK2 devices. A side-channel in the OLED row-based display lets an attacker who can control or monitor USB power measurements during times secrets are shown partially recover display contents, potentially exposing PINs and BIP39 mnemonics. The vulnerability ...
CVE-2019-14356
On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be...
Hackers Target Indian Nuclear Power Plant – Everything We Know So Far
A story has been making the rounds on the Internet since yesterday about a cyber attack on an Indian nuclear power plant. Due to some experts commentary on social media even after lack of information about the event and overreactions by many, the incident received factually incorrect coverage...
Siemens SIPROTEC 5 7SL82 Power Systems Monitoring and Protection Device
Binary data 765255.prm...
File Read Vulnerability in Huatian Power OA System
Huatian Power OA system is a collaborative office software developed by Dalian Huatian Software Co. A file read vulnerability exists in the Huatian Power OA system, which can be exploited by attackers to obtain sensitive information...
Siemens SIPROTEC 5 7SK85 Power Systems Monitoring and Protection Device
Binary data 765254.prm...
Siemens SIPROTEC 5 7SS85 Power Systems Monitoring and Protection Device
Binary data 765258.prm...
Siemens SIPROTEC 5 7SA82 Power Systems Monitoring and Protection Device
Binary data 765244.prm...
Siemens SIPROTEC 5 7SD82 Power Systems Monitoring and Protection Device
Binary data 765247.prm...