10 matches found
CVE-2024-41794: Use of Hard-coded Credentials
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they ar...
CVE-2024-41796: Unverified Password Change
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack CVE-2024-41795 an unauthenticated attacker could be able...
CVE-2024-41790: Improper Neutralization of Special Elements used in an OS Command
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges...
Siemens SENTRON 7KT PAC1260 Data Manager 操作系统命令注入漏洞
Siemens SENTRON 7KT PAC1260 Data Manager is a device for power monitoring and energy management from Siemens Germany. The Siemens SENTRON 7KT PAC1260 Data Manager suffers from an OS command injection vulnerability that stems from not cleaning up the region parameter of a specific POST request,...
CVE-2024-41791: Missing Authentication for Critical Function
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices does not authenticate report creation requests. This could allow an unauthenticated remote attacker to read or clear the log files on the device, reset the device or set the...
CVE-2024-41793: Missing Authentication for Critical Function
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could allow an unauthenticated remote attacker to enable remote access to the device...
CVE-2024-41795: Cross-Site Request Forgery (CSRF)
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices is vulnerable to Cross-Site Request Forgery CSRF attacks. This could allow an unauthenticated attacker to change arbitrary device settings by tricking a legitimate device...
CVE-2024-41788: Improper Neutralization of Special Elements used in an OS Command
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges...
CVE-2024-41792: Improper Limitation of a Pathname to a Restricted Directory
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges...
CVE-2024-41789: Improper Neutralization of Special Elements used in an OS Command
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager All versions. The web interface of affected devices does not sanitize the language parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges...