CVE-2021-32966
Philips Interoperability Solution XDS versions 2.5 through 3.11 and 2018-1 through 2021-1 are vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDA...
CVE-2021-27456
Philips Gemini PET/CT family software stores sensitive information in a removable media device that does not have built-in access control...
CVE-2020-16237
Philips SureSigns VS4, A.07.107 and prior receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...
CVE-2020-14525
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users...
CVE-2020-14477
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require...
CVE-2020-6007
Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during the commissioning phase, resulting in a remote code execution...
CVE-2020-16247
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource...
CVE-2020-11618
THOMSON THT741FTA 2.2.1 and Philips DTR3502BFTA DVB-T2 2.2.1 set-top boxes have their TELNET service hardcoded to start on boot, which allows an attacker on the local network to achieve root access via the TELNET protocol...
CVE-2020-16241
Philips SureSigns VS4, A.07.107 and prior does not restrict or incorrectly restricts access to a resource from an unauthorized actor...
CVE-2020-14518
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker...
CVE-2020-16239
When an actor claims to have a given identity, Philips SureSigns VS4, A.07.107 and prior does not prove or insufficiently proves the claim is correct...
CVE-2020-27298
Philips Interventional Workspot Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5, Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live Release 1.0, ViewForum Release 6.3V1L10. The software constructs all or part of an OS command using externally influenced input from an upstream component but does no...
CVE-2020-16198
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct...
CVE-2020-16200
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources...
CVE-2020-14506
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...
CVE-2018-7580
Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding. The "hub" will stop operating and be frozen until the flood stops. During the flood, the user won't be able to turn on/off the lights, and all of...
CVE-2019-18263
An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity 718132 with wireless option shipped between 2016-August 2018, Veradius Unity 718132 with ViewForum option shipped between 2016-August 2018, Pulsera 718095 and Endura 718075 with wireless option shipp...
CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...
CVE-2019-6562
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...