63 matches found
CIRCUTOR SGE-PLC1000和CIRCUTOR SGE-PLC50 安全漏洞
The CIRCUTOR SGE-PLC1000 and CIRCUTOR SGE-PLC50 are both a network concentrator from CIRCUTOR Spain. A security vulnerability exists in the CIRCUTOR SGE-PLC1000 and CIRCUTOR SGE-PLC50 version v9.0.2, which stems from the AddEvent function not validating the length of the username input, which cou...
PT-2025-48668
Name of the Vulnerable Software and Affected Versions Circutor SGE-PLC1000/SGE-PLC50 version 0.9.2 Description A stack-based buffer overflow exists in the TACACSPLUS implementation of the software. This allows a remote attacker to corrupt memory and potentially gain control of the system. The iss...
CIRCUTOR SGE-PLC1000和CIRCUTOR SGE-PLC50 安全漏洞
The CIRCUTOR SGE-PLC1000 and CIRCUTOR SGE-PLC50 are both a network concentrator from CIRCUTOR Spain. A security vulnerability exists in the CIRCUTOR SGE-PLC1000 and CIRCUTOR SGE-PLC50 v9.0.2, which stems from the ShowMeterPasswords function not validating the length of the meter parameter, which...
PT-2025-48674
Name of the Vulnerable Software and Affected Versions Circutor SGE-PLC1000/SGE-PLC50 version 9.0.2 Description A stack-based buffer overflow exists in Circutor SGE-PLC1000/SGE-PLC50 version 9.0.2. The ShowMeterDatabase function copies user-controlled input into a fixed-size buffer using sprintf...
PT-2025-48678
Name of the Vulnerable Software and Affected Versions Circutor SGE-PLC1000/SGE-PLC50 version 9.0.2 Description A heap-based buffer overflow exists in the software due to insufficient input validation. The ShowSupervisorParameters function copies user-supplied data to a fixed-size buffer using...
CIRCUTOR SGE-PLC1000和CIRCUTOR SGE-PLC50 安全漏洞
The CIRCUTOR SGE-PLC1000 and CIRCUTOR SGE-PLC50 are both a network concentrator from CIRCUTOR Spain. A security vulnerability exists in the CIRCUTOR SGE-PLC1000 and CIRCUTOR SGE-PLC50 version v0.9.2, which stems from a stack buffer overflow in the readpacket function of the TACACSPLUS...
EUVD-2021-20516
Malware in sbrugna...
EUVD-2021-20515
Malware in sbrugna...
Circutor SGE-PLC1000 OS Command Injection Vulnerability
Circutor SGE-PLC1000 is a smart metering system device. The primary function is to manage utility power through CIRWATT meters or other meters with PRIME technology.An operating system command injection vulnerability exists in firmware version 0.9.2b of the Circutor SGE-PLC1000, which can be...
CVE-2021-33841
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges...
CVE-2021-33842
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located...
CVE-2021-33842
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located...
Authentication flaw
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located...
Code injection
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges...
CVE-2021-33841
CVE-2021-33841 applies to the Circutor SGE-PLC1000 device running firmware version 0.9.2b. The vulnerability is an OS command injection caused by the device’s firmware not handling some requests correctly, enabling a remote attacker to inject code into the operating system with maximum privileges...
CVE-2021-33841 Circutor SGE-PLC1000 OS command Injection
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges...
CVE-2021-33842 Circutor SGE-PLC1000 improper authentication
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located...
CVE-2021-33842
CVE-2021-33842 concerns Circutor SGE-PLC1000 firmware version 0.9.2b with an improper authentication vulnerability in the cookie parameter, allowing an attacker to perform operations as an authenticated user. Exploitation requires the attacker to be on the same network as the affected device. Aff...
Circutor SGE-PLC1000 操作系统命令注入漏洞
Circutor SGE-PLC1000 is a smart metering system device. The primary function is to manage utility power through CIRWATT meters or other meters with PRIME technology.An operating system command injection vulnerability exists in firmware version 0.9.2b of the Circutor SGE-PLC1000, which can be...
PT-2021-20344 · Circutor · Circutor Sge-Plc1000
Name of the Vulnerable Software and Affected Versions: Circutor SGE-PLC1000 version 0.9.2b Description: The issue allows an attacker to perform operations as an authenticated user due to an improper authentication vulnerability in the cookie parameter. To exploit this, the attacker must be within...