added 2020/09/18 5:46 p.m.51 views

CVE-2020-14506

CVE-2020-14506 affects Philips Clinical Collaboration Platform (versions 12.2.1 and prior). The issue is a CSRF vulnerability stemming from improper input validation, allowing non-validated input to be used in processing and potentially enabling unauthorized actions when a user is authenticated. ...

4.3CVSS4.1AI score0.00288EPSS
SaveExploits0References2Affected Software1
CNVD
CNVD
added 2020/09/18 12:0 a.m.3 views

Philips Clinical Collaboration Platform Input Validation Error Vulnerability

Clinical Collaboration Platform is a clinical healthcare collaboration platform from Philips in the Netherlands. An input validation error vulnerability exists in Clinical Collaboration Platform version 12.2.1 and above. The vulnerability stems from the network system or product not properly...

3.5CVSS7AI score0.00472EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/09/18 12:0 a.m.5 views

Philips Clinical Collaboration Platform Cross-Site Request Forgery Vulnerability

Clinical Collaboration Platform is an HMI data management platform. A cross-site request forgery vulnerability exists in Clinical Collaboration Platform version 12.2.1 and earlier. An attacker can exploit this vulnerability to conduct cross-site request forgery attacks...

4.3CVSS6.9AI score0.00288EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/09/18 12:0 a.m.5 views

Philips Clinical Collaboration Platform Protection Mechanism Failure Vulnerability

Philips Clinical Collaboration Platform is an HMI data management platform. A protection mechanism failure vulnerability exists in Philips Clinical Collaboration Platform version 12.2.1 and earlier. The vulnerability stems from when an attacker claims to have a given identity, the software fails ...

6.3CVSS6.9AI score0.00564EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2020/09/18 12:0 a.m.6 views

PT-2020-14049 · Philips · Philips Clinical Collaboration Platform

Name of the Vulnerable Software and Affected Versions: Philips Clinical Collaboration Platform versions 12.2.1 and prior Description: The issue arises because the product does not properly validate input or data it receives, which can lead to incorrect processing. Recommendations: For versions...

4.3CVSS4.5AI score0.00288EPSS
SaveExploits0References4
CNVD
CNVD
added 2020/09/18 12:0 a.m.5 views

Philips Clinical Collaboration Platform Improper Access Control Vulnerability

Philips Clinical Collaboration Platform is an HMI data management platform. An improper access control vulnerability exists in Philips Clinical Collaboration Platform version 12.2.1 and earlier. An attacker could exploit the vulnerability to gain unauthorized access to resources...

7.1CVSS7AI score0.00361EPSS
SaveExploits0References1
ICS
ICS
added 2020/09/17 12:0 a.m.57 views

ICSMA-20-261-01_Philips Clinical Collaboration Platform

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Low skill level to exploit Vendor: Philips Equipment: Clinical Collaboration Platform Vulnerabilities: Cross-site Request Forgery, Improper Neutralization of Script in Attributes in a Web Page, Protection Mechanism Failure, Algorithm Downgrade,...

7.1CVSS6.4AI score0.00621EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 1:13 p.m.37 views

CVE-2020-16212 Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere

In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local...

6.3AI score0.00371EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 1:11 p.m.32 views

CVE-2020-16220 Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input

In Patient Information Center iX PICiX Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed i.e., to comply with a certain syntax but it does not validate or incorrectly validates that the input complies with the syntax,...

4.7AI score0.0028EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 1:6 p.m.38 views

CVE-2020-16216 Philips Patient Monitoring Devices Improper Input Validation

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and...

6.5AI score0.00698EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 1:5 p.m.38 views

CVE-2020-16224 Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency

In Patient Information Center iX PICiX Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to...

6.5AI score0.00594EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 12:58 p.m.32 views

CVE-2020-16228 Philips Patient Monitoring Devices Improper Check for Certificate Revocation

In Patient Information Center iX PICiX Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate...

6.4AI score0.00368EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 12:55 p.m.35 views

CVE-2020-16222 Philips Patient Monitoring Devices Improper Authentication

In Patient Information Center iX PICiX Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct...

8.7AI score0.00549EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/09/11 12:53 p.m.42 views

CVE-2020-16214 Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV File

In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value CSV file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadshee...

5.2AI score0.00586EPSS
SaveExploits0References2
ICS
ICS
added 2020/09/10 6:0 a.m.77 views

Philips Patient Monitoring Devices (Update C)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION : Low attack complexity Vendor : Philips Equipment : Patient Information Center iX PICiX; PerformanceBridge Focal Point; IntelliVue Patient Monitors MX100, MX400-MX850, and MP2-MP90; and IntelliVue X2, and X3 Vulnerabilities : Improper...

8.8CVSS7AI score0.00698EPSS
SaveExploits0References9
OSV
OSV
added 2020/08/31 3:15 p.m.6 views

CVE-2020-11618

THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol...

7.8CVSS7.2AI score0.00415EPSS
SaveExploits1References1
NVD
NVD
added 2020/08/31 3:15 p.m.27 views

CVE-2020-11618

THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol...

7.8CVSS7.5AI score0.00415EPSS
SaveExploits1References1
OSV
OSV
added 2020/08/31 3:15 p.m.7 views

CVE-2020-11617

The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client...

5.9CVSS6.3AI score0.0042EPSS
SaveExploits1References1
NVD
NVD
added 2020/08/31 3:15 p.m.23 views

CVE-2020-11617

The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client...

5.9CVSS5.6AI score0.0042EPSS
SaveExploits1References1
Prion
Prion
added 2020/08/31 3:15 p.m.17 views

Code injection

The RSS application on THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes doesn't validate the SSL certificates of RSS servers, which allows a man-in-the-middle attacker to modify the data delivered to the client...

4.3CVSS5.6AI score0.0042EPSS
SaveExploits1References1Affected Software2