Lucene search
+L

14863 matches found

RedhatCVE
RedhatCVE
•added 2026/01/07 9:09 a.m.•10 views

CVE-2024-2448

An OS command injection vulnerability has been identified in LoadMaster. An authenticated UI user with any permission settings may be able to inject commands into a UI component using a shell command resulting in OS command injection...

8.8CVSS7.5AI score0.55422EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/07 12:00 a.m.•3 views

CVE-2025-15471: Improper Neutralization of Special Elements used in an OS Command

A vulnerability was detected in TRENDnet TEW-713RE 1.02. The impacted element is an unknown function of the file /goformX/formFSrvX. The manipulation of the argument SZCMD results in os command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. The...

10CVSS8.1AI score0.13705EPSS
SaveExploits1References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/07 12:00 a.m.•4 views

CVE-2025-15472: Improper Neutralization of Special Elements used in an OS Command

A flaw has been found in TRENDnet TEW-811DRU 1.0.2.0. This affects the function setDeviceURL of the file uapply.cgi of the component httpd . This manipulation of the argument DeviceURL causes os command injection. The attack can be initiated remotely. The exploit has been published and may be...

8.6CVSS7AI score0.2235EPSS
SaveExploits1References6
CNNVD
CNNVD
•added 2026/01/06 12:00 a.m.•27 views

Cayin Signage Media Player 操作系统命令注入漏洞

Cayin Signage Media Player is a series of electronic signage playback terminals from Cayin, a Taiwan-based company. An operating system command injection vulnerability exists in Cayin Signage Media Player version 3.0, which originates from an authenticated remote command injection vulnerability i...

8.8CVSS7.8AI score0.01433EPSS
SaveExploits1References7
NVD
NVD
•added 2026/01/05 10:15 a.m.•26 views

CVE-2025-5965

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Centreon Infra Monitoring Backup configuration in the administration setup...

7.2CVSS0.28229EPSS
SaveExploits0References2
OSV
OSV
•added 2026/01/05 10:06 a.m.•17 views

CVE-2025-5965 RCE via the backup feature available only to user with high privilege

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Centreon Infra Monitoring Backup configuration in the administration setup...

7.2CVSS6.8AI score
SaveExploits0References4
CVE
CVE
•added 2026/01/05 10:06 a.m.•43 views

CVE-2025-5965

Centreon Infra Monitoring is affected by an OS Command Injection in the backup configuration when a high-privilege user appends custom instructions. The root cause is improper neutralization of special elements used in OS commands. Affected versions include Infra Monitoring 25.10.0–25.10.1 (befor...

7.2CVSS5.9AI score0.28229EPSS
SaveExploits0References2Affected Software1
Vulnrichment
Vulnrichment
•added 2026/01/05 10:06 a.m.•17 views

CVE-2025-5965 RCE via the backup feature available only to user with high privilege

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Centreon Infra Monitoring Backup configuration in the administration setup...

7.2CVSS5.9AI score0.28229EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2026/01/05 10:06 a.m.•466 views

CVE-2025-5965 RCE via the backup feature available only to user with high privilege

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Centreon Infra Monitoring Backup configuration in the administration setup...

7.2CVSS0.28229EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/05 12:00 a.m.•3 views

CVE-2025-5965: Improper Neutralization of Special Elements used in an OS Command

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Centreon Infra Monitoring Backup configuration in the administration setup...

7.2CVSS5.9AI score0.28229EPSS
SaveExploits0References3
RedhatCVE
RedhatCVE
•added 2026/01/03 10:04 p.m.•33 views

CVE-2025-64120

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: from 2.3.8 before 2.5.1...

9.4CVSS7AI score0.0101EPSS
SaveExploits0References1
OSV
OSV
•added 2026/01/03 1:15 a.m.•15 views

CVE-2025-64124

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: before 2.5.1...

8.8CVSS7.7AI score0.0101EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/01/03 12:28 a.m.•57 views

CVE-2025-64124 Nuvation Energy Multi-Stack Controller OS Command Injection

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: before 2.5.1...

8.7CVSS0.0101EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/01/03 12:28 a.m.•9 views

CVE-2025-64124 Nuvation Energy Multi-Stack Controller OS Command Injection

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: before 2.5.1...

8.7CVSS5.8AI score0.0101EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/03 12:00 a.m.•2 views

CVE-2025-64124: Improper Neutralization of Special Elements used in an OS Command

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: before 2.5.1...

8.8CVSS5.8AI score0.0101EPSS
SaveExploits0References3
OSV
OSV
•added 2026/01/02 10:15 p.m.•14 views

CVE-2025-64120

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: from 2.3.8 before 2.5.1...

8.8CVSS8AI score0.0101EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/02 10:15 p.m.•23 views

CVE-2025-64120

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: from 2.3.8 before 2.5.1...

9.4CVSS0.0101EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/01/02 9:33 p.m.•10 views

CVE-2025-64120 Nuvation Energy Multi-Stack Controller OS Command Injection

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: from 2.3.8 before 2.5.1...

9.4CVSS8AI score0.0101EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/01/02 9:33 p.m.•48 views

CVE-2025-64120 Nuvation Energy Multi-Stack Controller OS Command Injection

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: from 2.3.8 before 2.5.1...

9.4CVSS0.0101EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/02 12:00 a.m.•2 views

CVE-2025-64120: Improper Neutralization of Special Elements used in an OS Command

Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability in Nuvation Energy Multi-Stack Controller MSC allows OS Command Injection.This issue affects Multi-Stack Controller MSC: from 2.3.8 before 2.5.1...

9.4CVSS8.2AI score0.0101EPSS
SaveExploits0References3
Rows per page
Query Builder