3065 matches found
CVE-2016-9159
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
CVE-2016-9159
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
CVE-2016-9159
The vulnerability CVE-2016-9159 affects Siemens SIMATIC S7-300/400 PLC families (including related ET200/SIPLUS variants) where an attacker with network access to port 102/TCP (ISO-TSAP) or via Profibus can obtain credentials if protection-level 2 is configured. The ICS-CISA advisory SSA-731239 d...
Phoenix Contact ILC PLC Authentication Vulnerabilities
OVERVIEW Matthias Niedermaier and Michael Kapfer of HSASec Hochschule Augsburg have identified authentication vulnerabilities in Phoenix Contact’s ILC inline controller PLCs. Phoenix Contact GmbH & Co. KG has produced a mitigation plan that includes an update and recommended security practices to...
Mitigations Available for PanelShock Vulnerabilities in Schneider HMIs
One week after addressing a critical vulnerability in its industrial controller management software, Schneider Electric is in the midst of handling two more serious flaws in a number of its Magelis HMI products. HMI is short for human machine interface, a graphical visualization of an industrial...
Major Security Vulnerability Found In Schneider Electric ICS Gear
Schneider Electric is grappling with a critical vulnerability found in its flagship industrial controller management software called Unity Pro that allows hackers to remotely execute code on industrial networks. The warning comes from Indegy, an industrial cybersecurity firm. Indegy discovered th...
FATEK Automation PLC WinProladder Stack-Based Buffer Overflow Vulnerability
OVERVIEW A researcher working with Trend Micro’s Zero Day Initiative ZDI has identified a stack-based buffer overflow vulnerability in FATEK Automation's PLC WinProladder application. Fatek Automation Fatek has not produced an update to mitigate this vulnerability. ZDI has coordinated with...
Tengen Controls Model T-920 PLC IP Segmentation Syntax Denial of Service Vulnerability
T920 is an all-in-one, industrial-grade, high-performance programmable controller from TengControl Technology. A denial of service vulnerability exists in the IP fragmentation syntax of the Tengen T-920 PLC. An attacker can test its fragmentation reorganization capability by sending a data frame...
Siemens S7-300 Series PLC CPU Firmware <= 3.2.11 DoS
Binary data 7225.pasl...
pcworx-info NSE Script
This NSE script will query and parse pcworx protocol to a remote PLC. The script will send a initial request packets and once a response is received, it validates that it was a proper response to the command that was sent, and then will parse out the data. PCWorx is a protocol and Program by...
CVE-2016-5645
Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32BXBA devices have a hardcoded SNMP community, which makes it easier for remote attackers to load arbitrary firmware updates by leveraging knowledge of this community...
Hardcoded credentials
Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32BXBA devices have a hardcoded SNMP community, which makes it easier for remote attackers to load arbitrary firmware updates by leveraging knowledge of this community...
CVE-2016-5645
The provided Connected documents confirm a concrete issue: Rockwell Automation MicroLogix 1400 PLCs (models 1766-L32BWA/AWA/BXB/WAA, 1766-L32BXBA etc.) expose an undocumented privileged SNMP community string (“wheel”) alongside standard public/private, granting read/write access. This enables rem...
boels.pl XSS vulnerability
Vulnerable URL: https://www.boels.pl/search?q=%22%3E%3Csvg%2Fonload%3Dconfirm%28%2Fopenbugbounty%2F%29%3E Details: Description| Value ---|--- Patched:| Yes, at 30.08.2016 Latest check for patch:| 30.08.2016 13:20 GMT Vulnerability type:| XSS Vulnerability status:| Publicly disclosed Alexa Rank|...
Phoenix Contact ILC PLC Authentication Vulnerabilities
OVERVIEW Matthias Niedermaier and Michael Kapfer of HSASec Hochschule Augsburg have identified authentication vulnerabilities in Phoenix Contact’s ILC inline controller PLCs. Phoenix Contact GmbH & Co. KG has produced a mitigation plan that includes an update and recommended security practices to...
PLC Blaster Worm Targets Industrial Control PLCs
LAS VEGAS – Security researchers at Black Hat USA described a proof-of-concept worm that targets weaknesses within automated industrial control systems used to manage critical infrastructure and manufacturing. The worm, according to OpenSource Security, has the capability to autonomously search f...
The vulnerability of the microprogramming software of Siemens Simatic S7-1200 programmable logic controllers allows a malicious actor to cause malfunctions during maintenance operations.
The software of the Siemens SIMATIC S7-1200 programmable logic controller contains a vulnerability. When this vulnerability is exploited, a special SNMP packet can be sent to trigger a “failure to service” condition for the device...
PLC路由器任意文件遍历下载
No description provided by source...
(0Day) WECON LeviStudio PLC Type Buffer Overflow Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of WECON LeviStudio. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists in the handling of...
Rockwell Automation MicroLogix 1400 SNMP Credentials Vulnerability
OVERVIEW Cisco Talos, Cisco Systems, Inc.'s security intelligence and research group reported to Rockwell Automation that an undocumented and privileged Simple Network Management Protocol SNMP community string exists in MicroLogix 1400 programmable logic controllers PLC. Rockwell Automation has...