Lucene search
+L

3061 matches found

CNVD
CNVD
added 2021/03/19 12:0 a.m.4 views

Buffer Overflow Vulnerability in NA400 PLC at Aptar Technology Co.

NA400 PLC is a high performance programmable controller from OPTOTECHNIK Co. A buffer overflow vulnerability exists in the NA400PLC from Aptar Technology Corporation, which can be exploited by an attacker to cause a system crash...

7.4AI score
SaveExploits0
Zero Day Initiative
Zero Day Initiative
added 2021/03/11 12:0 a.m.24 views

(0Day) Fatek Automation PLC WinProladder PWD File Parsing Integer Underflow Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fatek Automation PLC WinProladder. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within...

7.8CVSS5.6AI score
SaveExploits0
Prion
Prion
added 2021/02/26 4:15 p.m.15 views

Design/Logic Flaw

The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and...

5CVSS7.7AI score0.01416EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/02/26 3:10 p.m.36 views

CVE-2020-24686 AC500 V2 webserver denial of service vulnerability

The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and...

7.5CVSS7.7AI score0.01416EPSS
SaveExploits0References1
CVE
CVE
added 2021/02/26 3:10 p.m.62 views

CVE-2020-24686

CVE-2020-24686 affects ABB AC500 V2 with onboard Ethernet. The issue is a denial of service in the PLC’s web visualization component: when exploited, the component stops responding and genuine users lose remote visibility of PLC state. If a user logs in while the vulnerability is exploited, the P...

7.5CVSS7.7AI score0.01416EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2021/02/25 12:0 a.m.5 views

Memory Out-of-Bounds Access Vulnerability in GX Works2

GX Works2 is a PLC programming software. A memory out-of-bounds access vulnerability exists in GX Works2. An attacker could exploit this vulnerability to cause the program to crash...

6.9AI score
SaveExploits0
CNVD
CNVD
added 2021/02/25 12:0 a.m.4 views

Code Injection Vulnerability in GX Works2

GX Works2 is a PLC programming software. A code injection vulnerability exists in GX Works2. An attacker can exploit this vulnerability to gain server privileges...

7.7AI score
SaveExploits0
CNVD
CNVD
added 2021/02/25 12:0 a.m.6 views

Denial of Service Vulnerability in GX Works2 (CNVD-2021-16895)

GX Works2 is a PLC programming software. A memory out-of-bounds access vulnerability exists in GX Works2. An attacker could exploit this vulnerability to cause the program to crash...

6.9AI score
SaveExploits0
NVD
NVD
added 2021/02/09 4:15 a.m.23 views

CVE-2020-24685

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS0.01608EPSS
SaveExploits0References1
Prion
Prion
added 2021/02/09 4:15 a.m.30 views

Design/Logic Flaw

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

5CVSS8.2AI score0.01608EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2021/02/09 3:57 a.m.72 views

CVE-2020-24685

CVE-2020-24685 affects ABB AC500 V2 with onboard Ethernet versions 2.8.4 and earlier. An unauthenticated, specially crafted network packet can cause a denial-of-service by stopping the PLC; after stop, physical access is required to restart the application. Public documents describe the vulnerabi...

8.6CVSS8.4AI score0.01608EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2021/02/09 3:57 a.m.33 views

CVE-2020-24685 AC500 V2 unauthenticated crafter packet vulnerability

An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...

8.6CVSS8.3AI score0.01608EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/02/09 12:0 a.m.13 views

ABB Asea Brown Boveri Ltd ABB AC500 V2 Security Breach

ABB Asea Brown Boveri Ltd ABB AC500 V2 is a PLC from ABB Asea Brown Boveri Ltd, Sweden.Suitable for simple control tasks and complex automation solutions. ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions contain a security vulnerability that can be exploited by an...

8.6CVSS5.8AI score0.01608EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/01/14 12:0 a.m.5 views

SIMATIC S7-PLCSM suffers from a denial of service vulnerability (CNVD-2021-05558)

SIMATIC S7-PLCSM is a PLC simulation software developed by Siemens. SIMATIC S7-PLCSM has a denial of service vulnerability that can be exploited by attackers to cause a denial of service...

7AI score
SaveExploits0
CNVD
CNVD
added 2021/01/14 12:0 a.m.8 views

SIMATIC S7-PLCSM suffers from a Denial of Service Vulnerability

SIMATIC S7-PLCSM is a PLC simulation software developed by Siemens. SIMATIC S7-PLCSM has a denial of service vulnerability that can be exploited by attackers to cause a denial of service...

7AI score
SaveExploits0
Talos
Talos
added 2021/01/07 12:0 a.m.106 views

Rockwell Automation RSLinx classic ethernet/IP server denial-of-service vulnerability

Summary A denial-of-service vulnerability exists in the Ethernet/IP server functionality of Rockwell Automation RSLinx Classic 2.57.00.14 CPR 9 SR 3. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of malicious packets to trigger this...

7.5CVSS7.5AI score0.03416EPSS
SaveExploits1
Kitploit
Kitploit
added 2020/12/11 11:30 a.m.35 views

Carnivore - Tool For Assessing On-Premises Microsoft Servers Authentication Such As ADFS, Skype, Exchange, And RDWeb

Carnivore is an assessment tool for Skype for Business, Exchange, ADFS, and RDWeb servers as well as some O365 functionality. Carnivore includes some new post-authentication Skype for Business functionality. Released as open source by NCC Group Plc - https://www.nccgroup.com/ Developed by Chris...

7.3AI score
SaveExploits0References3
OSV
OSV
added 2020/12/10 3:15 a.m.7 views

CVE-2020-12516

Older firmware versions FW1 up to FW10 of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack...

7.5CVSS5.7AI score
SaveExploits0References2
NVD
NVD
added 2020/12/10 3:15 a.m.27 views

CVE-2020-12516

Older firmware versions FW1 up to FW10 of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack...

7.5CVSS7.4AI score0.01864EPSS
SaveExploits0References2
Prion
Prion
added 2020/12/10 3:15 a.m.20 views

Denial of service

Older firmware versions FW1 up to FW10 of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack...

5CVSS7.4AI score0.01864EPSS
SaveExploits0References2Affected Software10
Rows per page
Query Builder