Lucene search
+L

12074 matches found

NVD
NVD
added 2025/08/12 12:15 p.m.9 views

CVE-2025-40752

A vulnerability has been identified in POWER METER SICAM Q100 7KG9501-0AA01-0AA1 All versions = V2.60 = V2.60 = V2.60 = V2.60 = V2.70 V2.80. Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configure...

6.8CVSS0.00092EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/08/12 11:17 a.m.5 views

CVE-2025-40752

A vulnerability has been identified in POWER METER SICAM Q100 7KG9501-0AA01-0AA1 All versions = V2.60 = V2.60 = V2.60 = V2.60 = V2.70 V2.80. Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configure...

6.8CVSS7AI score0.00092EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/08/12 11:17 a.m.16 views

CVE-2025-40752

A vulnerability has been identified in POWER METER SICAM Q100 7KG9501-0AA01-0AA1 All versions = V2.60 = V2.60 = V2.60 = V2.60 = V2.70 V2.80. Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configure...

6.8CVSS0.00092EPSS
SaveExploits0References1
ICS
ICS
added 2025/08/12 4:0 a.m.13 views

Schneider Electric EcoStruxure Power Monitoring Expert

RISK EVALUATION Successful exploitation of these vulnerabilities could allow a remote attacker to read arbitrary files from the target machine, or to access internal services directly. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of...

8.1AI score
SaveExploits0References11
Positive Technologies
Positive Technologies
added 2025/08/12 12:0 a.m.9 views

PT-2025-32893 · Schneider Electric · Ecostruxure Power Monitoring Expert

Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: This issue is a directory traversal information disclosure vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert. The...

7.2CVSS6.6AI score0.00908EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2025/08/12 12:0 a.m.11 views

PT-2025-32891 · Schneider Electric · Ecostruxure Power Monitoring Expert

Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: This issue is a server-side request forgery SSRF information disclosure vulnerability within the GetPagesAsImages functionality of Schneider...

7.5CVSS6.6AI score0.00455EPSS
SaveExploits0References7
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:0 a.m.3 views

Linux Distros Unpatched Vulnerability : CVE-2024-40926

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - In the Linux kernel, the following vulnerability has been resolved: drm/nouveau: don't attempt to schedule hpdwork on headless cards If the card doesn't have...

5.5CVSS4.9AI score0.0024EPSS
SaveExploits0References2
Packet Storm News
Packet Storm News
added 2025/08/12 12:0 a.m.6 views

Load-Altering Attacks against Power Grids: a Case Study Using the GB-36 Bus System Open Dataset

The growing digitalization and the rapid adoption of high-powered Internet-of-Things IoT-enabled devices e.g., EV charging stations have increased the vulnerability of power grids to cyber threats. In particular, the so-called Load Altering Attacks LAAs can trigger rapid frequency fluctuations an...

7.1AI score
SaveExploits0
Positive Technologies
Positive Technologies
added 2025/08/12 12:0 a.m.11 views

PT-2025-32892 · Schneider Electric · Ecostruxure Power Monitoring Expert +1

Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert versions affected versions not specified Description: A Server-Side Request Forgery SSRF vulnerability exists that could cause unauthorized access to sensitive data when an attacker...

7.5CVSS5.9AI score0.00451EPSS
SaveExploits0References7
Zero Day Initiative
Zero Day Initiative
added 2025/08/12 12:0 a.m.14 views

(0Day) Schneider Electric EcoStruxure Power Monitoring Expert HttpPostedFile Directory Traversal Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The specific flaw exists within the HttpPostedFile module. The issue results from the...

7.2CVSS7.7AI score0.00595EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:0 a.m.4 views

Linux Distros Unpatched Vulnerability : CVE-2022-50011

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - venus: pmhelpers: Fix warning in OPP during probe Fix the following WARN triggered during Venus driver probe on 5.19.0-rc8-next-20220728: WARNING: CPU: 7 PID: 3...

5.5CVSS6.1AI score0.00208EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:0 a.m.14 views

Linux Distros Unpatched Vulnerability : CVE-2023-52645

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - In the Linux kernel, the following vulnerability has been resolved: pmdomain: mediatek: fix race conditions with genpd If the power domains are registered first...

4.7CVSS5.4AI score0.00173EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:0 a.m.4 views

Linux Distros Unpatched Vulnerability : CVE-2022-49841

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - In the Linux kernel, the following vulnerability has been resolved: serial: imx: Add missing .thawnoirq hook The following warning is seen with non-console UART...

5.5CVSS5.6AI score0.00189EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2025/08/12 12:0 a.m.16 views

PT-2025-32890 · Schneider Electric · Ecostruxure Power Monitoring Expert

Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: The software contains a deserialization of untrusted data flaw within the GetFilteredSinkProvider component, potentially leading to remote cod...

9CVSS7.5AI score0.00668EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
added 2025/08/12 12:0 a.m.11 views

PT-2025-32894 · Schneider Electric · Ecostruxure Power Monitoring Expert

Name of the Vulnerable Software and Affected Versions: Schneider Electric EcoStruxure Power Monitoring Expert affected versions not specified Description: This issue involves a directory traversal vulnerability within the HttpPostedFile functionality of Schneider Electric EcoStruxure Power...

4.9CVSS7.5AI score0.00595EPSS
SaveExploits0References6
Zero Day Initiative
Zero Day Initiative
added 2025/08/12 12:0 a.m.16 views

(0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetPagesAsImages Server-Side Request Forgery Information Disclosure Vulnerability

This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is not required to exploit this vulnerability. The specific flaw exists within the GetPagesAsImages method. The issue...

7.5CVSS6.4AI score0.00455EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2025/08/12 12:0 a.m.9 views

Siemens POWER METER SICAM Q100和Siemens POWER METER SICAM Q200 安全漏洞

Siemens POWER METER SICAM Q100 and Siemens POWER METER SICAM Q200 are multifunctional power quality recorders from Siemens, Germany. A security vulnerability exists in Siemens POWER METER SICAM Q100 and Siemens POWER METER SICAM Q200 prior to version V2.62, which stems from the plaintext storage ...

6.8CVSS6.5AI score0.00092EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2025/08/12 12:0 a.m.20 views

(0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetFilteredSinkProvider Deserialization of Untrusted Data Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The specific flaw exists within the implementation of the GetFilteredSinkProvider...

8.8CVSS7.8AI score0.00668EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:0 a.m.5 views

Linux Distros Unpatched Vulnerability : CVE-2025-38360

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - drm/amd/display: Add more checks for DSC / HUBP ONO guarantees WHY For non-zero DSC instances it's possible that the HUBP domain required to drive it for...

5.5CVSS6.1AI score0.00157EPSS
SaveExploits0References2
Zero Day Initiative
Zero Day Initiative
added 2025/08/12 12:0 a.m.15 views

(0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetTgmlContent Directory Traversal Information Disclosure Vulnerability

This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The specific flaw exists within the GetTgmlContent method. The issue results...

4.9CVSS6.4AI score0.00908EPSS
SaveExploits0References2
Rows per page
Query Builder