1426 matches found
CVE-2019-10918
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier All versions, SIMATIC PCS 7 V8.1 All versions V8.1 with WinCC V7.3 Upd 19, SIMATIC PCS 7 V8.2 All versions V8.2 SP1 with WinCC V7.4 SP1 Upd11, SIMATIC PCS 7 V9.0 All versions V9.0 SP2 with WinCC V7.4 SP1 Upd11, SIMATIC WinCC TI...
CVE-2019-10918
Siemens CVE-2019-10918 affects multiple SIMATIC/WinCC products (e.g., WinCC/TIA Portal v14 with SP1 Upd 9 and v15 with Upd 3; WinCC Runtime Professional v14/v15; PCS7 with WinCC updaters). Root cause is an exposed DCOM interface that could let an authenticated, network-reachable attacker execute ...
CVE-2019-10917
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier All versions, SIMATIC PCS 7 V8.1 All versions V8.1 with WinCC V7.3 Upd 19, SIMATIC PCS 7 V8.2 All versions V8.2 SP1 with WinCC V7.4 SP1 Upd11, SIMATIC PCS 7 V9.0 All versions V9.0 SP2 with WinCC V7.4 SP1 Upd11, SIMATIC WinCC TI...
CVE-2019-10917
CVE-2019-10917 is a local-denial-of-service vulnerability affecting Siemens SIMATIC PCS7/WinCC product families (e.g., WinCC (TIA Portal) v13–v15 and WinCC Runtime Professional; PCS7 v8.0–9.0 with WinCC variants). The issue arises when a local attacker loads a project file, triggering a DoS and c...
CVE-2019-10916
CVE-2019-10916 affects Siemens SIMATIC PCS7 and WinCC/TIA Portal products (multiple versions). The root cause is SQL Injection in the project file handling, allowing an attacker who can access the project file to run arbitrary commands with the local database server’s privileges, impacting confid...
Siemens SIMATIC WinCC and SIMATIC PCS 7
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC WinCC and SIMATIC PCS 7 Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an...
ICSA-19-134-02 Siemens SIMATIC WinCC and SIMATIC PCS 7
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC WinCC and SIMATIC PCS 7 Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an...
CVE-2019-11507
In Pulse Secure Pulse Connect Secure PCS 8.3.x before 8.3R7.1 and 9.0.x before 9.0R3, an XSS issue has been found on the Application Launcher page...
CVE-2019-11508
CVE-2019-11508 affects Pulse Connect Secure (PCS) / Pulse Policy Secure (PPS) via the Pulse Secure vulnerability set. According to the connected sources, this CVE is a post‑auth issue in which an authenticated end-user can upload a malicious file to write arbitrary files to the local system on th...
CVE-2019-11508
In Pulse Secure Pulse Connect Secure PCS before 8.1R15.1, 8.2 before 8.2R12.1, 8.3 before 8.3R7.1, and 9.0 before 9.0R3.4, an authenticated attacker via the admin web interface can exploit Directory Traversal to execute arbitrary code on the appliance...
CVE-2019-11510
In Pulse Secure Pulse Connect Secure PCS 8.2 before 8.2R12.1, 8.3 before 8.3R7.1, and 9.0 before 9.0R3.4, an unauthenticated remote attacker can send a specially crafted URI to perform an arbitrary file reading vulnerability...
CVE-2019-11510
CVE-2019-11510 affects Pulse Secure Pulse Connect Secure (PCS). An unauthenticated remote attacker can exploit a crafted URI to perform an arbitrary file read on PCS appliances. Impact is described as reading arbitrary files from the device, which can facilitate further intrusion steps. Affected ...
Privilege Escalation
The pcs packages provide a command-line configuration system for the Pacemaker and Corosync utilities. A command injection flaw was found in the pcsd web UI. An attacker able to trick a victim that was logged in to the pcsd web UI into visiting a specially crafted URL could use this flaw to execu...
Remote command injection through an endpoint security product
TL;DR? We discovered command injection in a popular endpoint security product, Heimdal Thor. By using the product, customers PCs were exposed to compromise. Irony++ Heimdal fixed the issue quickly and responded well, but it appears that the vulnerability had been present in 650,000 PCs for around...
CVE-2018-20807
CVE-2018-20807 affects Pulse Secure Pulse Connect Secure (PCS) via an XSS in welcome.cgi. Affected: PCS 8.1.x before 8.1R12, 8.2.x before 8.2R9, 8.3.x before 8.3R3. Root cause: improper sanitization of a URL parameter in the WEB app, enabling client-side script execution. Impact: client-side code...
CVE-2018-20807
An XSS issue has been found in welcome.cgi in Pulse Secure Pulse Connect Secure PCS 8.1.x before 8.1R12, 8.2.x before 8.2R9, and 8.3.x before 8.3R3 due to one of the URL parameters not being sanitized properly...
CVE-2018-20814
The CVE-2018-20814 issue is a cross-site scripting (XSS) vulnerability in Psaldownload.cgi affecting Pulse Connect Secure (PCS) 8.3R2 and earlier and Pulse Policy Secure (PPS) 5.4RX and earlier (not applicable to PCS 8.1RX or PPS 5.2RX). Root cause is insufficient validation of client data in the...
Siemens Automation License Manager Detection (Windows SMB Login)
SMB login-based detection of Siemens Automation License Manager. Copyright C 2019 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free...
Cross-site Request Forgery (CSRF)
pcs is vulnerable to cross-site request forgery CSRF attacks. The vulnerability exists in pcsd web UI in pcs before 0.9.149...
Privilege Escalations
pcs is vulnerable to privilege escalation attacks. The vulnerability exists through a race condition in pcsd in PCS 0.9.139 and earlier uses a global variable to validate usernames, which allows remote authenticated users to gain privileges by sending a command that is checked for security after...