OpenEMR 安全漏洞
OpenEMR is an open source medical management system from the OpenEMR community. The system can be used for medical practice management, electronic medical records, prescription writing and medical billing requests. An access control error vulnerability exists in OpenEMR version 5.0.2.1, which ste...
COVID-19 and HIPAA Enforcement Discretion Leaves Healthcare Organizations Vulnerable to Ransomware Attacks
Patient engagement is a term that has been discussed in healthcare for years. But now, its an urgent priority as providers work to vaccinate millions of Americans. The COVID-19 pandemic has put increased pressure on healthcare providers to ramp up digital communications with patients regarding...
Code injection
PHPGURUKUL Hospital Management System V 4.0 does not properly restrict access to admin/dashboard.php, which allows attackers to access all data of users, doctors, patients, change admin password, get appointment history and access all session logs...
CVE-2020-35745
PHPGURUKUL Hospital Management System V 4.0 does not properly restrict access to admin/dashboard.php, which allows attackers to access all data of users, doctors, patients, change admin password, get appointment history and access all session logs...
Telemed Poll Uncovers Biggest Risks and Best Practices
Healthcare organizations have gone virtual during the COVID-19 pandemic, just like the rest of us – with the use of telehealth services becoming the go-to format for med checks, routine consultations and therapist visits. But how safe are these services when it comes to patient data? In an...
Insider Report: Healthcare Security Woes Balloon in COVID-Era
In 2020, the healthcare industry began a massive shift, as legacy cybersecurity issues merged with new security challenges spurred on by the spread of COVID-19. Even before the pandemic, the medical arena wrestled with major cybersecurity challenges, including insecure medical devices, protecting...
OpenClinic GA License Issues Vulnerability
OpenClinic GA is an open source hospital information management system. The system supports financial management, clinical management and laboratory management. An authorization issue vulnerability exists in OpenClinic version 0.8.2, which stems from being affected by a missing authentication...
Healthcare 2021: Cyberattacks to Center on COVID-19 Spying, Patient Data
Sophisticated cybercriminals have been trying to steal COVID-19 vaccine research – and researchers say there’s more of that to come going into 2021. Intellectual property theft will join ransomware, cloud-stored patient data theft and advanced phishing efforts as the main hallmarks of...
Ransomware Attacks Targeting Healthcare Surge: VMware Carbon Black experts Weigh in
Targeted, sophisticated, and costly – over the past month, several high-profile ransomware attacks have been reported with a specific focus on some of the largest healthcare providers across the world1. With the recent surge in telemedicine adoption due to the COVID-19 as well as the growth of...
COVID-19 Clinical Trials Slowed After Ransomware Attack
A ransomware attack has hit eResearchTechnology, a medical software company that supplies pharma companies with tools for conducting clinical trials – including trials for COVID-19 vaccines. The attackers could be financially motivated — or could be backed by a nation-state looking to gain...
CVE-2020-16218
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
CVE-2020-16218
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
Design/Logic Flaw
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
CVE-2020-16218 Philips Patient Monitoring Devices Cross-site Scripting
In Patient Information Center iX PICiX Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access t...
PT-2020-14817 · Philips · Patient Information Center Ix
Name of the Vulnerable Software and Affected Versions: Patient Information Center iX PICiX versions B.02, C.02, C.03 Description: The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other...
Medical Data Leaked on GitHub Due to Developer Errors
Developer error caused the leak of 150,000 to 200,000 patient health records stored in productivity apps from Microsoft and Google that were recently found on GitHub. Dutch researcher Jelle Ursem discovered nine separate files of highly sensitive personal health information PHI from apps such as...
Philips SureSigns VS4
1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION : Exploitable remotely Vendor : Philips Equipment : SureSigns VS4 Vulnerabilities : Improper Input Validation, Improper Access Control, Improper Authentication 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker...
CVE-2020-12037
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12036
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
Baxter PrismaFlex and PrismMax Information Disclosure Vulnerabilities
The Baxter PrismaFlex and PrismMax are both critical care devices from Baxter. An information disclosure vulnerability exists in Baxter PrismaFlex all versions and PrismMax prior to version 3.x. The vulnerability stems from the failure of an affected device to encrypt e.g., TLS/SSL transmitted da...