Lucene search
+L

3368 matches found

Packet Storm
Packet Storm
•added 2014/07/15 12:00 a.m.•67 views

Elipse E3 Scada PLC Denial Of Service

VSLA Security Advisory FIRE-SCADA-DOS-2013-001: Http DoS Requests Flooding Crash Device Vulnerabilities Elipse E3 Scada PLC. LEVEL: EXTREME In our tests authorized by the customer, we can stop the entire plant. Published: 10/29/2013 Version: 1.0 Vendor: Elipse...

7.5CVSS6.5AI score0.09023EPSS
SaveExploits8
seebug.org
seebug.org
•added 2014/07/01 12:00 a.m.•41 views

Tri-PLC Nano-10 r81 - Denial of Service

No description provided by source. Exploit Title: Tri-PLC Nano-10 DoS Date: 07/11/2013 Exploit Author: Sapling Vendor Homepage: www.tri-plc.com Version: Firmware Version r81 and prior CVE : CVE-2013-2784 ICSA: ICSA-13-189-02 / The vulnerability exists due to a flaw in the PLC's ability to handle ...

7.8CVSS6.5AI score0.04041EPSS
SaveExploits5
seebug.org
seebug.org
•added 2014/07/01 12:00 a.m.•30 views

Galil-RIO Modbus - Denial of Service

No description provided by source. Exploit Title: Galil RIO-47100 Date: 05-01-2013 Exploit Author: Sapling Vendor Homepage: www.galilmc.com Version: Rio Firmware Prior to 1.1d CVE : CVE-2013-0699 ICSA: ICSA-13-116-01 / There are many different ways to crash this PLC but most of them are centraliz...

7.1CVSS6.5AI score0.02793EPSS
SaveExploits6
Nmap
Nmap
•added 2014/06/18 2:53 a.m.•297 views

s7-info NSE Script

Enumerates Siemens S7 PLC Devices and collects their device information. This script is based off PLCScan that was developed by Positive Research and Scadastrangelove . This script is meant to provide the same functionality as PLCScan inside of Nmap. Some of the information that is collected by...

10CVSS7.9AI score0.99448EPSS
SaveExploits35
NVD
NVD
•added 2014/03/24 2:20 p.m.•24 views

CVE-2014-2250

The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...

8.3CVSS6.6AI score0.03144EPSS
SaveExploits1References3
NVD
NVD
•added 2014/03/24 2:20 p.m.•26 views

CVE-2014-2252

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...

6.1CVSS6.5AI score0.01242EPSS
SaveExploits1References3
NVD
NVD
•added 2014/03/24 2:20 p.m.•29 views

CVE-2014-2254

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...

7.8CVSS6.5AI score0.04731EPSS
SaveExploits1References3
NVD
NVD
•added 2014/03/24 2:20 p.m.•25 views

CVE-2014-2258

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...

7.8CVSS6.5AI score0.04731EPSS
SaveExploits1References3
Prion
Prion
•added 2014/03/24 2:20 p.m.•29 views

Code injection

The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...

8.3CVSS6.9AI score0.03144EPSS
SaveExploits1References3Affected Software1
Prion
Prion
•added 2014/03/24 2:20 p.m.•25 views

Design/Logic Flaw

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...

7.8CVSS6.8AI score0.04731EPSS
SaveExploits1References3Affected Software1
Prion
Prion
•added 2014/03/24 2:20 p.m.•25 views

Design/Logic Flaw

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257...

7.8CVSS6.8AI score0.03678EPSS
SaveExploits1References3Affected Software1
Prion
Prion
•added 2014/03/24 2:20 p.m.•30 views

Design/Logic Flaw

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...

7.8CVSS6.8AI score0.04731EPSS
SaveExploits1References3Affected Software1
Prion
Prion
•added 2014/03/24 2:20 p.m.•21 views

Design/Logic Flaw

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...

6.1CVSS6.8AI score0.01242EPSS
SaveExploits1References3Affected Software1
Cvelist
Cvelist
•added 2014/03/22 1:00 a.m.•42 views

CVE-2014-2252

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...

6.4AI score0.01242EPSS
SaveExploits1References3
Cvelist
Cvelist
•added 2014/03/22 1:00 a.m.•46 views

CVE-2014-2254

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...

6.5AI score0.04731EPSS
SaveExploits1References3
Cvelist
Cvelist
•added 2014/03/22 1:00 a.m.•38 views

CVE-2014-2258

Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...

6.5AI score0.04731EPSS
SaveExploits1References3
CVE
CVE
•added 2014/03/22 1:00 a.m.•87 views

CVE-2014-2250

CVE-2014-2250 concerns Siemens SIMATIC S7-1200 CPUs with firmware before 4.0, where the PRNG has insufficient entropy. This weaknesses can enable remote attackers to defeat cryptographic protections and hijack sessions via unspecified vectors. Public material ties this to the S7-1200 family and n...

8.3CVSS6.7AI score0.03144EPSS
SaveExploits1References3Affected Software6
CVE
CVE
•added 2014/03/22 1:00 a.m.•70 views

CVE-2014-2252

Summary (CVE-2014-2252) : Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0 are affected by a vulnerability that allows remote attackers to cause a denial of service (defect-mode transition) by sending crafted PROFINET packets. The issue is tied to improper handling that enables ...

6.1CVSS6.6AI score0.01242EPSS
SaveExploits1References3Affected Software6
CVE
CVE
•added 2014/03/22 1:00 a.m.•92 views

CVE-2014-2254

CVE-2014-2254 affects Siemens SIMATIC S7-1200 CPU PLCs with firmware prior to 4.0. The vulnerability allows remote DoS (defect-mode transition) by sending crafted HTTP packets to the device’s web server (Port 80/443). Root cause is related to improper handling within the device’s HTTP interface, ...

7.8CVSS6.6AI score0.04731EPSS
SaveExploits1References3Affected Software6
CVE
CVE
•added 2014/03/22 1:00 a.m.•96 views

CVE-2014-2256

CVE-2014-2256 affects Siemens SIMATIC S7-1200 CPU PLCs with firmware before 4.0. The vulnerability is due to improper input validation in the device’s handling of packets, enabling a remote attacker to trigger a defect-mode transition and cause a denial of service via crafted ISO-TSAP packets. De...

7.8CVSS6.6AI score0.03678EPSS
SaveExploits1References3Affected Software6