Lucene search
+L

3368 matches found

Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•3 views

PT-2022-10176

Name of the Vulnerable Software and Affected Versions Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description The issue allows an attacker to connect to the PLC and read the project without authorization during the time it is unlocked by an authorized user, resulti...

9.8CVSS5.8AI score0.01113EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•8 views

CVE-2021-32982: Cleartext Transmission of Sensitive Information

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange...

7.5CVSS7.2AI score0.00651EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•7 views

CVE-2021-32986: Authentication Bypass Using an Alternate Path or Channel

After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without...

9.8CVSS8.2AI score0.01113EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•5 views

CVE-2021-32980: Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...

9.8CVSS8.2AI score0.01113EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•7 views

CVE-2021-32978: Plaintext Storage of a Password

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...

7.5CVSS7.2AI score0.0101EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•1 views

PT-2022-10172

Name of the Vulnerable Software and Affected Versions Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was...

7.5CVSS5.7AI score0.0101EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2022/04/04 12:00 a.m.•3 views

PT-2022-10173

Name of the Vulnerable Software and Affected Versions Automation Direct CLICK PLC CPU Modules versions prior to v3.00 Description The issue allows an attacker to connect to the PLC while an existing connection is already active, due to insufficient protection against additional software programmi...

9.8CVSS5.8AI score0.01113EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/04/04 12:00 a.m.•9 views

CVE-2021-32984: Authentication Bypass Using an Alternate Path or Channel

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...

9.8CVSS8.2AI score0.01113EPSS
SaveExploits0References3
The Hacker News
The Hacker News
•added 2022/04/01 12:31 p.m.•64 views

Critical Bugs in Rockwell PLC Could Allow Hackers to Implant Malicious Code

Two new security vulnerabilities have been disclosed in Rockwell Automation's programmable logic controllers PLCs and engineering workstation software that could be exploited by an attacker to inject malicious code on affected systems and stealthily modify automation processes. The flaws have the...

10CVSS1.6AI score0.05213EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2022/03/21 12:00 a.m.•82 views

Siemens SIMATIC Industrial Products Missing Release of Memory After Effective Lifetime (CVE-2021-37205)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...

7.5CVSS7.2AI score0.0164EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2022/03/21 12:00 a.m.•75 views

Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37185)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...

7.5CVSS7.2AI score0.0206EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2022/03/21 12:00 a.m.•76 views

Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37204)

A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...

7.5CVSS7.2AI score0.02181EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2022/03/16 12:00 a.m.•16 views

The vulnerability of the development environment “CX-Programmer,” which is part of the software suite “CX-One” designed for programming and configuring Omron PLCs, stems from the use of memory after it has been freed. This allows a malicious actor to execute arbitrary code.

The vulnerability of the development environment provided by CX-Programmer, which is part of the CX-One software suite designed for programming and configuring Omron PLCs, relates to the use of memory after it is freed. Exploiting this vulnerability can allow an attacker to execute arbitrary code...

7.8CVSS7.6AI score0.01077EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
•added 2022/03/16 12:00 a.m.•14 views

The vulnerability of the development environment “CX-Programmer,” which is part of the software suite “CX-One” designed for programming and configuring Omron PLCs, arises from reading data from within allowable buffer limits. This allows attackers to disclose sensitive information or execute arbitrary code.

The vulnerability of the development environment provided by CX-Programmer, which is part of the CX-One software suite designed for programming and configuring Omron PLCs, relates to the use of memory after it is freed. Exploiting this vulnerability can allow an attacker to disclose sensitive...

7.8CVSS7.2AI score0.01025EPSS
SaveExploits0References3Affected Software1
zdt
zdt
•added 2022/03/10 12:00 a.m.•415 views

Siemens S7-1200 - Unauthenticated Start / Stop Command Vulnerability

Exploit Title: Unauthenticated Siemens S7-1200 CPU Start/Stop Command Exploit Author: RoseSecurity Vendor Homepage: https://www.siemens.com/global/en.html Version: V4.5 and below Tested on: Siemens S7-1200 CPU: 1215C IP == PLC IP address Start Command curl -i -s -k -X $'POST' \ -H $'Host: ' -H...

0.5AI score
SaveExploits0
Positive Technologies
Positive Technologies
•added 2022/03/09 12:00 a.m.•2 views

PT-2022-37654

Уязвимость микропрограммного обеспечения программируемого логического контроллера SIMATIC S7-1200 связана с возможностью неаутентифицированного пользователя выполнять команды. Эксплуатация уязвимости может позволить нарушителю, действующему удалённо, выполнить команды запуска и остановки контролл...

6.8CVSS5.8AI score
SaveExploits0References2
ICS
ICS
•added 2022/03/04 12:00 a.m.•91 views

Trailer Power Line Communications (PLC) J2497

1. EXECUTIVE SUMMARY CVSS v3 9.3 ATTENTION: Exploitable remotely/low attack complexity Equipment: Power Line Communications PLC: J2497 a.k.a. PLC4TRUCKS Vulnerabilities: Missing Authentication for Critical Function, Improper Protection against Electromagnetic Fault Injection 2. RISK EVALUATION...

9.1CVSS9.8AI score0.01201EPSS
SaveExploits0References4
CNVD
CNVD
•added 2022/02/15 12:00 a.m.•82 views

Schneider Electric Multiple Product Information Breach Vulnerability

Schneider Electric Modicon Quantum is a large programmable logic controller PLC for process applications, high availability and safety solutions. Schneider Electric Modicon M340 is a medium-range PLC programmable logic controller for industrial processes and infrastructure. An information...

7.5CVSS0.4AI score0.00962EPSS
SaveExploits0References1
CNVD
CNVD
•added 2022/02/15 12:00 a.m.•70 views

Schneider Electric Multiple Product Input Validation Error Vulnerability

Schneider Electric Modicon Quantum and Schneider Electric Modicon M340 are both products of Schneider Electric, a French company. The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure. The vulnerability sends a specially...

7.5CVSS1.7AI score0.01037EPSS
SaveExploits0References1
Openbugbounty
Openbugbounty
•added 2022/02/14 12:04 a.m.•12 views

plc-em.ru Cross Site Scripting vulnerability OBB-2371248

Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...

6.2AI score
SaveExploits0
Rows per page
Query Builder