Philips IntelliSpace Perinatal CVE-2019-13546 Local Security Bypass Vulnerability

Description Philips IntelliSpace Perinatal is prone to a local security-bypass vulnerability. Attackers can exploit this issue to bypass certain security restrictions to perform unauthorized actions. This may aid in further attacks. Philips IntelliSpace Perinatal versions K and prior are...

7.2CVSS1.4AI score0.00404EPSS
SaveExploits0References2
ICS
ICS
added 2019/10/24 12:0 a.m.127 views

Philips IntelliSpace Perinatal

1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION: Low skill level to exploit Vendor: Philips Equipment: IntelliSpace Perinatal Vulnerability: Exposure of Resource to Wrong Sphere 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker unauthorized access to system...

7.2CVSS6.8AI score0.00404EPSS
SaveExploits0References5
NVD
NVD
added 2019/09/12 8:15 p.m.16 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7.2CVSS7AI score0.01358EPSS
SaveExploits0References1
NVD
NVD
added 2019/09/12 8:15 p.m.15 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.2CVSS7.1AI score0.00687EPSS
SaveExploits0References1
OSV
OSV
added 2019/09/12 8:15 p.m.3 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7.2CVSS5.8AI score0.01358EPSS
SaveExploits0References1
Prion
Prion
added 2019/09/12 8:15 p.m.17 views

Code injection

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

6.5CVSS7AI score0.00687EPSS
SaveExploits0References1Affected Software4
Prion
Prion
added 2019/09/12 8:15 p.m.20 views

Design/Logic Flaw

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

6.5CVSS6.9AI score0.01358EPSS
SaveExploits0References1Affected Software4
Cvelist
Cvelist
added 2019/09/12 7:5 p.m.24 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7AI score0.01358EPSS
SaveExploits0References1
CVE
CVE
added 2019/09/12 7:5 p.m.156 views

CVE-2019-13530

CVE-2019-13530 affects Philips IntelliVue WLAN portable patient monitors. Affected products include MP20‑MP90 (WLAN Version A, Firmware A.03.09), MP5/5SC (A.03.09), MP2/X2 and MX800/700/600 (WLAN Version B, Firmware A.01.09). The root cause is hard-coded credentials enabling FTP login to upload a...

7.2CVSS7AI score0.01358EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2019/09/12 7:2 p.m.143 views

CVE-2019-13534

Philips IntelliVue WLAN portable patient monitors are affected by CVE-2019-13534. The vulnerability stems from the device downloading a file (code or firmware) from a remote location and executing it without sufficiently verifying the origin or integrity of the code. Affected products include Int...

7.2CVSS7.1AI score0.00687EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/09/12 7:2 p.m.28 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.1AI score0.00687EPSS
SaveExploits0References1
ICS
ICS
added 2019/09/12 12:0 a.m.94 views

Philips IntelliVue WLAN

1. EXECUTIVE SUMMARY CVSS v3 6.4 Vendor: Philips Equipment: IntelliVue M3002A X2 MMS Transport Monitor/Module and IntelliVue MP monitors MP2/X2, MP5, MP20-MP90, MX600, MX700 and MX800 Vulnerabilities: Use of Hard-coded Password, Download of Code Without Integrity Check 2. RISK EVALUATION...

7.2CVSS8AI score0.01358EPSS
SaveExploits0References5
NVD
NVD
added 2019/09/04 2:15 p.m.21 views

CVE-2019-10988

In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploit...

3.6CVSS3.9AI score0.00344EPSS
SaveExploits0References1
Prion
Prion
added 2019/09/04 2:15 p.m.16 views

Code injection

In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploit...

3.6CVSS3.9AI score0.00344EPSS
SaveExploits0References1
CVE
CVE
added 2019/09/04 1:36 p.m.78 views

CVE-2019-10988

Affected product: Philips HDI 4000 Ultrasound Systems (all versions on old, unsupported OS such as Windows 2000). Root cause: Use of obsolete function CWE-477 in the system’s software, enabling exploitation. Impact: CVSS v3 base score 3.0; potential exposure of ultrasound images and integrity com...

3.6CVSS4.1AI score0.00344EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/09/04 1:36 p.m.26 views

CVE-2019-10988

In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploit...

3.9AI score0.00344EPSS
SaveExploits0References1
CNVD
CNVD
added 2019/09/02 12:0 a.m.6 views

Unspecified Vulnerability in Philips HDI 4000 Ultrasound Systems

Philips HDI 4000 Ultrasound Systems is a set of ultrasound equipment for the medical industry from the European company Philips. A security vulnerability exists in the Philips HDI 4000 Ultrasound Systems running on older operating systems that are no longer supported, such as Windows 2000. An...

3.6CVSS6.6AI score0.00344EPSS
SaveExploits0References1
ICS
ICS
added 2019/08/29 12:0 a.m.72 views

Philips HDI 4000 Ultrasound

1. EXECUTIVE SUMMARY CVSS v3 3.0 ATTENTION: Public exploits are available/exploitable from within the same local subnet Vendor: Philips Equipment: HDI 4000 Ultrasound Systems Vulnerability: Use of Obsolete Function 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to...

3.6CVSS4.1AI score0.00344EPSS
SaveExploits0References5
NVD
NVD
added 2019/07/24 3:15 p.m.22 views

CVE-2019-10968

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled...

4.4CVSS4.7AI score0.00335EPSS
SaveExploits0References1
Prion
Prion
added 2019/07/24 3:15 p.m.18 views

Code injection

Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled...

2.1CVSS4.7AI score0.00335EPSS
SaveExploits0References1
Rows per page
Query Builder