Lucene search
+L

2856 matches found

CVE
CVE
•added 2025/05/14 6:12 p.m.•75 views

CVE-2025-0136

CVE-2025-0136 affects PAN-OS on Intel-based Palo Alto Networks firewalls (PA-7500, PA-5400/5400f, PA-3400, PA-1600, PA-1400, PA-400). The issue arises from using AES-128-CCM for IPSec, which leads to unencrypted data transfer between devices connected to the PAN-OS firewall through IPSec. Affecte...

5.3CVSS6.7AI score0.00162EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/05/14 6:12 p.m.•49 views

CVE-2025-0136 PAN-OS: Unencrypted Data Transfer when using AES-128-CCM on Intel-based hardware devices

Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls PA-7500, PA-5400, PA-5400f, PA-3400, PA-1600, PA-1400, and PA-400 Series leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec. This issue does not affect Clou...

5.3CVSS0.00162EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/05/14 6:12 p.m.•33 views

CVE-2025-0136 PAN-OS: Unencrypted Data Transfer when using AES-128-CCM on Intel-based hardware devices

Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls PA-7500, PA-5400, PA-5400f, PA-3400, PA-1600, PA-1400, and PA-400 Series leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec. This issue does not affect Clou...

5.3CVSS7.3AI score0.00162EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/05/14 6:09 p.m.•38 views

CVE-2025-0137 PAN-OS: Improper Neutralization of Input in the Management Web Interface

An improper input neutralization vulnerability in the management web interface of the Palo Alto Networks PAN-OS® software enables a malicious authenticated read-write administrator to impersonate another legitimate authenticated PAN-OS administrator. The attacker must have network access to the...

4.8CVSS0.00403EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/05/14 6:09 p.m.•21 views

CVE-2025-0137 PAN-OS: Improper Neutralization of Input in the Management Web Interface

An improper input neutralization vulnerability in the management web interface of the Palo Alto Networks PAN-OS® software enables a malicious authenticated read-write administrator to impersonate another legitimate authenticated PAN-OS administrator. The attacker must have network access to the...

4.8CVSS6.7AI score0.00403EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/05/14 6:07 p.m.•43 views

CVE-2025-0133 PAN-OS: Reflected Cross-Site Scripting (XSS) Vulnerability in GlobalProtect Gateway and Portal

A reflected cross-site scripting XSS vulnerability in the GlobalProtect™ gateway and portal features of Palo Alto Networks PAN-OS® software enables execution of malicious JavaScript in the context of an authenticated Captive Portal user's browser when they click on a specially crafted link. The...

6.9CVSS0.44973EPSS
SaveExploits8References1
Cvelist
Cvelist
•added 2025/05/14 5:37 p.m.•52 views

CVE-2025-0130 PAN-OS: Firewall Denial-of-Service (DoS) in the Web-Proxy Feature via a Burst of Maliciously Crafted Packets

A missing exception check in Palo Alto Networks PAN-OS® software with the web proxy feature enabled allows an unauthenticated attacker to send a burst of maliciously crafted packets that causes the firewall to become unresponsive and eventually reboot. Repeated successful attempts to trigger this...

8.2CVSS0.00424EPSS
SaveExploits0References1
CVE
CVE
•added 2025/05/14 5:37 p.m.•85 views

CVE-2025-0130

PAN-OS CVE-2025-0130 describes a denial-of-service: a missing exception check in the web-proxy feature allows an unauthenticated attacker to send malicious packets that crash the firewall and reboot, with repeated attempts leading to maintenance mode. Affected product is Palo Alto Networks PAN-OS...

8.2CVSS5.8AI score0.00424EPSS
SaveExploits0References1Affected Software1
Palo Alto Networks
Palo Alto Networks
•added 2025/05/14 4:00 p.m.•12 views

PAN-OS: Unencrypted Data Transfer when using AES-128-CCM on Intel-based hardware devices

Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls PA-7500, PA-5400, PA-5400f, PA-3400, PA-1400, and PA-400 Series leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec. This issue does not affect Cloud NGFWs,...

5.3CVSS5.9AI score0.00162EPSS
SaveExploits0References1
Palo Alto Networks
Palo Alto Networks
•added 2025/05/14 4:00 p.m.•8 views

PAN-OS: Improper Neutralization of Input in the Management Web Interface

An improper input neutralization vulnerability in the management web interface of the Palo Alto Networks PAN-OS® software enables a malicious authenticated read-write administrator to impersonate another legitimate authenticated PAN-OS administrator. The attacker must have network access to the...

4.8CVSS5.5AI score0.00403EPSS
SaveExploits0References1
Palo Alto Networks
Palo Alto Networks
•added 2025/05/14 4:00 p.m.•11 views

Informational Bulletin: No Impact of the Marvin Attack on PAN-OS

The Palo Alto Networks Product Security Assurance team has evaluated the applicability of CVEs related to the Marvin attack on PAN-OS. While we did not determine that any of these CVEs have significant impact on our PAN-OS software, some were fixed anyway out of an abundance of caution. You can...

5.8AI score
SaveExploits0References1
Palo Alto Networks
Palo Alto Networks
•added 2025/05/14 4:00 p.m.•10 views

PAN-OS: Firewall Denial-of-Service (DoS) in the Web-Proxy Feature via a Burst of Maliciously Crafted Packets

A missing exception check in Palo Alto Networks PAN-OS® software with the web proxy feature enabled allows an unauthenticated attacker to send a burst of maliciously crafted packets that causes the firewall to become unresponsive and eventually reboot. Repeated successful attempts to trigger this...

8.2CVSS7.1AI score0.00424EPSS
SaveExploits0References1
Palo Alto Networks
Palo Alto Networks
•added 2025/05/14 4:00 p.m.•12 views

PAN-OS: Reflected Cross-Site Scripting (XSS) Vulnerability in GlobalProtect Gateway and Portal

A reflected cross-site scripting XSS vulnerability in the GlobalProtect™ gateway and portal features of Palo Alto Networks PAN-OS® software enables execution of malicious JavaScript in the context of an authenticated Captive Portal user's browser when they click on a specially crafted link. The...

6.9CVSS6.5AI score0.44973EPSS
SaveExploits8References1
Positive Technologies
Positive Technologies
•added 2025/05/14 12:00 a.m.•20 views

PT-2025-21199

Name of the Vulnerable Software and Affected Versions: Palo Alto Networks PAN-OS affected versions not specified Description: A missing exception check in the software with the web proxy feature enabled allows an unauthenticated attacker to send a burst of maliciously crafted packets, causing the...

8.2CVSS5.8AI score0.00424EPSS
SaveExploits0References11
Positive Technologies
Positive Technologies
•added 2025/05/14 12:00 a.m.•27 views

PT-2025-21213 · Palo Alto Networks · Pan-Os

Name of the Vulnerable Software and Affected Versions: PAN-OS affected versions not specified Description: An improper input neutralization issue in the management web interface of the Palo Alto Networks PAN-OS software allows a malicious authenticated read-write administrator to impersonate...

5.5CVSS5.9AI score0.00403EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2025/05/14 12:00 a.m.•19 views

PT-2025-21210

Name of the Vulnerable Software and Affected Versions Palo Alto Networks PAN-OS affected versions not specified Description A reflected cross-site scripting XSS issue exists in the GlobalProtect gateway and portal features. This flaw allows the execution of malicious JavaScript within the browser...

6.9CVSS6.5AI score0.44973EPSS
SaveExploits8References65
Tenable Nessus
Tenable Nessus
•added 2025/05/14 12:00 a.m.•13 views

Palo Alto Networks PAN-OS 11.1.x < 11.1.6-h1 / 11.1.x < 11.1.7-h2 / 11.2.x < 11.2.5 Vulnerability

The version of Palo Alto Networks PAN-OS running on the remote host is 11.1.x prior to 11.1.6-h1 / 11.1.7-h2 or 11.2.x prior to 11.2.5. It is, therefore, affected by a vulnerability. A missing exception check in Palo Alto Networks PAN-OS software with the web proxy feature enabled allows an...

8.2CVSS5.6AI score0.00424EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
•added 2025/05/14 12:00 a.m.•14 views

Palo Alto Networks PAN-OS 10.1.x < 10.1.14-h14 / 10.2.x < 10.2.13 / 11.1.x < 11.1.8 / 11.2.x < 11.2.5 Vulnerability

The version of Palo Alto Networks PAN-OS running on the remote host is 10.1.x prior to 10.1.14-h14, 10.2.x prior to 10.2.13, 11.1.x prior to 11.1.8, or 11.2.x prior to 11.2.5. It is, therefore, affected by a vulnerability. An improper input neutralization vulnerability in the management web...

4.8CVSS5.7AI score0.00403EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2025/05/14 12:00 a.m.•29 views

Palo Alto Networks PAN-OS 安全漏洞

Palo Alto Networks PAN-OS is an operating system developed by Palo Alto Networks, Inc. for its firewall appliances. A security vulnerability exists in Palo Alto Networks PAN-OS that stems from improper input neutralization could lead to administrator impersonation...

4.8CVSS6.5AI score0.00403EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/14 12:00 a.m.•5 views

CVE-2025-0136: Cleartext Transmission of Sensitive Information

Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls PA-7500, PA-5400, PA-5400f, PA-3400, PA-1600, PA-1400, and PA-400 Series leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec. This issue does not affect Clou...

5.3CVSS6AI score0.00162EPSS
SaveExploits0References1
Rows per page
Query Builder