Lucene search
+L

3060 matches found

CVE
CVE
added 2025/09/23 10:27 p.m.11 views

CVE-2025-57882

CVE-2025-57882 affects the Click Plus C2-03CPU-2 device with firmware 3.60. It describes an improper resource shutdown/release that allows an unauthenticated attacker to cause a denial-of-service by exhausting all sessions in the Remote PLC application. Public documents confirm the issue and deta...

8.2CVSS6.7AI score0.00309EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/09/23 10:27 p.m.1 views

CVE-2025-57882 AutomationDirect CLICK PLUS Improper Resource Shutdown or Release

An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions in the Remote PLC...

8.2CVSS6.7AI score0.00309EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2025/09/23 10:24 p.m.1 views

CVE-2025-55038 AutomationDirect CLICK PLUS Missing Authorization

An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulnerability to read and modify PLC variabl...

7.6CVSS6.4AI score0.00237EPSS
SaveExploits0References2
CVE
CVE
added 2025/09/23 10:24 p.m.12 views

CVE-2025-55038

CVE-2025-55038 affects AutomationDirect CLICK PLUS C2-03CPU2 firmware 3.60. Through the KOPR protocol used by the Remote PLC app, authenticated users with low-level permissions can read and modify PLC variables beyond their authorization. Documents substantiate an authorization bypass with impact...

7.6CVSS6.4AI score0.00237EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2025/09/23 10:24 p.m.12 views

CVE-2025-55038 AutomationDirect CLICK PLUS Missing Authorization

An authorization bypass vulnerability has been discovered in the Click Plus C2-03CPU2 device firmware version 3.60. Through the KOPR protocol utilized by the Remote PLC application, authenticated users with low-level access permissions can exploit this vulnerability to read and modify PLC variabl...

7.6CVSS0.00237EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2025/09/23 10:15 p.m.15 views

CVE-2025-55069 AutomationDirect CLICK PLUS Predictable Seed in Pseudo-Random Number Generator

A predictable seed in pseudo-random number generator vulnerability has been discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software implements a predictable seed for its pseudo-random number generator, which compromises the security of the...

8.7CVSS0.00287EPSS
SaveExploits0References2
NVD
NVD
added 2025/09/23 10:15 p.m.7 views

CVE-2025-58069

The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session...

6.9CVSS0.00244EPSS
SaveExploits0References2
CVE
CVE
added 2025/09/23 10:8 p.m.20 views

CVE-2025-59484

CVE-2025-59484 affects AutomationDirect CLICK PLUS firmware 3.60, where an insecure RSA implementation enables use of a broken cryptographic algorithm. Public sources (NVD/Red Hat CVEs, CVE list, PT Security, and CISA advisory) describe the issue and confirm the affected device (Click Plus PLC) a...

8.7CVSS6.6AI score0.00115EPSS
SaveExploits0References2
CVE
CVE
added 2025/09/23 10:4 p.m.19 views

CVE-2025-58069

The CVE pertains to AutomationDirect CLICK PLUS firmware 3.60, where a hard-coded AES key is used to protect the initial messages of a new KOPS session. Root cause: hard-coded cryptographic key stored in the firmware. Impact: potential exposure of the cryptographic key and associated initial comm...

6.9CVSS6.6AI score0.00244EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2025/09/23 12:0 a.m.22 views

PT-2025-39223

Name of the Vulnerable Software and Affected Versions Click Plus PLC version 3.60 Description A hard-coded cryptographic key is present in firmware version 3.60 of the Click Plus PLC. This key, an AES key, is used to protect the initial messages of a new KOPS session. Recommendations At the momen...

6.9CVSS6.4AI score0.00244EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2025/09/23 12:0 a.m.14 views

PT-2025-39222

Name of the Vulnerable Software and Affected Versions Click Plus PLC firmware version 3.60 Description A flaw exists in the pseudo-random number generator due to a predictable seed. This compromises the security of generated private keys. Recommendations Update to a newer firmware version that...

8.7CVSS6.4AI score0.00287EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2025/09/23 12:0 a.m.4 views

AutomationDirect CLICK PLUS 安全漏洞

The AutomationDirect CLICK PLUS is a small programmable logic controller from AutomationDirect, Inc. A security vulnerability exists in AutomationDirect CLICK PLUS version 3.60, which stems from improper authorization of the KOPR protocol, and could result in a low-privileged user overstepping...

7.6CVSS6.5AI score0.00237EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2025/09/23 12:0 a.m.9 views

PT-2025-39226

Name of the Vulnerable Software and Affected Versions Click Plus C2-03CPU2 version 3.60 Description An authorization bypass exists in the Click Plus C2-03CPU2 device firmware. An authenticated user with low-level access can exploit this issue through the KOPR protocol, used by the Remote PLC...

7.6CVSS6.2AI score0.00237EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2025/09/10 12:0 a.m.8 views

PT-2025-81: OS command injection in Fastwel PLC web server

The vulnerability was identified in Fastwel programmable controllers, versions 3.4.5.0 CPM810-03, 3.4.9.1 СPM723-01. The discovered vulnerability is related to a failure to neutralize special elements used in operating system commands. Exploitation of this vulnerability allows a remote attacker t...

9.4CVSS6.1AI score
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2025/09/10 12:0 a.m.10 views

PT-2025-82: Insecure OS сommand execution mechanism in Fastwel PLC web server

The vulnerability was identified in Fastwel programmable controllers, versions 3.4.5.0 CPM810-03, 3.4.9.1 СPM723-01. The discovered vulnerability allows a remote attacker to execute arbitrary operating system commands and escalate their privileges to superuser level by sending a POST request via ...

9.4CVSS6.1AI score
SaveExploits0References2
Gitee
Gitee
added 2025/07/27 3:55 a.m.155 views

isf

This is a Python-based exploitation framework called ISF Industrial Exploitation Framework that is similar to Metasploit. It is designed for industrial control system ICS exploitation and is used for testing and demonstrating vulnerabilities in ICS devices. The framework is based on the open-sour...

7AI score
SaveExploits0
NVD
NVD
added 2025/07/08 7:15 a.m.12 views

CVE-2025-41665

An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file...

6.5CVSS0.00308EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/07/08 7:3 a.m.5 views

CVE-2025-41665 Phoenix Contact: DoS of the PLC due to incorrect default permissions possible

An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file...

6.5CVSS7.2AI score0.00308EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/07/08 7:3 a.m.16 views

CVE-2025-41665 Phoenix Contact: DoS of the PLC due to incorrect default permissions possible

An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file...

6.5CVSS0.00308EPSS
SaveExploits0References1
CVE
CVE
added 2025/07/08 7:3 a.m.28 views

CVE-2025-41665

CVE-2025-41665 affects Phoenix Contact PLCs (e.g., AXC F 1152 and related controllers) due to incorrect default permissions on a configuration file. A low-privileged remote attacker can force the watchdog to reboot the PLC, causing a denial of service. The vulnerability is documented with a CVSS ...

6.5CVSS6.6AI score0.00308EPSS
SaveExploits0References1
Rows per page
Query Builder