Lucene search
+L

7 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•19 views

EUVD-2020-19765

Malware in sbrugna...

9.3CVSS8AI score0.0384EPSS
SaveExploits0References4
EUVD
EUVD
•added 2025/10/07 12:30 a.m.•13 views

EUVD-2020-17878

Malware in sbrugna...

10CVSS9.2AI score0.03931EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/14 12:00 a.m.•3 views

CVE-2020-25187: Heap-based Buffer Overflow

Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the...

10CVSS6.2AI score0.03931EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/14 12:00 a.m.•4 views

CVE-2020-27252: Time-of-check Time-of-use (TOCTOU) Race Condition

Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device...

9.3CVSS6AI score0.0384EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/12/14 12:00 a.m.•4 views

CVE-2020-25183: Improper Authentication

Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device ...

8.8CVSS5.9AI score0.00796EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2020/12/10 12:00 a.m.•25 views

Medtronic MyCareLink Smart Model 25000 Patient Reader Authorization Issue Vulnerability

The Medtronic MyCareLink Smart Model 25000 Patient Reader is a reader used in the healthcare industry to visually interact with medical devices from Medtronic, Inc. The Medtronic MyCareLink Smart Model 25000 Patient Reader is vulnerable to an authorization issue that could be used to bypass the...

8.8CVSS7.3AI score0.00796EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2020/12/10 12:00 a.m.•20 views

Medtronic MyCareLink Smart Model 25000 Patient Reader Buffer Error Vulnerability

The Medtronic MyCareLink Smart Model 25000 Patient Reader is a reader used in the healthcare industry to visually interact with medical devices from Medtronic, Inc. The Medtronic MyCareLink Smart Model 25000 Patient Reader suffers from a buffer error vulnerability that stems from the susceptibili...

10CVSS7.7AI score0.03931EPSS
SaveExploits0References5
Rows per page