CVE-2022-41666

A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal ExpertV3.3 Hotfix 1 or prior, Pro-face...

7CVSS7.8AI score0.00141EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2022/11/04 12:00 a.m.•18 views

Schneider Electric EcoStruxure Operator Terminal Expert 数据伪造问题漏洞

Schneider Electric EcoStruxure Operator Terminal Expert is a touch screen configuration software from Schneider Electric, France. This software support is mainly used for creating and editing touch applications. A data forgery vulnerability exists in Schneider Electric EcoStruxure Operator Termin...

7.8CVSS7.6AI score0.00116EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2022/10/11 12:00 a.m.•21 views

PT-2022-6534 · Schneider Electric · Ecostruxure Operator Terminal Expert +1

Name of the Vulnerable Software and Affected Versions: EcoStruxure Operator Terminal Expert versions 3.3 Hotfix 1 or prior Pro-face BLUE versions 3.3 Hotfix 1 or prior Description: A vulnerability exists that allows adversaries with local user privileges to load a malicious DLL, which could lead ...

7.8CVSS7.4AI score0.00141EPSS
SaveExploits0References6
ICS
ICS
•added 2021/12/02 12:00 a.m.•57 views

Schneider Electric SESU

1. EXECUTIVE SUMMARY CVSS v3 3.8 ATTENTION: Low attack complexity Vendor: Schneider Electric Equipment: Schneider Electric Software Update SESU Vulnerability: Insufficient Entropy 2. RISK EVALUATION Successful exploitation of this vulnerability could cause unintended connection from an internal...

3.8CVSS4.8AI score0.00237EPSS
SaveExploits0References4
NVD
NVD
•added 2021/01/26 6:15 p.m.•28 views

CVE-2020-28221

A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE version details in the notification that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI...

9.8CVSS9.7AI score0.0205EPSS
SaveExploits0References1
CVE
CVE
•added 2021/01/25 5:08 p.m.•77 views

CVE-2020-28221

CVE-2020-28221 is an improper input validation (CWE-20) vulnerability in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE. The issue could allow arbitrary code execution when the Ethernet Download feature is enabled on the HMI. The provided sources identify the affected products but do not...

9.8CVSS9.5AI score0.0205EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/01/25 12:00 a.m.•7 views

CVE-2020-28221: Improper Input Validation

A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE version details in the notification that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI...

9.8CVSS6.3AI score0.0205EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2021/01/12 12:00 a.m.•3 views

PT-2021-3891

Name of the Vulnerable Software and Affected Versions EcoStruxure Operator Terminal Expert affected versions not specified Pro-face BLUE affected versions not specified Description The issue is related to insufficient input validation in the Ethernet Download feature of the affected software, whi...

10CVSS0.0205EPSS
SaveExploits0References7
Prion
Prion
•added 2020/11/19 10:15 p.m.•24 views

Privilege escalation

A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime Vijeo XD that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert...

7.2CVSS7.7AI score0.00313EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2020/11/19 9:05 p.m.•88 views

CVE-2020-7544

CVE-2020-7544 affects Schneider Electric EcoStruxure Operator Terminal Expert runtime (Vijeo XD). A CWE-269 improper privilege management vulnerability could enable privilege escalation on a workstation when interacting with a driver installed by the runtime. The vulnerability is reported for Eco...

7.8CVSS7.7AI score0.00313EPSS
SaveExploits0References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/11/19 12:00 a.m.•6 views

CVE-2020-7544: Improper Privilege Management

A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime Vijeo XD that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert...

7.8CVSS5.8AI score0.00313EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2020/11/19 12:00 a.m.•24 views

Schneider Electric EcoStruxure Operator Terminal Expert Permission License and Access Control Issues Vulnerability

Schneider Electric EcoStruxure Operator Terminal Expert is a touch screen configuration software from Schneider Electric, France. This software branch is primarily used to create and edit touch applications. EcoStruxure Operator Terminal Expert suffers from a privilege license and access control...

7.8CVSS7.1AI score0.00313EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2020/11/19 12:00 a.m.•4 views

PT-2020-19622

Name of the Vulnerable Software and Affected Versions EcoStruxure Operator Terminal Expert runtime Vijeo XD affected versions not specified Description A CWE-269 Improper Privilege Management issue exists that could cause privilege escalation on the workstation when interacting directly with a...

7.8CVSS0.00313EPSS
SaveExploits0References6
BDU FSTEC
BDU FSTEC
•added 2020/06/17 12:00 a.m.•17 views

The vulnerability of the software for configuring Schneider Electric EcoStruxure Operator Terminal Expert, related to incorrect processing of VXDZ files, allows a perpetrator to execute arbitrary code.

The vulnerability of Schneider Electric EcoStruxure Operator Terminal Expert software for configuring touchscreen displays is related to improper handling of VXDZ files. Exploiting this vulnerability can allow an attacker to execute arbitrary code using a specially crafted file or website...

7.8CVSS7.7AI score0.01136EPSS
SaveExploits0References4
OSV
OSV
•added 2020/06/16 8:15 p.m.•15 views

CVE-2020-7494

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior formerly known as Vijeo XD which could cause malicious code execution when opening the project file...

7.8CVSS7.5AI score0.01347EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/16 8:15 p.m.•39 views

CVE-2020-7493

A CWE-89: Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior formerly known as Vijeo XD which could cause malicious code execution when opening the project file...

7.8CVSS0.01136EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/16 8:15 p.m.•41 views

CVE-2020-7495

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior formerly known as Vijeo XD which could cause unauthorized write access outside of expected pa...

5.5CVSS0.00883EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/16 8:15 p.m.•34 views

CVE-2020-7497

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior formerly known as Vijeo XDwhich could cause arbitrary application execution when the computer starts...

9.8CVSS0.02289EPSS
SaveExploits0References1
NVD
NVD
•added 2020/06/16 8:15 p.m.•42 views

CVE-2020-7494

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior formerly known as Vijeo XD which could cause malicious code execution when opening the project file...

7.8CVSS0.01347EPSS
SaveExploits0References1
Prion
Prion
•added 2020/06/16 8:15 p.m.•39 views

Sql injection

A CWE-89: Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior formerly known as Vijeo XD which could cause malicious code execution when opening the project file...

6.8CVSS8.2AI score0.01136EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder