Lucene search
+L

241 matches found

NVD
NVD
•added 2022/02/12 3:15 a.m.•33 views

CVE-2022-22765

BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...

8CVSS0.00231EPSS
SaveExploits0References2
Prion
Prion
•added 2022/02/12 3:15 a.m.•20 views

Hardcoded credentials

BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...

4.6CVSS7.3AI score0.00231EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2022/02/12 2:30 a.m.•42 views

CVE-2022-22765 BD Viper LT System - Hardcoded Credentials

BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...

8CVSS7.8AI score0.00231EPSS
SaveExploits0References2
CVE
CVE
•added 2022/02/12 2:30 a.m.•115 views

CVE-2022-22765

BD Viper LT system (BD) is affected for all versions 2.0 and later due to use of hard-coded credentials (CWE-798). The ICS advisory icsma-22-062-02 documents that an attacker could access, modify, or delete ePHI, PHI, and PII. The 4.0+ Windows 10 hardening in newer releases raises attack complexi...

8CVSS7.6AI score0.00231EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
•added 2022/02/12 12:00 a.m.•4 views

PT-2022-15658

Name of the Vulnerable Software and Affected Versions BD Viper LT system versions 2.0 through 3.x BD Viper LT system versions 4.0 and later Description The BD Viper LT system contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information,...

8CVSS0.00231EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/02/12 12:00 a.m.•8 views

CVE-2022-22765: Use of Hard-coded Credentials

BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...

8CVSS7.1AI score0.00231EPSS
SaveExploits0References3
Microsoft Secure
Microsoft Secure
•added 2021/02/04 7:00 p.m.•160 views

Automating and operationalizing data protection with Dataguise and Microsoft Information Protection

This blog post is part of the Microsoft Intelligent Security Association guest blog series. Learn more about MISA. In technical literature, the terms data discovery, classification, and tagging are sometimes used interchangeably, but there are real differences in what they actually mean—and each...

0.2AI score
SaveExploits0
ThreatPost
ThreatPost
•added 2020/12/08 5:00 p.m.•94 views

Critical, Unpatched Bug Opens GE Radiological Devices to Remote Code Execution

A pair of critical vulnerabilities have been discovered in dozens of GE Healthcare radiological devices popular in hospitals, which could allow an attacker to gain access to sensitive personal health information PHI, alter data and even shut the machine’s availability down. The flaws affect 100...

0.1AI score0.01502EPSS
SaveExploits0References9
NVD
NVD
•added 2020/12/03 4:15 p.m.•32 views

CVE-2020-28937

OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application, via a direct request for the /tests/ URI...

7.5CVSS7.6AI score0.01337EPSS
SaveExploits1References1
Prion
Prion
•added 2020/12/03 4:15 p.m.•27 views

Authentication flaw

OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application, via a direct request for the /tests/ URI...

5CVSS7.6AI score0.01337EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2020/12/03 3:54 p.m.•43 views

CVE-2020-28937

OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application, via a direct request for the /tests/ URI...

7.6AI score0.01337EPSS
SaveExploits1References1
CVE
CVE
•added 2020/12/03 3:54 p.m.•57 views

CVE-2020-28937

CVE-2020-28937 affects OpenClinic 0.8.2. A missing authentication issue allows unauthenticated users to access a patient’s medical test results via direct requests to the /tests/ URI, potentially exposing PHI. The vulnerability is highlighted in multiple sources (NVD entry, ThreatPost report) as ...

7.5CVSS7.5AI score0.01337EPSS
SaveExploits1References1Affected Software1
Mend
Mend
•added 2020/12/03 3:54 p.m.•2 views

CVE-2020-28937

OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application, via a direct request for the /tests/ URI...

8.7CVSS0.01337EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/03 12:00 a.m.•3 views

CVE-2020-28937: Missing Authentication for Critical Function

OpenClinic version 0.8.2 is affected by a missing authentication vulnerability that allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application, via a direct request for the /tests/ URI...

7.5CVSS5.9AI score0.01337EPSS
SaveExploits1References3
Positive Technologies
Positive Technologies
•added 2020/12/03 12:00 a.m.•1 views

PT-2020-17063

Name of the Vulnerable Software and Affected Versions OpenClinic version 0.8.2 Description The issue allows unauthenticated users to access any patient's medical test results, possibly resulting in disclosure of Protected Health Information PHI stored in the application. This can be done via a...

7.5CVSS0.01337EPSS
SaveExploits1References5
NVD
NVD
•added 2020/06/29 2:15 p.m.•27 views

CVE-2020-12016

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account...

10CVSS0.01856EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/29 2:15 p.m.•29 views

CVE-2020-12032

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI...

9.1CVSS0.00949EPSS
SaveExploits0References1
OSV
OSV
•added 2020/06/29 2:15 p.m.•15 views

CVE-2020-12016

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account...

9.8CVSS5.9AI score0.01856EPSS
SaveExploits0References1
OSV
OSV
•added 2020/06/29 2:15 p.m.•20 views

CVE-2020-12008

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI...

7.5CVSS7.1AI score0.00948EPSS
SaveExploits0References1
Prion
Prion
•added 2020/06/29 2:15 p.m.•21 views

Hardcoded credentials

Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...

3.6CVSS6.5AI score0.0036EPSS
SaveExploits0References1Affected Software2