PT-2025-2402
Name of the Vulnerable Software and Affected Versions: Phoenix SecureCore for Intel Kaby Lake versions prior to 4.0.1.1012 Phoenix SecureCore for Intel Coffee Lake versions prior to 4.1.0.568 Phoenix SecureCore for Intel Comet Lake versions prior to 4.2.1.292 Phoenix SecureCore for Intel Ice Lake...
Phoenix SecureCore 代码问题漏洞
Phoenix SecureCore is a computer based input/output system from Phoenix Contact Phoenix of Germany. A code issue vulnerability exists in Phoenix SecureCore that arises from an improperly checked exception or anomaly that allows input data manipulation...
CVE-2024-29979: Improper Check for Unusual or Exceptional Conditions
Improper Check for Unusual or Exceptional Conditions vulnerability in Phoenix SecureCore™ for Intel Kaby Lake, Phoenix SecureCore™ for Intel Coffee Lake, Phoenix SecureCore™ for Intel Comet Lake, Phoenix SecureCore™ for Intel Ice Lake allows Input Data Manipulation.This issue affects SecureCore™...
Phoenix SecureCore 代码问题漏洞
Phoenix SecureCore is a computer based input/output system from Phoenix Contact Phoenix of Germany. A code issue vulnerability exists in Phoenix SecureCore that arises from an improperly checked exception or anomaly that allows input data manipulation...
BD多款产品 安全漏洞
BD BACTEC Blood Culture System and others are products of BD Medical BD, Inc. the BD BACTEC Blood Culture System is a blood culture media system. the BD COR System is a fully automated and integrated high-throughput diagnostic system. the BD EpiCenter Microbiology Data Management System is a...
Phoenix Contact ILC PLCs Improper Authentication (CVE-2016-8371)
The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Phoenix Contact ILC PLCs Cleartext Storage of Sensitive Information (CVE-2016-8366)
Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text. This plugin only works with...
Phoenix Contact PLCnext Improper Input Validation (CVE-2021-34570)
Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable,...
Phoenix Contact ILC PLCs Denial of Service (CVE-2021-33541)
Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of...
PHOENIX CONTACT PLCNext AXC F 2152 Improper Access Control (CVE-2019-10998)
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunit...
Phoenix Contact Classic Line Controllers Insufficient Verification of Data Authenticity (CVE-2022-31800)
An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Phoenix Contact ILC PLCs Improper Authentication (CVE-2016-8380)
The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if...
PHOENIX CONTACT PLCNext AXC F 2152 Channel Accessible By Non-Endpoint (CVE-2019-10997)
An issue was discovered on Phoenix Contact AXC F 2152 No.2404267 before 2019.0 LTS and AXC F 2152 STARTERKIT No.1046568 before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be...
Phoenix Contact Classic Line Industrial Controllers Missing Authentication For Critical Function (CVE-2019-9201)
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories. This plugin only works with Tenable.ot. Please visit...
Phoenix Contact PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...
The vulnerability of the binary file plctool of the microprogramming software for modular controllers of variable current charging stations and wall-mounted charging devices from Phoenix Contact, CHARX SEC-3100, allows a hacker to execute any code in the root context.
The vulnerability of the binary file of the microprogramming software for modular controllers of variable current charging stations and wall-mounted charging devices, the Phoenix Contact CHARX SEC-3100, exists due to insufficient verification of input data. Exploiting this vulnerability could all...
The vulnerability of the OCPP software-based modular controller systems for variable current charging stations and wall-mounted charging devices from Phoenix Contact CHARX SEC-3100 allows a perpetrator to gain unauthorized access and execute arbitrary codes.
The vulnerability of the OCPP microprogramming software for modular charge controllers for AC charging stations and wall-mounted charging devices from Phoenix Contact, CHARX SEC-3100, exists due to insufficient verification of input data. Exploiting this vulnerability can allow attackers to enhan...
The vulnerability of the CharxSystemConfigManager service in the microprogramming software for modular control devices for AC charging stations and wall-mounted charging devices from Phoenix Contact, CHARX SEC-3100, allows a hacker to execute arbitrary code.
The vulnerability of the CharxSystemConfigManager service in the microprogramming software for modular control devices for AC charging stations and wall-mounted charging devices from Phoenix Contact, the CHARX SEC-3100, is related to the absence of authentication procedures. Exploiting this...
The vulnerability of the CharxControllerAgent service in the microprogramming software for modular controllers for AC charging stations and wall-mounted charging devices from Phoenix Contact, CHARX SEC-3100, allows a intruder to execute arbitrary code.
The vulnerability of the CharxControllerAgent service in the microprogramming software for modular control devices for AC charging stations and wall-mounted charging devices from Phoenix Contact, the CHARX SEC-3100, is related to incomplete cleaning of temporary or auxiliary resources. Exploiting...
The vulnerability of the OCPP microprogramming software for modular control devices for DC charging stations and wall-mounted charging devices from Phoenix Contact CHARX SEC-3100 allows a intruder to execute arbitrary commands.
The vulnerability of the OCPP microprogramming software for modular control devices for DC charging stations and wall-mounted charging devices from Phoenix Contact’s CHARX SEC-3100 exists due to insufficient verification of input data. Exploiting this vulnerability could allow a malicious actor t...