Lucene search
+L

21 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/26 12:00 a.m.•13 views

CVE-2026-9523: Improper Neutralization of Special Elements used in an SQL Command

A vulnerability was detected in Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform 3000WEBV2. Affected by this vulnerability is an unknown functionality of the file /SubstationWEBV2/app/..;/calc/getCalcmeterDetailDayListTree. Performing a manipulation of the argument...

7.5CVSS7.1AI score0.0033EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/26 12:00 a.m.•18 views

CVE-2026-9550: Improper Limitation of a Pathname to a Restricted Directory

A vulnerability was determined in Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform 1.3.0. Affected by this issue is some unknown functionality of the file /SubstationWEBV2/app/..;/main/upfile. Executing a manipulation of the argument path can lead to path traversal...

7.5CVSS6.9AI score0.00519EPSS
SaveExploits0References2
EUVD
EUVD
•added 2026/05/03 12:30 p.m.•30 views

EUVD-2026-26834

A vulnerability was found in Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform 1.3.0. This impacts an unknown function of the file /SubstationWEBV2/main/uploadH5Files. The manipulation of the argument File results in unrestricted upload. The attack may be launched...

6.5CVSS6.2AI score0.00224EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
•added 2026/05/03 12:15 p.m.•24 views

CVE-2026-7695 Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform elecMaxMinAvgValue sql injection

A vulnerability has been found in Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform 1.3.0. This affects an unknown function of the file /SubstationWEBV2/main/elecMaxMinAvgValue. The manipulation of the argument fCircuitids leads to sql injection. The attack may be...

7.5CVSS6.9AI score0.00343EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/03 12:00 a.m.•17 views

CVE-2026-7695: Improper Neutralization of Special Elements used in an SQL Command

A vulnerability has been found in Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform 1.3.0. This affects an unknown function of the file /SubstationWEBV2/main/elecMaxMinAvgValue. The manipulation of the argument fCircuitids leads to sql injection. The attack may be...

7.5CVSS7AI score0.00343EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/05/03 12:00 a.m.•15 views

CVE-2026-7696: Unrestricted Upload of File with Dangerous Type

A vulnerability was found in Acrel Electrical EEMS Enterprise Power Operation and Maintenance Cloud Platform 1.3.0. This impacts an unknown function of the file /SubstationWEBV2/main/uploadH5Files. The manipulation of the argument File results in unrestricted upload. The attack may be launched...

6.5CVSS6.3AI score0.00224EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2026/03/10 12:00 a.m.•29 views

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation (Schneider Electric EPO) code-related vulnerabilities

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation Schneider Electric EPO are both products of Schneider Electric, a French company. Schneider Electric EcoStruxure Power Monitoring Expert is a device used for power distribution monitoring in...

8.5CVSS8AI score0.00216EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2025/09/01 12:00 a.m.•26 views

EcoStruxure Power Monitoring Expert Path Traversal

The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software lies in the incorrect restriction on the path to the restricted-access catalog. Exploiting this vulnerability could allow a malicious actor, operating remotely, to gain unauthorized access to protected...

6.8CVSS7.4AI score0.00743EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
•added 2025/09/01 12:00 a.m.•27 views

EcoStruxure Power Monitoring Expert Information Disclosure

The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software lies in the ability to disclose information in the erroneous data range. Exploiting this vulnerability can allow an attacker operating remotely to gain unauthorized access to protected information...

4.3CVSS6.4AI score0.00333EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2025/09/01 12:00 a.m.•22 views

EcoStruxure Power Monitoring Expert Path Traversal

The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software lies in the incorrect restriction of the path name to the restricted access catalog. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code remotely...

9CVSS7.1AI score0.01083EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
•added 2025/08/27 12:00 a.m.•22 views

EcoStruxure Power Monitoring Expert SSRF

The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software-related programs is related to insufficient checking of requests on the server side. Exploiting this vulnerability can allow a malicious actor to execute an SSRF attack remotely...

7.8CVSS7.9AI score0.00563EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
•added 2025/08/27 12:00 a.m.•28 views

EcoStruxure Power Monitoring Expert SRF

The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software-related programs is related to insufficient checking of requests on the server side. Exploiting this vulnerability can allow a malicious actor to execute an SSRF attack remotely...

7.8CVSS7.9AI score0.00563EPSS
SaveExploits0References3Affected Software1
CNNVD
CNNVD
•added 2025/08/20 12:00 a.m.•27 views

Schneider Electric EcoStruxure Power Monitoring Expert and EcoStruxure Power Operation Advanced Reporting and Dashboard Module code-related vulnerabilities

Schneider Electric EcoStruxure Power Monitoring Expert and EcoStruxure Power Operation AdvancedReporting and Dashboards Module are products of Schneider Electric, France. Schneider Electric EcoStruxure Power Monitoring Expert is a device for power distribution monitoring in IoT...

8.7CVSS8.3AI score0.00809EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2025/08/20 12:00 a.m.•25 views

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation have vulnerabilities related to path traversal.

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation Schneider Electric EPO are both products of the French company Schneider Electric Schneider Electric EcoStruxure Power Monitoring Expert is an appliance for power distribution monitoring in I...

7.2CVSS6.6AI score0.01083EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
•added 2025/08/13 12:00 a.m.•23 views

EcoStruxure Power Monitoring Expert Deserialization

The vulnerability of the EcoStruxure Power Monitoring Expert and Power Operation software is related to deficiencies in the deserialization mechanism. Exploiting this vulnerability could allow a remote attacker to compromise the confidentiality, integrity, and accessibility of the protected...

9CVSS8.8AI score0.00809EPSS
SaveExploits0References3Affected Software1
CISA
CISA
•added 2025/07/22 12:00 p.m.•35 views

CISA Releases Nine Industrial Control Systems Advisories

CISA released nine Industrial Control Systems ICS advisories on July 22, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-203-01 DuraComm DP-10iN-100-MU ICSA-25-203-02 Lantronix Provisioning Manager...

7AI score
SaveExploits0References9
CNNVD
CNNVD
•added 2025/07/11 12:00 a.m.•23 views

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation have security vulnerabilities

Schneider Electric EcoStruxure Power Monitoring Expert and Schneider Electric EcoStruxure Power Operation Schneider Electric EPO are both products of the French company Schneider Electric Schneider Electric EcoStruxure Power Monitoring Expert is a device for power distribution monitoring in IoT...

5.3CVSS5.4AI score0.00333EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2024/11/15 12:00 a.m.•28 views

Power Monitoring Expert XSS

The vulnerability of the Power Monitoring Expert, Power Operation, and Power SCADA Operation software relates to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a malicious actor to carry out XSS attacks from a remote location...

5.5CVSS6.6AI score0.00306EPSS
SaveExploits0References3Affected Software1
Positive Technologies
Positive Technologies
•added 2024/09/10 12:00 a.m.•43 views

PT-2024-8122 · Unknown · Power Scada Operation +2

Name of the Vulnerable Software and Affected Versions: Power Monitoring Expert, Power Operation, Power SCADA Operation affected versions not specified Description: The issue is related to improper neutralization of input during web page generation, also known as Cross-site Scripting XSS. This...

5.5CVSS5.8AI score0.00306EPSS
SaveExploits0References7
BDU FSTEC
BDU FSTEC
•added 2023/11/15 12:00 a.m.•23 views

EcoStruxure PowerSCADA Operation Advanced Reporting and Dashboards Module URL Redirection

The vulnerability of the software used for creating control panels for energy management systems, such as EcoStruxure PowerSCADA Operation PSO – Advanced Reporting and Dashboards Module, EcoStruxure PowerOperation EPO – Advanced Reporting and Dashboards Module, and the energy monitoring software...

9.4CVSS6.9AI score0.00534EPSS
SaveExploits0References2
Rows per page
Query Builder