326 matches found
Phoenix Contact ILC PLCs Improper Authentication (CVE-2016-8371)
The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Phoenix Contact ILC PLCs Denial of Service (CVE-2021-33541)
Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of...
Researchers Uncover Major Security Vulnerabilities in Industrial MMS Protocol Libraries
Details have emerged about multiple security vulnerabilities in two implementations of the Manufacturing Message Specification MMS protocol that, if successfully exploited, could have severe impacts in industrial environments. "The vulnerabilities could allow an attacker to crash an industrial...
IDEC Products (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION : Low Attack Complexity Vendor : IDEC Corporation Equipment : IDEC PLCs Vulnerabilities : Cleartext Transmission of Sensitive Information, Generation of Predictable Identifiers 2. RISK EVALUATION Successful exploitation of these vulnerabilities...
CVE-2024-41927
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to PLC's serial communication port, user credentials may be obtained. As a result, the program of the PLC may be obtained, and the PLC may be manipulated...
CVE-2024-41927
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to PLC's serial communication port, user credentials may be obtained. As a result, the program of the PLC may be obtained, and the PLC may be manipulated...
CVE-2024-41927
Cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to PLC's serial communication port, user credentials may be obtained. As a result, the program of the PLC may be obtained, and the PLC may be manipulated...
CVE-2024-41927
The CVE-2024-41927 entry covers a cleartext transmission of sensitive information in multiple IDEC PLCs (CWE-319). Affected products include IDEC’s FC6A/FC6B MICROSmart modules (various firmware versions) and FT1A/FT1B lines, with specific version ceilings noted in vendor advisories. The root cau...
PT-2024-29639 · Idec · Idec Plcs
Name of the Vulnerable Software and Affected Versions: IDEC PLCs affected versions not specified Description: A cleartext transmission of sensitive information vulnerability exists in multiple IDEC PLCs. If an attacker sends a specific command to the PLC's serial communication port, user...
AutomationDirect P3-550E Programming Software Connection CurrDir heap-based buffer overflow vulnerability
Talos Vulnerability Report TALOS-2024-1937 AutomationDirect P3-550E Programming Software Connection CurrDir heap-based buffer overflow vulnerability May 28, 2024 CVE Number CVE-2024-24947,CVE-2024-24946 SUMMARY A heap-based buffer overflow vulnerability exists in the Programming Software Connecti...
CISA Releases One Industrial Control Systems Advisory
CISA released one Industrial Control Systems ICS advisory on May 23, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-144-01 AutomationDirect Productivity PLCs CISA encourages users and administrators to review...
AutomationDirect Productivity PLCs
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : AutomationDirect Equipment : Productivity PLCs Vulnerabilities : Buffer Access with Incorrect Length Value, Out-of-bounds Write, Stack-based Buffer Overflow, Improper Access Control, Active...
Unitronics Vision series PLCs 安全漏洞
Unitronics Vision series PLCs are a series of PLCs from Unitronics, Inc. A security vulnerability exists in Unitronics Vision series PLCs that originates from a vulnerability that allows an attacker to retrieve message mode passwords without authentication. Affected products and versions:...
CISA Releases Three Industrial Control Systems Advisories
CISA released three Industrial Control Systems ICS advisories on April 18, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-24-109-01 Unitronics Vision Series PLCs ICSA-21-287-03 Mitsubishi Electric MELSEC iQ-R...
Unitronics Vision Legacy series (Update A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : Unitronics Equipment : Vision Legacy series Vulnerability : Storing Passwords in a Recoverable Format 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker...
Vulnerability in some TP-Link routers could lead to factory reset
Cisco Talos Vulnerability Research team has disclosed 10 vulnerabilities over the past three weeks, including four in a line of TP-Link routers, one of which could allow an attacker to reset the devices settings back to the factory default. A popular open-source software for internet-of-things Io...
Unitronics VisiLogic < 9.9.00 Default Password
The version of Unitronics VisiLogic installed on the remote host is prior to 9.9.00. It is, therefore, affected by a vulnerability. - Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with networ...
The vulnerabilities of the microprogramming software for Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58*S, and M580 CPU Safety BMEH58*S, as well as the programming tools EcoStruxure Control Expert and EcoStruxure Process Expert, allow a attacker to execute a “man-in-the-middle” attack.
The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, and M580 CPU Safety BMEH58S, as well as the PLC programming software EcoStruxure Control Expert and EcoStruxure Process...
U.S. Sanctions 6 Iranian Officials for Critical Infrastructure Cyber Attacks
The U.S. Treasury Department's Office of Foreign Assets Control OFAC announced sanctions against six officials associated with the Iranian intelligence agency for attacking critical infrastructure entities in the U.S. and other countries. The officials include Hamid Reza Lashgarian, Mahdi...