13225 matches found
CVE-2026-3517: Improper Neutralization of Special Elements used in a Command
OS Command Injection Remote Code Execution Vulnerability in API in Progress ADC Products allows an authenticated attacker with “Geo Administration” permissions to execute arbitrary commands on the LoadMaster appliance by exploiting unsanitized input in the 'addcountry' command...
CVE-2026-24506: Improper Neutralization of Special Elements used in an OS Command
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2025 release version 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an OS command injection vulnerability. A high privileged attacker with remote access could potentially exploit this...
CVE-2026-23774: Improper Neutralization of Special Elements used in an OS Command
Dell PowerProtect Data Domain with Data Domain Operating System DD OS of Feature Release versions 7.7.1.0 through 8.5, LTS2025 release version 8.3.1.0 through 8.3.1.10, LTS2024 release versions 7.13.1.0 through 7.13.1.40, contain an OS command injection vulnerability. A high privileged attacker...
Dell PowerProtect Data Domain OS Command Injection Vulnerability
Dell PowerProtect Data Domain is a data protection and deduplication storage appliance. An operating system command injection vulnerability exists in Dell PowerProtect Data Domain. The vulnerability stems from a failure to properly neutralize a specific element used for OS command injection, whic...
CVE-2026-26943: Improper Neutralization of Special Elements used in an OS Command
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2025 release version 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an OS command injection vulnerability. A high privileged attacker with remote access could potentially exploit this...
CVE-2026-32311: Improper Neutralization of Special Elements used in an OS Command
Flowsint is an open-source OSINT graph exploration tool designed for cybersecurity investigation, transparency, and verification. Flowsint allows a user to create investigations, which are used to manage sketches and analyses. Sketches have controllable graphs, which are comprised of nodes and...
CVE-2026-35582
Emissary is a P2P based data-driven workflow engine. In versions 8.42.0 and below, Executrix.getCommand is vulnerable to OS command injection because it interpolates temporary file paths into a /bin/sh -c shell command string without any escaping or input validation. The INFILEENDING and...
CVE-2026-35582 Emissary has an OS Command Injection via Unvalidated IN_FILE_ENDING / OUT_FILE_ENDING in Executrix
Emissary is a P2P based data-driven workflow engine. In versions 8.42.0 and below, Executrix.getCommand is vulnerable to OS command injection because it interpolates temporary file paths into a /bin/sh -c shell command string without any escaping or input validation. The INFILEENDING and...
CVE-2026-35582 Emissary has an OS Command Injection via Unvalidated IN_FILE_ENDING / OUT_FILE_ENDING in Executrix
Emissary is a P2P based data-driven workflow engine. In versions 8.42.0 and below, Executrix.getCommand is vulnerable to OS command injection because it interpolates temporary file paths into a /bin/sh -c shell command string without any escaping or input validation. The INFILEENDING and...
CVE-2026-35582: Improper Neutralization of Special Elements used in an OS Command
Emissary is a P2P based data-driven workflow engine. In versions 8.42.0 and below, Executrix.getCommand is vulnerable to OS command injection because it interpolates temporary file paths into a /bin/sh -c shell command string without any escaping or input validation. The INFILEENDING and...
EUVD-2026-23407
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS Command Injection vulnerability. A high privileged attacker...
CVE-2026-35072
Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command 'OS command...
CVE-2026-35072
Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command 'OS command...
CVE-2026-6483 Wavlink WL-WN530H4 internet.cgi snprintf os command injection
A vulnerability was found in Wavlink WL-WN530H4 20220721. This vulnerability affects the function strcat/snprintf of the file /cgi-bin/internet.cgi. The manipulation results in os command injection. It is possible to launch the attack remotely. The exploit has been made public and could be used...
CVE-2026-35073: Improper Neutralization of Special Elements used in an OS Command
Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command injection...
CVE-2026-6483: Improper Neutralization of Special Elements used in an OS Command
A vulnerability was found in Wavlink WL-WN530H4 20220721. This vulnerability affects the function strcat/snprintf of the file /cgi-bin/internet.cgi. The manipulation results in os command injection. It is possible to launch the attack remotely. The exploit has been made public and could be used...
CVE-2026-35072: Improper Neutralization of Special Elements used in an OS Command
Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command 'OS command...
WAVLINK WL-WN530H4 安全漏洞
The WAVLINK WL-WN530H4 is a high-performance USB wireless network card from the WAVLINK company. It supports 802.11ac dual-band Wi-Fi. The Wavlink WL-WN530H4 version 20220721 has a security vulnerability. This vulnerability stems from the use of os command injection in the function strcat/snprint...
PT-2026-33436
Name of the Vulnerable Software and Affected Versions Dell PowerProtect Data Domain versions 7.7.1.0 through 8.7.0.0 Dell PowerProtect Data Domain versions 8.3.1.0 through 8.3.1.20 Dell PowerProtect Data Domain versions 7.13.1.0 through 7.13.1.60 Description Improper neutralization of special...
CVE-2026-23500: Improper Neutralization of Special Elements used in an OS Command
Dolibarr is an enterprise resource planning ERP and customer relationship management CRM software package. In versions prior to 23.0.0 , the ODT to PDF conversion process in odf.php concatenates the MAINODTASPDF configuration constant directly into a shell command passed to exec without...