48 matches found
Denial of Service Vulnerability in Proficy Machine Edition (CNVD-2020-32607)
Proficy Machine Edition is a PLC programming software developed by Emerson Trading Shanghai Co., Ltd. for designing, debugging, programming, and maintaining GE RX 3i and GE RX7i series PLCs, which is widely used in industrial control fields such as electric power, machinery manufacturing, steel,...
Command Execution Vulnerability in WideField2
WideField2 is a PLC programming software developed by Yokogawa Electric Group. WideField2 suffers from a command execution vulnerability that can be exploited by an attacker to gain server privileges...
Logic Flaw Vulnerability in Widefield3
Widefield3, also known as Yokogawa PLC Programming Software, is a versatile PLC programming tool. Widefield3 suffers from a logic flaw vulnerability that can be exploited by an attacker to reconstruct the protection password of a program block or macro program...
Modbus Slave PLC 7 - '.msw' Buffer Overflow (PoC)
Exploit Title: Modbus Slave PLC 7 - '.msw' Buffer Overflow PoC Author: Kağan Çapar Discovery Date: 2018-10-27 Software Link: https://www.modbustools.com/download/ModbusSlaveSetup32Bit.exe Vendor Homepage : https://www.modbustools.com Tested Version: 7 Tested on OS: Windows XP SP3 ENG other versio...
Modbus Slave PLC 7 Buffer Overflow
Exploit Title: Modbus Slave PLC 7 - '.msw' Buffer Overflow PoC Author: Kagan Capar Discovery Date: 2018-10-27 Software Link: https://www.modbustools.com/download/ModbusSlaveSetup32Bit.exe Vendor Homepage : https://www.modbustools.com Tested Version: 7 Tested on OS: Windows XP SP3 ENG other versio...
The vulnerability of the web server of the software complex for programming with CoDeSys allows a perpetrator to trigger a service failure or execute arbitrary code.
The vulnerability of the web server of the CoDeSys PLC programming software is related to buffer overflow in the stack. Exploiting this vulnerability can allow a malicious actor to cause service failures or execute arbitrary code using a specially crafted request...
WAGO PFC 200 SERIES Multiple Vulnerabilities
Exploit for hardware platform in category local exploits VENDOR DESCRIPTION “The WAGO-I/O-SYSTEM is a flexible fieldbus-independent solution for decentralized automation tasks. With the relay, function and interface modules, as well as overvoltage protection, WAGO provides a suitable interface fo...
Schneider Electric SoMachine HVAC
CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Schneider Electric Equipment: SoMachine HVAC Vulnerabilities: Buffer Overflow, DLL Hijack AFFECTED PRODUCTS The following version of SoMachine HVAC, a PLC programming software, is affected: SoMachine HVAC Versions 2.1.0 and prior. IMPACT...