Lucene search
+L

55 matches found

CNVD
CNVD
added 2017/02/10 12:0 a.m.5 views

BINOM3 Electric Power Quality Meter Cross-Site Scripting Vulnerability

BINOM3 Electric Power Quality Meter is an electrical power quality monitor for SCADA systems from the Russian company BINOM3. A cross-site scripting vulnerability exists in BINOM3 Electric Power Quality Meter that could allow an attacker to execute arbitrary script code cross-site scripting withi...

6.1CVSS6.7AI score0.00825EPSS
SaveExploits0References1
CNVD
CNVD
added 2017/02/10 12:0 a.m.5 views

BINOM3 Electric Power Quality Meter Unauthorized Operation Vulnerability

BINOM3 Electric Power Quality Meter is an electrical power quality monitor for SCADA systems from the Russian company BINOM3. An unauthorized operation vulnerability exists in BINOM3 Electric Power Quality Meter, which could be exploited by an attacker to perform unauthorized operations on the...

7.6CVSS6.8AI score0.00665EPSS
SaveExploits0References1
CNVD
CNVD
added 2017/02/10 12:0 a.m.7 views

BINOM3 Electric Power Quality Meter Hard-Coded Vulnerability

BINOM3 Electric Power Quality Meter is an electrical power quality monitor for SCADA systems from the Russian company BINOM3. A hard-coded vulnerability exists in BINOM3 Electric Power Quality Meter, where users do not have permission to change their passwords...

8.6CVSS6.8AI score0.01356EPSS
SaveExploits0References1
CNVD
CNVD
added 2017/02/10 12:0 a.m.5 views

BINOM3 Electric Power Quality Meter Information Disclosure Vulnerability

BINOM3 Electric Power Quality Meter is an electrical power quality monitor for SCADA systems from the Russian company BINOM3. An information disclosure vulnerability exists in BINOM3 Electric Power Quality Meter that could be exploited by an attacker to provide remote services with access to...

10CVSS6.4AI score0.1261EPSS
SaveExploits2References1
ICS
ICS
added 2017/01/31 12:0 a.m.62 views

BINOM3 Electric Power Quality Meter

CVSS v3 10 ATTENTION: Remotely exploitable/low skill level to exploit Vendor: BINOM3 Equipment: Electric Power Quality Meter Vulnerabilities: Cross-site scripting, access control issues, cross-site request forgery CSRF, sensitive information stored in clear-text, and weak credentials management...

10CVSS1.6AI score0.1261EPSS
SaveExploits2References38
ICS
ICS
added 2017/01/31 12:0 a.m.46 views

BINOM3 Electric Power Quality Meter (Update A)

CVSS v3 10 ATTENTION: Remotely exploitable/low skill level to exploit Vendor: BINOM3 Equipment: Electric Power Quality Meter Vulnerabilities: Cross-site scripting, access control issues, cross-site request forgery CSRF, sensitive information stored in clear-text, and weak credentials management...

10CVSS9.2AI score0.1261EPSS
SaveExploits2References3
CNVD
CNVD
added 2016/09/18 12:0 a.m.3 views

BINOM3 Electric Power Quality Meter Sensitive Information Disclosure Vulnerability

The BINOM3 Electric Power Quality Meter is a universal multifunctional power quality monitor. BINOM3 Electric Power Quality Meter is vulnerable to sensitive information disclosure. Since the management portal is configured for HTTP by default, an attacker in the right position could sniff all log...

6.8AI score
SaveExploits0References1
CNVD
CNVD
added 2016/09/18 12:0 a.m.2 views

BINOM3 Electric Power Quality Meter Stores Sensitive Information Vulnerability

The BINOM3 Electric Power Quality Meter is a universal multifunctional power quality monitor. A vulnerability exists in the storage of sensitive information in the BINOM3 Electric Power Quality Meter. An attacker could exploit the vulnerability to gain privileged access to the device...

6.7AI score
SaveExploits0References1
CNVD
CNVD
added 2016/09/18 12:0 a.m.3 views

BINOM3 Electric Power Quality Meter Cross-Site Request Forgery Vulnerability

The BINOM3 Electric Power Quality Meter is a universal multifunctional power quality monitor. A cross-site request forgery vulnerability exists in BINOM3 Electric Power Quality Meter. Exploitation of this vulnerability could allow unauthorized actions on the device, such as configuration paramete...

6.8AI score
SaveExploits0References1
CNVD
CNVD
added 2016/09/18 12:0 a.m.7 views

BINOM3 Electric Power Quality Meter Weak Password Vulnerability

The BINOM3 Electric Power Quality Meter is a universal multifunctional power quality monitor. The BINOM3 Electric Power Quality Meter is vulnerable to a weak password. The device is configured with four login accounts "admin / 1", "user / 1", "alg / 1", "telem / 1". To further make it easier for...

7AI score
SaveExploits0References1
Packet Storm
Packet Storm
added 2016/09/16 12:0 a.m.43 views

BINOM3 Power Meter CSRF / XSS / Credential Management

Universal multifunctional Electric Power Quality Meter BINOM3 - Multiple Vulnerabilities About The meters are designed for autonomous operation in automated systems: aC/ SCADA systems aC/ Data aquisition and transmission systems aC/ Automated data and measurement systems for revenue and technical...

0.2AI score
SaveExploits0
CNVD
CNVD
added 2015/10/30 12:0 a.m.5 views

Janitza UMG Arbitrary File Read/Write Vulnerability (CNVD-2015-07286)

The Janitza UMG is an online power quality monitor for the energy industry from Janitza Germany. An arbitrary file read/write vulnerability exists in Janitza UMG 508, 509, 511, 604, 605. This allows remote attackers to read or write files via a TCP session on port 21...

7.5CVSS7AI score0.02266EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/10/30 12:0 a.m.7 views

Janitza UMG has multiple cross-site scripting vulnerabilities

The Janitza UMG is an online power quality monitor for the energy industry from Janitza Germany. The Janitza UMG 508, 509, 511, 604, 605, suffers from multiple cross-site scripting vulnerabilities. This allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...

4.3CVSS6.2AI score0.01142EPSS
SaveExploits0References1
ICS
ICS
added 2015/06/25 6:0 a.m.74 views

Janitza UMG Power Quality Measuring Products Vulnerabilities

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on September 22, 2015, and is being released to the NCCIC/ICS-CERT web site. Mattijs van Ommeren of Applied Risk has identified several vulnerabilities in the Janitza UMG power quality measuring products. Janitza ha...

10CVSS7.2AI score0.02858EPSS
SaveExploits0References10
Packet Storm
Packet Storm
added 2013/12/07 12:0 a.m.33 views

Eaton Network Shutdown Module 3.21 PHP Code Injection

!/usr/bin/env python Quick 'n' Dirty - Metasploit module didn't do it for me 2013 - Filip Waeytens - http://www.wsec.be Usage Example: $ python eaton.py 192.168.1.9 "net user" User accounts for \ ------------------------------------------------------------------------------- Guest LocalAdmin The...

0.1AI score
SaveExploits0
Rows per page