Lucene search
+L

12 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•9 views

CVE-2019-16297: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the P4 tutorial application org.onosproject.p4tutorial, the host event listener does not handle the following event types: HOSTMOVED, HOSTREMOVED, HOSTUPDATED. In combination with other applications, this could lead to the...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/02/20 12:00 a.m.•8 views

PT-2020-9814

Name of the Vulnerable Software and Affected Versions Open Network Operating System ONOS version 1.14 Description An issue was discovered in the virtual tenant network application org.onosproject.vtn where the host event listener does not handle the HOST MOVED event type. This could lead to the...

7.5CVSS0.01673EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2020/02/20 12:00 a.m.•7 views

PT-2020-9815

Name of the Vulnerable Software and Affected Versions Open Network Operating System ONOS version 1.14 Description An issue was discovered in the Ethernet VPN application, specifically in the host event listener, which does not handle the event types HOST MOVED and HOST UPDATED. This could lead to...

7.5CVSS0.01673EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•7 views

CVE-2019-16301: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the virtual tenant network application org.onosproject.vtn, the host event listener does not handle the following event types: HOSTMOVED. In combination with other applications, this could lead to the absence of intended code...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•8 views

CVE-2019-16300: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the access control application org.onosproject.acl, the host event listener does not handle the following event types: HOSTREMOVED. In combination with other applications, this could lead to the absence of intended code...

7.5CVSS7.3AI score0.02004EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•8 views

CVE-2019-16298: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the virtual broadband network gateway application org.onosproject.virtualbng, the host event listener does not handle the following event types: HOSTMOVED, HOSTREMOVED, HOSTUPDATED. In combination with other applications, this...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•5 views

CVE-2019-16299: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the mobility application org.onosproject.mobility, the host event listener does not handle the following event types: HOSTADDED, HOSTREMOVED, HOSTUPDATED. In combination with other applications, this could lead to the absence ...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/02/20 12:00 a.m.•5 views

PT-2020-9813

Name of the Vulnerable Software and Affected Versions Open Network Operating System ONOS version 1.14 Description An issue in the access control application org.onosproject.acl of Open Network Operating System ONOS causes the host event listener to not handle the HOST REMOVED event type. This cou...

7.5CVSS0.02004EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2020/02/20 12:00 a.m.•4 views

PT-2020-9812

Name of the Vulnerable Software and Affected Versions Open Network Operating System ONOS version 1.14 Description An issue was discovered in the mobility application org.onosproject.mobility where the host event listener does not handle the event types: HOST ADDED, HOST REMOVED, HOST UPDATED. Thi...

7.5CVSS0.01673EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2020/02/20 12:00 a.m.•6 views

PT-2020-9811

Name of the Vulnerable Software and Affected Versions Open Network Operating System ONOS version 1.14 Description An issue was discovered in the virtual broadband network gateway application, specifically in the host event listener, which does not handle certain event types, including HOST MOVED,...

7.5CVSS0.01673EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•6 views

CVE-2019-16302: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the Ethernet VPN application org.onosproject.evpnopenflow, the host event listener does not handle the following event types: HOSTMOVED, HOSTUPDATED. In combination with other applications, this could lead to the absence of...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2020/02/20 12:00 a.m.•6 views

PT-2020-9810

Name of the Vulnerable Software and Affected Versions Open Network Operating System ONOS version 1.14 Description An issue was discovered in the P4 tutorial application where the host event listener does not handle certain event types, including HOST MOVED, HOST REMOVED, and HOST UPDATED. This...

7.5CVSS0.01673EPSS
SaveExploits0References3
Rows per page
Query Builder