Lucene search
+L

25049 matches found

OSV
OSV
added 2026/04/09 9:45 p.m.6 views

CVE-2026-5778 Integer underflow leads to out-of-bounds access in sniffer ChaCha decrypt path.

Integer underflow in wolfSSL packet sniffer = 5.9.0 allows an attacker to cause a program crash in the AEAD decryption path by injecting a TLS record shorter than the explicit IV plus authentication tag into traffic inspected by sslDecodePacket. The underflow wraps a 16-bit length to a large valu...

2.1CVSS6.1AI score
SaveExploits0References3
ATTACKERKB
ATTACKERKB
added 2026/04/09 9:45 p.m.8 views

CVE-2026-5778

Integer underflow in wolfSSL packet sniffer = 5.9.0 allows an attacker to cause a program crash in the AEAD decryption path by injecting a TLS record shorter than the explicit IV plus authentication tag into traffic inspected by sslDecodePacket. The underflow wraps a 16-bit length to a large valu...

2.1CVSS5.9AI score0.00225EPSS
SaveExploits0References2
AlpineLinux
AlpineLinux
added 2026/04/09 9:45 p.m.38 views

CVE-2026-5778

Integer underflow in wolfSSL packet sniffer = 5.9.0 allows an attacker to cause a program crash in the AEAD decryption path by injecting a TLS record shorter than the explicit IV plus authentication tag into traffic inspected by sslDecodePacket. The underflow wraps a 16-bit length to a large valu...

6.5CVSS5.4AI score0.00225EPSS
SaveExploits0
Cvelist
Cvelist
added 2026/04/09 9:45 p.m.33 views

CVE-2026-5778 Integer underflow leads to out-of-bounds access in sniffer ChaCha decrypt path.

Integer underflow in wolfSSL packet sniffer = 5.9.0 allows an attacker to cause a program crash in the AEAD decryption path by injecting a TLS record shorter than the explicit IV plus authentication tag into traffic inspected by sslDecodePacket. The underflow wraps a 16-bit length to a large valu...

2.1CVSS0.00225EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2026/04/09 9:38 p.m.33 views

CVE-2026-33790 Junos OS: SRX Series: In a NAT64 configuration, receipt of a specific, malformed ICMPv6 packet will cause the srxpfe process to crash and restart.

An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow daemon flowd of Juniper Networks Junos OS on SRX Series allows an attacker sending a specific, malformed ICMPv6 packet to cause the srxpfe process to crash and restart. Continued receipt and processing of these...

8.7CVSS0.00331EPSS
SaveExploits0References1
CVE
CVE
added 2026/04/09 9:38 p.m.37 views

CVE-2026-33790

Threat summary (CVE-2026-33790): Juniper Junos OS on SRX Series is affected by an improper check in the flowd component during NAT64 translation. Receipt of a specific, malformed ICMPv6 packet to the device may crash and restart the srxpfe process, leading to a sustained DoS. Affected software in...

8.7CVSS5.9AI score0.00331EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2026/04/09 9:35 p.m.48 views

CVE-2026-33778

CVE-2026-33778 affects Junos OS on SRX Series and MX Series. The vulnerability is in the IPsec library used by kmd/iked, where processing a specifically malformed first ISAKMP packet can cause the kmd/iked process to crash and restart. This results in a momentary inability to establish new securi...

8.7CVSS5.9AI score0.00338EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2026/04/09 9:35 p.m.28 views

CVE-2026-33778 Junos OS: SRX Series, MX Series: When a specifically malformed first ISAKMP packet is received kmd/iked crashes

An Improper Validation of Syntactic Correctness of Input vulnerability in the IPsec library used by kmd and iked of Juniper Networks Junos OS on SRX Series and MX Series allows an unauthenticated, network-based attacker to cause a complete Denial-of-Service DoS. If an affected device receives a...

8.7CVSS0.00338EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2026/04/09 9:35 p.m.4 views

CVE-2026-33778 Junos OS: SRX Series, MX Series: When a specifically malformed first ISAKMP packet is received kmd/iked crashes

An Improper Validation of Syntactic Correctness of Input vulnerability in the IPsec library used by kmd and iked of Juniper Networks Junos OS on SRX Series and MX Series allows an unauthenticated, network-based attacker to cause a complete Denial-of-Service DoS. If an affected device receives a...

8.7CVSS5.8AI score0.00338EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2026/04/09 9:35 p.m.4 views

CVE-2026-33778

An Improper Validation of Syntactic Correctness of Input vulnerability in the IPsec library used by kmd and iked of Juniper Networks Junos OS on SRX Series and MX Series allows an unauthenticated, network-based attacker to cause a complete Denial-of-Service DoS. If an affected device receives a...

8.7CVSS5.9AI score0.00338EPSS
SaveExploits0References2Affected Software1
EUVD
EUVD
added 2026/04/09 9:31 p.m.19 views

EUVD-2025-209395

An attacker could use data obtained by sniffing the network traffic to forge packets in order to make arbitrary requests to Contemporary Controls BASC 20T...

9.8CVSS6AI score0.00443EPSS
SaveExploits0References4
CVE
CVE
added 2026/04/09 9:31 p.m.20 views

CVE-2026-33797

CVE-2026-33797 affects Juniper Networks Junos OS and Junos OS Evolved. An unauthenticated, adjacent attacker can reset only an established BGP session by sending a specific genuine BGP packet, causing DoS on that session. Repeated packets sustain the DoS. Affected are Junos OS 25.2 before 25.2R2 ...

7.4CVSS5.3AI score0.00166EPSS
SaveExploits0References2Affected Software2
CVE
CVE
added 2026/04/09 9:30 p.m.48 views

CVE-2026-33775

CVE-2026-33775 describes a memory leak (Missing Release of Memory after Effective Lifetime) in Juniper Junos OS MX Series bbe-smgd that can be triggered by a mismatch between configured and received packet types. An adjacent, unauthenticated attacker may cause a DoS by exhausting heap memory, aft...

7.1CVSS5.8AI score0.00195EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2026/04/09 9:30 p.m.26 views

CVE-2026-33775 Junos OS: MX Series: Mismatch between configured and received packet types causes memory leak in bbe-smgd

A Missing Release of Memory after Effective Lifetime vulnerability in the BroadBand Edge subscriber management daemon bbe-smgd of Juniper Networks Junos OS on MX Series allows an adjacent, unauthenticated attacker to cause a Denial of Service DoS. If the authentication packet-type option is...

7.1CVSS0.00195EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2026/04/09 9:30 p.m.5 views

CVE-2026-33775 Junos OS: MX Series: Mismatch between configured and received packet types causes memory leak in bbe-smgd

A Missing Release of Memory after Effective Lifetime vulnerability in the BroadBand Edge subscriber management daemon bbe-smgd of Juniper Networks Junos OS on MX Series allows an adjacent, unauthenticated attacker to cause a Denial of Service DoS. If the authentication packet-type option is...

7.1CVSS5.8AI score0.00195EPSS
SaveExploits0References1
NVD
NVD
added 2026/04/09 8:16 p.m.15 views

CVE-2025-13926

An attacker could use data obtained by sniffing the network traffic to forge packets in order to make arbitrary requests to Contemporary Controls BASC 20T...

9.8CVSS0.00443EPSS
SaveExploits0References3
CVE
CVE
added 2026/04/09 8:04 p.m.26 views

CVE-2026-4436

CVE-2026-4436 affects GPL Odorizers GPL750 (odorizer devices). A low-privileged remote attacker can send Modbus packets to manipulate registers that feed the odorant injection logic, potentially causing over- or under-injection of odorant into a gas line. Several sources (NVD/NIST, Red Hat, ENISA...

8.6CVSS6AI score0.00448EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
added 2026/04/09 7:47 p.m.5 views

CVE-2025-13926 Contemporary Controls BASC 20T Reliance on Untrusted Inputs in a Security Decision

An attacker could use data obtained by sniffing the network traffic to forge packets in order to make arbitrary requests to Contemporary Controls BASC 20T...

9.8CVSS5.9AI score0.00443EPSS
SaveExploits0References3
ATTACKERKB
ATTACKERKB
added 2026/04/09 7:47 p.m.8 views

CVE-2025-13926

An attacker could use data obtained by sniffing the network traffic to forge packets in order to make arbitrary requests to Contemporary Controls BASC 20T...

9.8CVSS6AI score0.00443EPSS
SaveExploits0References4Affected Software1
CVE
CVE
added 2026/04/09 7:47 p.m.23 views

CVE-2025-13926

CVE-2025-13926 concerns the BASC 20T from Contemporary Controls. The connected records indicate an attacker could exploit data sniffed from the network to forge requests toward the BASC 20T, implying a security decision relies on inputs that may be untrusted. The available details note a network-...

9.8CVSS6AI score0.00443EPSS
SaveExploits0References3
Rows per page