Lucene search
+L

823 matches found

Vulnrichment
Vulnrichment
•added 2024/07/18 4:33 p.m.•33 views

CVE-2023-40704 Philips Vue PACS Use of Default Credentials

The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity...

6.8CVSS8.2AI score0.00338EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
•added 2024/07/18 4:29 p.m.•41 views

CVE-2023-40539

...

6.2AI score
SaveExploits0
Cvelist
Cvelist
•added 2024/07/18 4:29 p.m.•42 views

CVE-2023-40539

...

SaveExploits0
CVE
CVE
•added 2024/07/18 4:29 p.m.•59 views

CVE-2023-40539

The CVE entry CVE-2023-40539 is associated with Philips Vue PACS and is documented in connected sources as Weak Password Requirements (CWE-521). The Philips advisory lists this vulnerability among others affecting Vue PACS versions prior to 12.2.8.400 and highlights that weak password controls co...

5.2AI score
SaveExploits0
Vulnrichment
Vulnrichment
•added 2024/07/18 4:23 p.m.•17 views

CVE-2023-40223

...

8.8AI score
SaveExploits0
Cvelist
Cvelist
•added 2024/07/18 4:23 p.m.•38 views

CVE-2023-40223

...

SaveExploits0
CVE
CVE
•added 2024/07/18 4:23 p.m.•52 views

CVE-2023-40223

CVE-2023-40223 affects Philips Vue PACS. The vulnerability is categorized as Improper Privilege Management (CWE-269) in Vue PACS components, with affected product/version details indicating versions prior to 12.2.8.410 are impacted. The technical overview notes an unintended sphere of control due...

5.9AI score
SaveExploits0
Vulnrichment
Vulnrichment
•added 2024/07/18 4:19 p.m.•19 views

CVE-2023-40159

...

6.8AI score
SaveExploits0
Cvelist
Cvelist
•added 2024/07/18 4:19 p.m.•35 views

CVE-2023-40159

...

SaveExploits0
CVE
CVE
•added 2024/07/18 4:19 p.m.•51 views

CVE-2023-40159

CVE-2023-40159 entry is rejected by its CVE Numbering Authority and does not represent an active vulnerability.

7AI score
SaveExploits0
ICS
ICS
•added 2024/07/18 6:00 a.m.•86 views

Philips Vue PACS (Update A)

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Philips Equipment : Vue PACS Vulnerabilities : Out-of-bounds Write, Deserialization of Untrusted Data, Uncontrolled Resource Consumption, Improper Privilege Management, Use of Default...

9.8CVSS9.2AI score0.49727EPSS
SaveExploits2References10
Positive Technologies
Positive Technologies
•added 2024/07/18 12:00 a.m.•19 views

PT-2024-12895 · Philips · Philips Vue Pacs

Name of the Vulnerable Software and Affected Versions: Philips Vue PACS affected versions not specified Description: The issue is related to the lack of strong password requirements for users, which could facilitate the compromise of user accounts by attackers. Recommendations: At the moment, the...

4.4CVSS6.7AI score
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2024/07/18 12:00 a.m.•39 views

PT-2024-12910 · Philips · Philips Vue Pacs

Name of the Vulnerable Software and Affected Versions: Philips Vue PACS affected versions not specified Description: The issue concerns the use of default credentials for potentially critical functionality in Philips Vue PACS. There is no information provided about the estimated number of...

9.8CVSS6.8AI score0.00338EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2024/07/18 12:00 a.m.•16 views

PT-2024-12860 · Philips · Philips Vue Pacs

Name of the Vulnerable Software and Affected Versions: Philips Vue PACS affected versions not specified Description: A validated user not explicitly authorized to have access to certain sensitive information could access Philips Vue PACS on the same network to expose that information...

8.2CVSS6.4AI score
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/07/18 12:00 a.m.•5 views

CVE-2023-40704: Use of Default Credentials

The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity...

9.8CVSS5.8AI score0.00338EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2024/07/18 12:00 a.m.•23 views

PT-2024-12867 · Philips · Philips Vue Pacs

Name of the Vulnerable Software and Affected Versions: Philips Vue PACS affected versions not specified Description: The issue is related to improper assignment, modification, tracking, or checking of actor privileges, resulting in an unintended sphere of control for that actor. Recommendations: ...

4.4CVSS6.5AI score
SaveExploits0References7
CNVD
CNVD
•added 2024/06/04 12:00 a.m.•8 views

File Upload Vulnerability in PACS System of Infinera Software (Shanghai) Co.

Infinera is a company specializing in the development of medical imaging systems. A file upload vulnerability exists in the PACS system of Infida Software Shanghai Co. Ltd. that can be exploited by an attacker to gain server privileges...

7.3AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
•added 2024/05/27 12:00 a.m.•19 views

The vulnerability of the built-in server of the medical image and data management system Sante PACS Server PG allows a hacker to execute arbitrary codes.

The vulnerability in the embedded DICOM server of the medical image and data management system Sante PACS Server PG is related to the lack of measures taken to protect the SQL query structure when processing the NAME parameter of a patient record. Exploiting this vulnerability allows an attacker ...

10CVSS8.3AI score0.00965EPSS
SaveExploits0References4Affected Software1
attackerkb
attackerkb
•added 2024/05/22 8:15 p.m.•8 views

CVE-2023-51637

Sante PACS Server PG Patient Query SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sante PACS Server PG. Authentication is not required to exploit this vulnerability. The specific flaw exists with...

9.8CVSS6.4AI score0.00965EPSS
SaveExploits0References2Affected Software1
NVD
NVD
•added 2024/05/22 8:15 p.m.•41 views

CVE-2023-51637

Sante PACS Server PG Patient Query SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sante PACS Server PG. Authentication is not required to exploit this vulnerability. The specific flaw exists with...

9.8CVSS10AI score0.00965EPSS
SaveExploits0References1
Rows per page