32 matches found
Command injection
OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/settimezone timezone parameter, because of settimezone in models/managementmodel.php...
CVE-2023-28343: Improper Neutralization of Special Elements used in an OS Command
OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/settimezone timezone parameter, because of settimezone in models/managementmodel.php...
CVE-2023-28343
OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/settimezone timezone parameter, because of settimezone in models/managementmodel.php...
CVE-2023-28343
Altenergy Power Control Software C1.2.5 is affected by CVE-2023-28343: an OS command injection via shell metacharacters in the index.php/management/set_timezone parameter, caused by set_timezone in models/management_model.php. This allows remote command execution with the affected product version...
APsystems Access Control Error Vulnerability
APsystems is a microinverter from APsystems, Inc. Combining high efficiency power conversion with a user-friendly monitoring interface, it brings you reliable and smart energy. An access control error vulnerability exists in APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software version...
CVE-2022-44037
An access control issue in APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software V4.1NA, V3.11.4, W2.1NA, V4.1SAA, C1.2.2 allows attackers to access sensitive data and execute specific commands and functions with full admin rights without authenticating allows him to perform multiple...
Design/Logic Flaw
An access control issue in APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software V4.1NA, V3.11.4, W2.1NA, V4.1SAA, C1.2.2 allows attackers to access sensitive data and execute specific commands and functions with full admin rights without authenticating allows him to perform multiple...
CVE-2022-44037
An access control issue in APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software V4.1NA, V3.11.4, W2.1NA, V4.1SAA, C1.2.2 allows attackers to access sensitive data and execute specific commands and functions with full admin rights without authenticating allows him to perform multiple...
CVE-2022-44037: Improper Access Control
An access control issue in APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software V4.1NA, V3.11.4, W2.1NA, V4.1SAA, C1.2.2 allows attackers to access sensitive data and execute specific commands and functions with full admin rights without authenticating allows him to perform multiple...
APsystems security vulnerabilities
APsystems is a microinverter from APsystems, Inc. Combining high efficiency power conversion with a user-friendly monitoring interface, it brings you reliable and smart energy. An access control error vulnerability exists in APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software version...
CVE-2022-44037
CVE-2022-44037 refers to an improper access control flaw in APsystems ENERGY COMMUNICATION UNIT (ECU-C) Power Control Software (versions V4.1NA, V3.11.4, W2.1NA, V4.1SAA, C1.2.2) that allows attackers to access sensitive data and execute commands with full admin rights without authentication. The...
PT-2022-7248 · Apsystems · Apsystems Energy Communication Unit (Ecu-C) Power Control
Name of the Vulnerable Software and Affected Versions: APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software versions V3.11.4, V4.1NA, V4.1SAA, W2.1NA, C1.2.2 Description: An access control issue in the APsystems ENERGY COMMUNICATION UNIT ECU-C Power Control Software allows attackers t...