Lucene search
+L

120 matches found

NVD
NVD
added 2022/01/28 8:15 p.m.19 views

CVE-2021-22827

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions...

8.8CVSS0.01201EPSS
SaveExploits0References1
OSV
OSV
added 2022/01/28 8:15 p.m.6 views

CVE-2021-22826

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions...

8.8CVSS7.8AI score0.01201EPSS
SaveExploits0References1
Prion
Prion
added 2022/01/28 8:15 p.m.17 views

Input validation

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions...

6.8CVSS8.9AI score0.01201EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2022/01/28 8:15 p.m.22 views

Input validation

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure? Power Monitoring Expert 9.0 and prior versions...

6.8CVSS8.9AI score0.01201EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/01/28 7:9 p.m.68 views

CVE-2021-22827

CVE-2021-22827 corresponds to an improper input validation (CWE-20) vulnerability in EcoStruxure Power Monitoring Expert 9.0 and earlier. Red Hat entries corroborate that this flaw could lead to arbitrary code execution when a user visits a page containing the injected payload; this CVE is distin...

8.8CVSS8.8AI score0.01201EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/01/28 7:9 p.m.94 views

CVE-2021-22826

The connected Red Hat entries confirm CVE-2021-22826 is an input-validation flaw (CWE-20) in EcoStruxure Power Monitoring Expert 9.0 and earlier. The vulnerability allows arbitrary code execution when a user visits a page containing the injected payload. The issue is tied to CVE-2021-22827 as a s...

8.8CVSS8.8AI score0.01201EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/01/28 12:0 a.m.5 views

Schneider Electric EcoStruxure Power Monitoring Expert 输入验证错误漏洞

Schneider Electric EcoStruxure Power Monitoring Expert is a device from Schneider Electric France for power distribution monitoring in IoT environments. An input validation error vulnerability exists in Schneider Electric EcoStruxure Power Monitoring Expert version 9.0 and prior versions, which...

8.8CVSS8.3AI score0.01201EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2022/01/28 12:0 a.m.5 views

PT-2022-9295 · Schneider Electric · Ecostruxure Power Monitoring Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure Power Monitoring Expert versions 9.0 and prior Description: A vulnerability exists due to improper input validation, which could lead to arbitrary code execution when a user visits a page containing a malicious payload...

8.8CVSS8.8AI score0.01201EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2022/01/28 12:0 a.m.6 views

Schneider Electric EcoStruxure Power Monitoring Expert 输入验证错误漏洞

Schneider Electric EcoStruxure Power Monitoring Expert is a device from Schneider Electric France for power distribution monitoring in IoT environments. An input validation error vulnerability exists in Schneider Electric EcoStruxure Power Monitoring Expert version 9.0 and prior versions, which...

8.8CVSS8.3AI score0.01201EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2022/01/11 12:0 a.m.9 views

PT-2022-6396 · Schneider Electric · Ecostruxure Power Monitoring Expert

Name of the Vulnerable Software and Affected Versions: EcoStruxure Power Monitoring Expert versions 2020 and prior Description: The issue is related to insufficient input validation, which could allow a remote attacker to view and modify equipment settings. An unauthenticated attacker may be able...

9.3CVSS8.4AI score0.01235EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
added 2021/08/26 12:0 a.m.7 views

The vulnerability of the software for power monitoring systems such as Power Monitoring Expert, EcoStruxure Energy Expert, Power Manager, data collection systems, and industrial automation control systems like StruxureWare PowerSCADA Expert, related to access control deficiencies, allows attackers to exploit these vulnerabilities to gain increased privileges.

The vulnerabilities of the Power Monitoring Expert, EcoStruxure Energy Expert, Power Manager software, as well as systems for data collection and process control in industrial automation, such as StruxureWare PowerSCADA Expert, are related to lack of access control mechanisms. Exploiting these...

6.5CVSS7.6AI score0.01298EPSS
SaveExploits0References2Affected Software5
NVD
NVD
added 2020/12/01 3:15 p.m.31 views

CVE-2020-7547

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow a user the ability to perform actions via the web interface at a higher privilege level...

8.8CVSS8.7AI score0.01298EPSS
SaveExploits0References1
OSV
OSV
added 2020/12/01 3:15 p.m.5 views

CVE-2020-7547

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow a user the ability to perform actions via the web interface at a higher privilege level...

8.8CVSS5.8AI score0.01298EPSS
SaveExploits0References1
NVD
NVD
added 2020/12/01 3:15 p.m.31 views

CVE-2020-7545

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow for arbitrary code execution on the server when an authorized user access an affected webpage...

7.2CVSS7.4AI score0.01995EPSS
SaveExploits0References1
OSV
OSV
added 2020/12/01 3:15 p.m.8 views

CVE-2020-7545

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow for arbitrary code execution on the server when an authorized user access an affected webpage...

7.2CVSS7.5AI score0.01995EPSS
SaveExploits0References1
NVD
NVD
added 2020/12/01 3:15 p.m.28 views

CVE-2020-7546

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow an attacker to perform actions on behalf of the authorized user when...

5.4CVSS5.5AI score0.00617EPSS
SaveExploits0References1
OSV
OSV
added 2020/12/01 3:15 p.m.5 views

CVE-2020-7546

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow an attacker to perform actions on behalf of the authorized user when...

5.4CVSS6.1AI score0.00617EPSS
SaveExploits0References1
Prion
Prion
added 2020/12/01 3:15 p.m.22 views

Design/Logic Flaw

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow an attacker to perform actions on behalf of the authorized user when...

3.5CVSS5.5AI score0.00617EPSS
SaveExploits0References1Affected Software5
Prion
Prion
added 2020/12/01 3:15 p.m.25 views

Improper access control

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software see security notification for version information that could allow a user the ability to perform actions via the web interface at a higher privilege level...

6.5CVSS8.6AI score0.01298EPSS
SaveExploits0References1Affected Software5
CVE
CVE
added 2020/12/01 2:44 p.m.58 views

CVE-2020-7547

CVE-2020-7547 concerns an improper access control vulnerability in Schneider Electric EcoStruxure and SmartStruxure Power Monitoring and SCADA Software. The common description across sources states that a user can perform actions via the web interface at a higher privilege level, indicating privi...

8.8CVSS8.6AI score0.01298EPSS
SaveExploits0References1Affected Software5
Rows per page
Query Builder