CVE
CVE
•added 2025/07/24 3:26 a.m.•44 views

CVE-2025-4394

CVE-2025-4394 affects Medtronic MyCareLink Patient Monitor models 24950 and 24952. The root cause is an unencrypted filesystem on internal storage that allows a physical attacker with access to read and modify files. The CVSS 3.1 vector (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) yields a base score of...

6.8CVSS6AI score0.002EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2025/07/24 3:26 a.m.•43 views

CVE-2025-4394 Medtronic MyCareLink Patient Monitor Unencrypted Filesystem Vulnerability

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS0.002EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/07/24 12:00 a.m.•9 views

CVE-2025-4393: Deserialization of Untrusted Data

Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before Jun...

6.5CVSS5.8AI score0.0018EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/07/24 12:00 a.m.•16 views

PT-2025-30628 · Medtronic · Mycarelink Patient Monitor 24952 +1

Name of the Vulnerable Software and Affected Versions: Medtronic MyCareLink Patient Monitor models 24950 and 24952 before June 25, 2025 Description: The Medtronic MyCareLink Patient Monitor contains an internal service that deserializes data. A local attacker can interact with this service by...

6.5CVSS6.3AI score0.0018EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2025/07/24 12:00 a.m.•26 views

PT-2025-30629 · Medtronic · Mycarelink Patient Monitor

Name of the Vulnerable Software and Affected Versions: Medtronic MyCareLink Patient Monitor versions 24950 and 24952 before June 25, 2025 Description: The Medtronic MyCareLink Patient Monitor utilizes an unencrypted filesystem on its internal storage. This allows an attacker with physical access ...

6.8CVSS5.8AI score0.002EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2025/07/24 12:00 a.m.•16 views

PT-2025-30630 · Medtronic · Mycarelink Patient Monitor

Name of the Vulnerable Software and Affected Versions: Medtronic MyCareLink Patient Monitor models 24950 and 24952 before June 25, 2025 Description: The Medtronic MyCareLink Patient Monitor contains a built-in user account with no password. This allows an attacker with physical access to log in...

6.8CVSS6.5AI score0.00284EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/07/24 12:00 a.m.•11 views

CVE-2025-4395: Empty Password in Configuration File

Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS5.7AI score0.00284EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/07/24 12:00 a.m.•8 views

CVE-2025-4394: Cleartext Storage of Sensitive Information

Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025...

6.8CVSS5.8AI score0.002EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/05/23 11:41 a.m.•21 views

CVE-2025-0683

In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a...

8.2CVSS6.9AI score0.00792EPSS
SaveExploits0References1
CISA
CISA
•added 2025/02/25 12:00 p.m.•24 views

CISA Releases Two Industrial Control Systems Advisories

CISA released two Industrial Control Systems ICS advisories on February 25, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-056-01 Rockwell Automation PowerFlex 755 ICSMA-25-030-01 Contec Health CMS8000 Patien...

7AI score
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2025/02/25 12:00 a.m.•7 views

PT-2025-7902

Name of the Vulnerable Software and Affected Versions Contec Health - CMS8000 Patient Monitor affected versions not specified Description The issue concerns the "update" binary in the firmware of the affected product, which sends attempts to mount to a hard-coded, routable IP address, bypassing...

7.7CVSS0.00483EPSS
SaveExploits0References15
RedhatCVE
RedhatCVE
•added 2025/02/06 2:18 a.m.•17 views

CVE-2025-0626

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS7.7AI score0.01149EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/02/05 10:30 a.m.•21 views

CVE-2024-12248

Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...

9.8CVSS7.6AI score0.01299EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2025/02/04 12:00 a.m.•16 views

medical monitoring device buffer overflow

The vulnerability of the microprogrammed software of the CMS8000 Patient Monitor and Epsimed MN-120 medical devices related to the execution of operations outside the buffer in memory. Exploiting this vulnerability can allow an attacker, operating remotely, to gain unauthorized access to protecte...

10CVSS8.7AI score0.01299EPSS
SaveExploits0References6
CVE
CVE
•added 2025/01/30 6:17 p.m.•90 views

CVE-2025-0683

The CVE-2025-0683 entry affects Contec Health CMS8000 Patient Monitor. In its default configuration, it transmits plain-text patient data to a hard-coded public IP address, enabling potential data leakage to any device on that IP and enabling MITM-like interception. Public advisories (CISA ICS wa...

8.2CVSS6AI score0.00792EPSS
SaveIn wildExploits0References4
Vulnrichment
Vulnrichment
•added 2025/01/30 6:17 p.m.•9 views

CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS7.7AI score0.01149EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2025/01/30 6:17 p.m.•54 views

CVE-2025-0626 Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor

The "monitor" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to...

7.7CVSS0.01149EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2025/01/30 6:17 p.m.•60 views

CVE-2024-12248 Out-of-bounds Write vulnerability in Contec Health CMS8000 Patient Monitor

Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution...

9.8CVSS0.01299EPSS
SaveExploits0References2
CVE
CVE
•added 2025/01/30 6:17 p.m.•109 views

CVE-2024-12248

The CVE-2024-12248 issue affects Contec Health CMS8000 Patient Monitor. It is an out-of-bounds write vulnerability allowing an attacker to craft UDP requests to write arbitrary data, potentially enabling remote code execution. Connected documents confirm the affected product family (CMS8000 CMS a...

9.8CVSS9.8AI score0.01299EPSS
SaveIn wildExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/01/30 12:00 a.m.•7 views

CVE-2025-0683: Exposure of Private Personal Information to an Unauthorized Actor

In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text patient data to a hard-coded public IP address when a patient is hooked up to the monitor. This could lead to a leakage of confidential patient data to any device with that IP address or an attacker in a...

8.2CVSS8.1AI score0.00792EPSS
SaveExploits0References1