Lucene search
+L

9139 matches found

Positive Technologies
Positive Technologies
added 2025/08/13 12:00 a.m.19 views

PT-2025-32981 · Zkteco · Zkteco Wl20

Name of the Vulnerable Software and Affected Versions: ZKTeco WL20 affected versions not specified Description: The device stores a private key in plaintext within its firmware. An attacker with physical access can extract the firmware, analyze the binary data, and retrieve the private key...

6.9CVSS6.4AI score0.00174EPSS
SaveExploits0References5
Cvelist
Cvelist
added 2025/08/12 11:17 a.m.18 views

CVE-2025-40753

A vulnerability has been identified in POWER METER SICAM Q100 7KG9501-0AA01-0AA1 All versions = V2.60 = V2.60 = V2.60 = V2.60 = V2.70 V2.80. Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extra...

6.8CVSS0.00095EPSS
SaveExploits0References1
CVE
CVE
added 2025/08/12 11:17 a.m.35 views

CVE-2025-40752

CVE-2025-40752 affects Siemens POWER METER SICAM Q100/Q200 (Q100 variants 2.60–2.61/2.60–2.61 for certain SKUs) and SICAM Q200 (2.70–2.79) where SMTP password is stored in cleartext. This allows an authenticated local attacker to read the SMTP credentials from the device configuration and abuse t...

6.8CVSS7AI score0.00095EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:00 a.m.5 views

Linux Distros Unpatched Vulnerability : CVE-2025-49087

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - In Mbed TLS 3.6.1 through 3.6.3 before 3.6.4, a timing discrepancy in block cipher padding removal allows an attacker to recover the plaintext when PKCS7 paddin...

4CVSS5.9AI score0.00395EPSS
SaveExploits1References2
CNNVD
CNNVD
added 2025/08/12 12:00 a.m.12 views

Siemens POWER METER SICAM Q100和Siemens POWER METER SICAM Q200 安全漏洞

Siemens POWER METER SICAM Q100 and Siemens POWER METER SICAM Q200 are multifunctional power quality recorders from Siemens, Germany. A security vulnerability exists in Siemens POWER METER SICAM Q100 and Siemens POWER METER SICAM Q200 prior to version V2.62, which stems from the plaintext storage ...

6.8CVSS6.5AI score0.00095EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2025/08/12 12:00 a.m.6 views

Linux Distros Unpatched Vulnerability : CVE-2018-0497

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - ARM mbed TLS before 2.12.0, before 2.7.5, and before 2.1.14 allows remote attackers to achieve partial plaintext recovery for a CBC based ciphersuite via a...

5.9CVSS6.7AI score0.02674EPSS
SaveExploits0References2
RedhatCVE
RedhatCVE
added 2025/08/10 4:29 p.m.19 views

CVE-2025-52586

The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write...

7.5CVSS7.2AI score0.00079EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2025/08/10 12:00 a.m.6 views

Linux Distros Unpatched Vulnerability : CVE-2020-36476

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - An issue was discovered in Mbed TLS before 2.24.0 and before 2.16.8 LTS and before 2.7.17 LTS. There is missing zeroization of plaintext buffers in mbedtlssslre...

7.5CVSS7AI score0.0157EPSS
SaveExploits0References2
OSV
OSV
added 2025/08/08 9:32 p.m.9 views

CVE-2025-8741 macrozheng mall login cleartext transmission

A vulnerability was found in macrozheng mall up to 1.0.3. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file /admin/login. The manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. The...

6.3CVSS4.4AI score
SaveExploits0References7
NVD
NVD
added 2025/08/08 4:15 p.m.15 views

CVE-2025-52586

The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write...

7.5CVSS0.00079EPSS
SaveExploits0References3
CVE
CVE
added 2025/08/08 4:00 p.m.36 views

CVE-2025-52586

The CVE-2025-52586 issue affects EG4 Electronics EG4 Inverters, where MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext. The root impact described across sources is interception, manipulation, replay, or forging of sensitive commands/data (voltag...

7.5CVSS6.4AI score0.00079EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2025/08/08 4:00 p.m.25 views

CVE-2025-52586 EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information

The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write...

7.5CVSS0.00079EPSS
SaveExploits0References3
RedhatCVE
RedhatCVE
added 2025/08/08 12:29 a.m.29 views

CVE-2025-54876

The Janssen Project is an open-source identity and access management IAM platform. In versions 1.9.0 and below, Janssen stores passwords in plaintext in the local clicmd.log file. This is fixed in the nightly prerelease...

6.9CVSS6.2AI score0.0046EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2025/08/08 12:00 a.m.4 views

Linux Distros Unpatched Vulnerability : CVE-2019-17005

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - The plain text serializer used a fixed-size array for the number of elements it could process; however it was possible to overflow the static-sized array leadin...

8.8CVSS7.3AI score0.01907EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
added 2025/08/08 12:00 a.m.26 views

PT-2025-32368

Name of the Vulnerable Software and Affected Versions: Inverter affected versions not specified Description: The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This may allow an attacker with access to a loca...

7.5CVSS6AI score0.00079EPSS
SaveExploits0References8
BDU FSTEC
BDU FSTEC
added 2025/08/08 12:00 a.m.17 views

The vulnerability of the Mbed TLS software lies in its use of hidden time channels for data transmission, which allows a hacker to recover the plaintext.

The vulnerability of Mbed TLS software is related to the use of hidden time channels for data transmission. Exploiting this vulnerability allows a remote attacker to recover the exposed text...

4CVSS5.3AI score0.00395EPSS
SaveExploits1References2Affected Software1
RedhatCVE
RedhatCVE
added 2025/08/07 12:31 a.m.26 views

CVE-2025-54870

VTun-ng is a Virtual Tunnel over TCP/IP network. In versions 3.0.17 and below, failure to initialize encryption modules might cause reversion to plaintext due to insufficient error handling. The bug was first introduced in VTun-ng version 3.0.12. This is fixed in version 3.0.18. To workaround thi...

8.7CVSS6.1AI score0.00199EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2025/08/07 12:00 a.m.3 views

Linux Distros Unpatched Vulnerability : CVE-2018-19608

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Arm Mbed TLS before 2.14.1, before 2.7.8, and before 2.1.17 allows a local unprivileged attacker to recover the plaintext of RSA decryption, which is used in...

4.7CVSS6.3AI score0.00339EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/07 12:00 a.m.4 views

Linux Distros Unpatched Vulnerability : CVE-2024-45004

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - In the Linux kernel, the following vulnerability has been resolved: KEYS: trusted: dcp: fix leak of blob encryption key Trusted keys unseal the key blob on load...

5.5CVSS5.4AI score0.00102EPSS
SaveExploits0References2
NVD
NVD
added 2025/08/06 12:15 a.m.10 views

CVE-2025-54876

The Janssen Project is an open-source identity and access management IAM platform. In versions 1.9.0 and below, Janssen stores passwords in plaintext in the local clicmd.log file. This is fixed in the nightly prerelease...

6.9CVSS0.0046EPSS
SaveExploits0References4
Rows per page
Query Builder