228 matches found
CVE-2020-7577
Siemens Opcenter Execution Core (and Camstar Enterprise Platform) contains CVE-2020-7577, an SQL Injection vulnerability exploitable by an authenticated user via manipulated input to the back-end server. Affected: Opcenter Execution Core versions prior to 8.2; Camstar/Opcenter stack broader scope...
CVE-2020-7577
A vulnerability has been identified in Camstar Enterprise Platform All versions, Opcenter Execution Core All versions V8.2. Through the use of several vulnerable fields of the application, an authenticated user could perform an SQL Injection attack by passing a modified SQL query downstream to th...
CVE-2020-7587
CVE-2020-7587 affects Siemens Opcenter and SIMATIC software (e.g., Opcenter Execution Discrete/Foundation/Process, Opcenter Intelligence, Opcenter RD&L, SIMATIC IT LMS/Production Suite, SIMATIC Notifier, PCSneo, STEP 7, SIMOCODE ES, Soft Starter ES, IT Production products). The vulnerability set ...
CVE-2020-7588
CVE-2020-7588 affects Siemens/SIEMENS-related products (Opcenter Execution Discrete/Foundation/Process, Intelligence, Quality, RD&L, SIMATIC IT LMS/Production Suite, Notifier Server, PCS neo, STEP 7 TI A Portal, SIMOCODE ES, Soft Starter ES). Root cause per PT-2020-6696 and CISA/NVD details: insu...
PT-2020-6695 · Siemens · Simocode Es +12
Name of the Vulnerable Software and Affected Versions: Opcenter Execution Discrete versions prior to V3.2 Opcenter Execution Foundation versions prior to V3.2 Opcenter Execution Process versions prior to V3.2 Opcenter Intelligence versions prior to V3.3 Opcenter Quality versions prior to V11.3...
Siemens Opcenter Execution Core (Update B)
1. EXECUTIVE SUMMARY CVSS v3 8.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: Opcenter Execution Core --------- Begin Update B Part 1 of 5 --------- Vulnerabilities: Cross-site Scripting, SQL Injection, Improper Access Control, Insufficiently Protected...
Siemens UMC Stack (Update H)
1. EXECUTIVE SUMMARY CVSS v3 6.7 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: UMC Stack Vulnerabilities: Unquoted Search Path or Element, Uncontrolled Resource Consumption, Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a...
PT-2020-6696 · Siemens · Simocode Es +12
Name of the Vulnerable Software and Affected Versions: Opcenter Execution Discrete versions prior to V3.2 Opcenter Execution Foundation versions prior to V3.2 Opcenter Execution Process versions prior to V3.2 Opcenter Intelligence versions prior to V3.3 Opcenter Quality versions prior to V11.3...