Lucene search
+L

204 matches found

Prion
Prion
added 2020/09/11 1:15 p.m.15 views

Design/Logic Flaw

In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...

2.7CVSS4.9AI score0.00653EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/09/11 12:50 p.m.54 views

CVE-2020-16218 Philips Patient Monitoring Devices Cross-site Scripting

In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...

3.8AI score0.00653EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2020/09/11 12:00 a.m.7 views

PT-2020-14817 · Philips · Patient Information Center Ix

Name of the Vulnerable Software and Affected Versions: Patient Information Center iX PICiX versions B.02, C.02, C.03 Description: The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other...

3.5CVSS3.6AI score0.00653EPSS
SaveExploits0References4
ThreatPost
ThreatPost
added 2020/08/26 1:49 p.m.91 views

Medical Data Leaked on GitHub Due to Developer Errors

Developer error caused the leak of 150,000 to 200,000 patient health records stored in productivity apps from Microsoft and Google that were recently found on GitHub. Dutch researcher Jelle Ursem discovered nine separate files of highly sensitive personal health information PHI from apps such as...

7.1AI score
SaveExploits0References17
ICS
ICS
added 2020/08/20 12:00 a.m.58 views

Philips SureSigns VS4

1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION : Exploitable remotely Vendor : Philips Equipment : SureSigns VS4 Vulnerabilities : Improper Input Validation, Improper Access Control, Improper Authentication 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker...

6.3CVSS4.7AI score0.01003EPSS
SaveExploits0References5
OSV
OSV
added 2020/06/29 2:15 p.m.6 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS7.1AI score0.00483EPSS
SaveExploits0References2
OSV
OSV
added 2020/06/29 2:15 p.m.5 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS5.8AI score0.00496EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.5 views

Baxter PrismaFlex and PrismMax Information Disclosure Vulnerabilities

The Baxter PrismaFlex and PrismMax are both critical care devices from Baxter. An information disclosure vulnerability exists in Baxter PrismaFlex all versions and PrismMax prior to version 3.x. The vulnerability stems from the failure of an affected device to encrypt e.g., TLS/SSL transmitted da...

7.5CVSS6.2AI score0.00496EPSS
SaveExploits0References1
Malwarebytes
Malwarebytes
added 2019/11/13 1:00 p.m.55 views

Labs report finds cyberthreats against healthcare increasing while security circles the drain

The team at Malwarebytes Labs is at it again, this time with a special edition of our quarterly CTNT report—Cybercrime tactics and techniques: the 2019 state of healthcare. Over the last year, we gathered global data from our product telemetry, honeypots, threat intelligence, and research efforts...

0.5AI score
SaveExploits0
CNVD
CNVD
added 2019/09/05 12:00 a.m.6 views

BD Pyxis Authorization Issues Vulnerability

BD Pyxis is a medication management system from BD Medical BD. An authorization issue vulnerability exists in BD Pyxis ES versions 1.3.4 through 1.6.1 and Pyxis Enterprise Server Windows Server versions 4.4 through 4.12, which can be exploited by an attacker to gain access to a previous user's...

8.8CVSS6.8AI score0.01263EPSS
SaveExploits0References1
The Hacker News
The Hacker News
added 2019/08/30 9:37 a.m.3 views

Ransomware Hits Dental Data Backup Service Offering Ransomware Protection

THIS WEEK IN THE IRONIC NEWS: DDS Safe, an online cloud-based data backup system that hundreds of dental practice offices across the United States are using to safeguard medical records and other information of their patients from ransomware attacks has been hit with ransomware. Provided by two...

6.7AI score
SaveExploits0
Malwarebytes
Malwarebytes
added 2019/05/24 6:05 p.m.260 views

Medical industry struggles with PACS data leaks

In the medical world, sharing patient data between organizations and specialists has always been an issue. X-Rays, notes, CT scans, and any other data or related files have always existed and been shared in their physical forms slides, paperwork. When a patient needed to take results of a test to...

7AI score
SaveExploits0
Malwarebytes
Malwarebytes
added 2019/03/19 3:00 p.m.87 views

New research finds hospitals are easy targets for phishing attacks

New research from Brigham and Women’s Hospital in Boston finds hospital employees are extremely vulnerable to phishing attacks. The study highlights just how effective phishing remains as a tactic—the need for defense against and awareness of email scams is more critical than ever. The research w...

7AI score
SaveExploits0
ThreatPost
ThreatPost
added 2019/03/07 9:01 p.m.63 views

RSA Conference 2019: Ultrasound Hacked in Two Clicks

SAN FRANCISCO – Researchers have highlighted the endemic insecurity of the hospital environment by executing a proof-of-concept attack on an ultrasound machine. In doing so, they were able to gain access to the machine’s entire database of patient ultrasound images. Check Point Research worked wi...

SaveExploits0References5
HackRead
HackRead
added 2018/09/16 4:11 p.m.24 views

Medical records & patient-doctor recordings of thousands of people exposed

By Carolina Another day, another trove of medical records leaked online, thanks to a misconfigured AWS S3 bucket. Medical records are considered to be sensitive documents and when a malicious third party has access to them it is a bad news as these records can be used for fraud, blackmailing and...

0.5AI score
SaveExploits0
ICS
ICS
added 2018/05/22 12:00 a.m.152 views

BD Kiestra and InoquIA Systems (Update A)

1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION : Exploitable from adjacent network Vendor : Becton, Dickinson and Company BD Equipment : BD Kiestra and InoqulA systems Vulnerabilities : Product UI does not Warn User of Unsafe Actions 2. UPDATE INFORMATION This updated advisory is a follow-up to the...

6.3CVSS6.6AI score0.00437EPSS
SaveExploits0References5
ICS
ICS
added 2018/04/17 12:00 p.m.100 views

Biosense Webster Carto 3 System Vulnerabilities

1. EXECUTIVE SUMMARY Biosense Webster Inc. BWI, a Johnson & Johnson company, has produced a software update that applies operating system patches and anti-virus signature updates to close known vulnerabilities in the operating system of the CARTO 3 System, a 3D cardiovascular mapping platform...

6.7AI score
SaveExploits0References19
CNVD
CNVD
added 2018/03/21 12:00 a.m.6 views

DocuTrac QuicDoc and Office Therapy DTISQLInstaller.exe Information Disclosure Vulnerability

DocuTrac QuicDoc and Office Therapy are both products of DocuTrac, Inc.DocuTrac QuicDoc is a behavioral health management software for healthcare teams.Office Therapy is an office practice management system.DTISQLInstaller.exe is one of the DTISQLInstaller.exe is one of the executable programs. A...

10CVSS6.6AI score0.01641EPSS
SaveExploits1References1
OSV
OSV
added 2018/03/20 5:29 p.m.8 views

CVE-2018-5438

Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record EMR system, where ISCV is in KIOSK mo...

6.3CVSS5.8AI score0.00396EPSS
SaveExploits0References3
CNVD
CNVD
added 2017/11/16 12:00 a.m.13 views

Philips IntelliSpace Cardiovascular System and Xcelera System Plaintext Storage Vulnerability

The Philips IntelliSpace Cardiovascular and Xcelera systems predecessor to IntelliSpace Cardiovascular are comprehensive cardiac imaging and information management software. The Philips IntelliSpace Cardiovascular System and Xcelera System have a plaintext storage vulnerability where credentials...

7.2CVSS6.8AI score0.01586EPSS
SaveExploits0References1
Rows per page
Query Builder