23 matches found
EUVD-2019-16092
Malware in sbrugna...
CVE-2019-6529
An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 or Software Version 1.1.13166...
Kunbus PR100088 Modbus Input Validation Error Vulnerability
Kunbus PR100088 Modbus is an industrial Ethernet gateway device from Kunbus, Germany. An input validation error vulnerability exists in versions prior to Kunbus PR100088 Modbus Release R02. The vulnerability stems from the network system or product not properly validating input data. No details o...
CVE-2019-6529
An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 or Software Version 1.1.13166...
CVE-2019-6529
An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 or Software Version 1.1.13166...
Design/Logic Flaw
An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 or Software Version 1.1.13166...
CVE-2019-6529
An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 or Software Version 1.1.13166...
CVE-2019-6529
Kunbus PR100088 Modbus gateway devices are affected by CVE-2019-6529 due to improper input validation in an FTP service. A specially crafted FTP request could crash versions prior to Release R02 (Software Version 1.1.13166). The issue is confirmed across multiple feeds (NVD entry; Red Hat CVE pag...
CVE-2019-6531
An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 if the attacker is in an MITM position...
CVE-2019-6531
An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 if the attacker is in an MITM position...
Design/Logic Flaw
An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 if the attacker is in an MITM position...
CVE-2019-6531
Affected product: Kunbus PR100088 Modbus gateway (all versions prior to Release R02 / Software 1.1.13166). Issue: Information Exposure Through Query Strings in GET Request (CWE-598) allows an MITM attacker to retrieve passwords via an HTTP GET request. Impact: password exposure with high severity...
CVE-2019-6531
An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 if the attacker is in an MITM position...
CVE-2019-6549
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 through FTP...
CVE-2019-6549
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 through FTP...
CVE-2019-6549
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166 through FTP...
CVE-2019-6549
CVE-2019-6549 concerns the PR100088 Modbus gateway where plain-text credentials are stored in an XML file and can be retrieved via FTP on all versions prior to Release R02 (or Software Version 1.1.13166). The issue is categorized under Information Exposure Through Get/Internal File Storage, enabl...
Authentication flaw
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
CVE-2019-6533
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...
CVE-2019-6533
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 or Software Version 1.1.13166...