Lucene search
+L

68 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/30 12:00 a.m.•1 views

CVE-2025-0683: Exposure of Private Personal Information to an Unauthorized Actor

In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a...

8.2CVSS8.1AI score0.00792EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2025/01/30 12:00 a.m.•9 views

Contec Health CMS8000 Patient Monitor 安全漏洞

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker can exploit the vulnerability to send specially formatted UDP requests to write arbitrary data...

9.8CVSS9.5AI score0.01288EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2025/01/30 12:00 a.m.•15 views

Contec Health CMS8000 Patient Monitor 安全漏洞

Contec Health CMS8000 Patient Monitor is a vital signs patient monitor from Contec Japan. A security vulnerability exists in the Contec Health CMS8000 Patient Monitor. An attacker could exploit the vulnerability to upload and overwrite files on the device...

7.7CVSS9.4AI score0.01149EPSS
SaveExploits0References5
ICS
ICS
•added 2022/09/01 6:00 a.m.•54 views

Contec Health CMS8000 Patient Monitor (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Low attack complexity Vendor: Contec Health Equipment: CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor Vulnerabilities: Improper Access Control, Uncontrolled Resource Consumption, Use of Hard-Coded Credentials, Active Debug Code 2. RISK EVALUATION...

7.5CVSS7AI score0.00974EPSS
SaveExploits0References10
NVD
NVD
•added 2019/01/28 10:29 p.m.•26 views

CVE-2018-19014

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the...

6.5CVSS6.9AI score0.00786EPSS
SaveExploits0References2
Prion
Prion
•added 2019/01/28 10:29 p.m.•30 views

Design/Logic Flaw

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the...

3.3CVSS6.8AI score0.00786EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2019/01/28 10:00 p.m.•40 views

CVE-2018-19014

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the...

6.7AI score0.00786EPSS
SaveExploits0References2
CVE
CVE
•added 2019/01/28 10:00 p.m.•60 views

CVE-2018-19014

CVE-2018-19014 affects Dräger Infinity Delta, Delta XL, Kappa, and Infinity Explorer C700 (all versions). The root issue is information exposure through log files: log data is accessible over an unauthenticated network connection, enabling an attacker to gain insights into internals of the patien...

6.5CVSS6.7AI score0.00786EPSS
SaveExploits0References2Affected Software1
Prion
Prion
•added 2018/08/10 6:29 p.m.•30 views

Authentication flaw

A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest...

1.9CVSS6.9AI score0.00364EPSS
SaveExploits0References2
NVD
NVD
•added 2018/08/10 6:29 p.m.•28 views

CVE-2018-10626

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLin...

4.4CVSS5.3AI score0.00364EPSS
SaveExploits0References5
NVD
NVD
•added 2018/08/10 6:29 p.m.•29 views

CVE-2018-10622

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication...

7.1CVSS7AI score0.00364EPSS
SaveExploits0References5
Cvelist
Cvelist
•added 2018/08/10 6:00 p.m.•35 views

CVE-2018-10626 Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLin...

4.4CVSS4.7AI score0.00364EPSS
SaveExploits0References4
CVE
CVE
•added 2018/08/10 6:00 p.m.•78 views

CVE-2018-10626

Medtronic MyCareLink 24950/24952 Patient Monitors are affected by CVE-2018-10626: the update service does not sufficiently verify data authenticity, enabling an attacker with per‑product credentials to upload invalid data to the CareLink network (CWE-345). Connected advisories corroborate affecte...

4.4CVSS6.1AI score0.00364EPSS
SaveExploits0References5Affected Software1
Cvelist
Cvelist
•added 2018/08/10 6:00 p.m.•36 views

CVE-2018-10622 Medtronic MyCareLink Patient Monitor Network Credential Weakness

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication...

5.2CVSS7AI score0.00364EPSS
SaveExploits0References4
CVE
CVE
•added 2018/08/10 6:00 p.m.•67 views

CVE-2018-10622

The CVE-2018-10622 issue affects Medtronic MyCareLink Patient Monitor models 24950/24952, where per-product credentials are stored in a recoverable format. This allows an attacker with physical access to obtain credentials and use them for network authentication and encryption of data at rest. Th...

7.1CVSS6.6AI score0.00364EPSS
SaveExploits0References5Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/10 12:00 a.m.•2 views

CVE-2018-10626: Insufficient Verification of Data Authenticity

Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLin...

4.4CVSS6AI score0.00364EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/10 12:00 a.m.•4 views

CVE-2018-10622: Cleartext Storage in a File or on Disk

Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication...

7.1CVSS6.3AI score0.00364EPSS
SaveExploits0References6
ICS
ICS
•added 2018/08/07 6:00 a.m.•71 views

Medtronic MyCareLink 24950 Patient Monitor (Update A)

1. EXECUTIVE SUMMARY CVSS v3 4.9 Vendor: Medtronic Equipment: MyCareLink Patient Monitor Vulnerabilities: Insufficient Verification of Data Authenticity, Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow an attacker with...

7.1CVSS6.6AI score0.00364EPSS
SaveExploits0References10
NVD
NVD
•added 2018/07/03 1:29 a.m.•24 views

CVE-2018-8868

Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit oth...

6.9CVSS6.6AI score0.00333EPSS
SaveExploits0References2
Prion
Prion
•added 2018/07/03 1:29 a.m.•28 views

Input validation

Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions, contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An...

6.9CVSS6.6AI score0.00333EPSS
SaveExploits0References1
Rows per page