195 matches found
CVE-2023-24610
NOSH 4a5cfdb allows remote authenticated users to execute PHP arbitrary code via the "practice logo" upload feature. The client-side checks can be bypassed. This may allow attackers to steal Protected Health Information because the product is for health charting...
Cross site scripting
IMPatienT before 1.5.2 allows stored XSS via onmouseover in certain text fields within a PATCH /modifyonto request to the ontology builder. This may allow attackers to steal Protected Health Information...
CVE-2022-43557 BD BodyGuard™ Pumps – RS-232 Interface Vulnerability
The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 serial port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information ePHI, protected heal...
CVE-2022-40263
BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable...
CVE-2022-40263
BD Totalys MultiProcessor (versions 1.70 and earlier) is affected by a hard-coded credentials vulnerability. Exploitation would require local access (or physical access if networked) to the system, with low attack complexity and user interaction not needed. Successful exploitation could allow an ...
#StopRansomware: Daixin Team
Summary Actions to take today to mitigate cyber threats from ransomware: Install updates for operating systems, software, and firmware as soon as they are released. Require phishing-resistant MFA for as many services as possible. Train users to recognize and report phishing attempts. Note: This...
Healthcare site leaks personal health information via Google and Meta tracking pixels
Advocate Aurora Health has disclosed that by visiting its websites users may have shared personal information, and possibly protected health information PHI, with Google and Meta Facebook. Advocate Aurora Health is the 11th largest not-for-profit, integrated health system in the US and provides...
CVE-2022-26390
The Baxter Spectrum Wireless Battery Module WBM stores network credentials and PHI only applicable to Spectrum IQ pumps using auto programming in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive informatio...
Information disclosure
The Baxter Spectrum Wireless Battery Module WBM stores network credentials and PHI only applicable to Spectrum IQ pumps using auto programming in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive informatio...
CVE-2022-26390
CVE-2022-26390 affects Baxter SIGMA Spectrum/Spectrum/WBM: Wireless Battery Module versions (e.g., v16, v16D38, v17, v17D19, v20D29–v20D32, v22D19–v22D28) where network credentials and PHI stored in unencrypted form on the WBM. Exploitation requires physical access to a device that hasn’t had dat...
CVE-2022-26390 Unencrypted internal storage of security credentials
The Baxter Spectrum Wireless Battery Module WBM stores network credentials and PHI only applicable to Spectrum IQ pumps using auto programming in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive informatio...
CVE-2022-30277
BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and...
Session fixation
BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and...
CVE-2022-30277
BD Synapsys, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability (CWE-613) that could allow a threat actor to access, modify, or delete sensitive data (ePHI/PHI/PII). Exploitation is not remotely exploitable per available documents. CVSS v3 base score: 5.7 ...
CVE-2022-30277 BD Synapsys™ – Insufficient Session Expiration
BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and...
BD Synapsys
1. EXECUTIVE SUMMARY CVSS v3 5.7 ATTENTION: Low attack complexity Vendor: Becton, Dickinson and Company BD Equipment: Synapsys Vulnerability: Insufficient Session Expiration 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access, modify, or delete...
For Health Insurance Companies, Web Apps Can Be an Open Wound
At IntSights, a Rapid7 company, our goal is to ensure organizations everywhere understand the threats facing them in today's cyber landscape. With this in mind, we took a focused look at the insurance industry — a highly targeted vertical due to the amount of valuable data these organizations hol...
CVE-2022-22765
BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...
Hardcoded credentials
BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive information, including electronic protected health information ePHI, protected health information PHI and personally identifiable information...
CVE-2022-22765
BD Viper LT system (BD) is affected for all versions 2.0 and later due to use of hard-coded credentials (CWE-798). The ICS advisory icsma-22-062-02 documents that an attacker could access, modify, or delete ePHI, PHI, and PII. The 4.0+ Windows 10 hardening in newer releases raises attack complexi...