Lucene search
+L

320 matches found

Prion
Prion
•added 2019/07/03 4:15 p.m.•37 views

Design/Logic Flaw

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to...

5CVSS9.2AI score0.00906EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2019/07/03 4:15 p.m.•25 views

Memory corruption

There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425...

7.8CVSS8.7AI score0.0154EPSS
SaveExploits0References1Affected Software4
Prion
Prion
•added 2019/07/03 4:15 p.m.•21 views

Memory corruption

Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424...

7.5CVSS7.8AI score0.0154EPSS
SaveExploits0References1Affected Software4
CVE
CVE
•added 2019/07/03 3:25 p.m.•78 views

CVE-2018-11420

CVE-2018-11420 affects the Moxa OnCell G3100-HSPA Series web interface, specifically version 1.5 Build 17042015. The vulnerability is described as memory corruption in the web interface. The associated records list a high-severity impact (CVSS v2 base score 7.5; CVSS v3 base score 9.8) with netwo...

9.8CVSS7.8AI score0.0154EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/07/03 3:25 p.m.•46 views

CVE-2018-11420

There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423...

8.2AI score0.0154EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2019/07/03 3:24 p.m.•53 views

CVE-2018-11421

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to...

9.3AI score0.00906EPSS
SaveExploits0References1
CVE
CVE
•added 2019/07/03 3:24 p.m.•74 views

CVE-2018-11421

The CVE-2018-11421 entry affects Moxa OnCell G3100-HSPA Series, specifically version 1.6 Build 17100315 and prior. The root cause is a proprietary monitoring protocol that provides no confidentiality, integrity, or authenticity protections, sending information in plain text. Impact stated across ...

9.8CVSS9.1AI score0.00906EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/07/03 3:23 p.m.•35 views

CVE-2018-11422

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. Any commands including devi...

9.5AI score0.01022EPSS
SaveExploits0References1
CVE
CVE
•added 2019/07/03 3:23 p.m.•87 views

CVE-2018-11422

CVE-2018-11422 affects Moxa OnCell G3100-HSPA Series (versions 1.6 Build 17100315 and earlier). The vulnerability arises from a proprietary configuration protocol that provides no confidentiality, integrity, or authenticity—info is sent in plain text and can be intercepted or modified. Commands s...

9.8CVSS9.3AI score0.01022EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/07/03 3:22 p.m.•48 views

CVE-2018-11423

There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420...

8.2AI score0.0136EPSS
SaveExploits0References1
CVE
CVE
•added 2019/07/03 3:22 p.m.•72 views

CVE-2018-11423

CVE-2018-11423 affects the web interface of the Moxa OnCell G3100-HSPA Series (version 1.6 Build 17100315 and prior). The issue is described as memory corruption and is explicitly noted as a different vulnerability from CVE-2018-11420. Connected documents provide no additional technical details (...

7.8CVSS8.7AI score0.0136EPSS
SaveExploits0References1Affected Software1
OSV
OSV
•added 2019/07/03 3:15 p.m.•18 views

CVE-2018-11427

CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator...

8.8CVSS5.8AI score0.00579EPSS
SaveExploits0References1
OSV
OSV
•added 2019/07/03 3:15 p.m.•16 views

CVE-2018-11426

A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change...

9.8CVSS5.8AI score0.01841EPSS
SaveExploits0References1
NVD
NVD
•added 2019/07/03 3:15 p.m.•31 views

CVE-2018-11427

CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator...

8.8CVSS8.7AI score0.00579EPSS
SaveExploits0References1
NVD
NVD
•added 2019/07/03 3:15 p.m.•27 views

CVE-2018-11426

A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change...

9.8CVSS9.7AI score0.01841EPSS
SaveExploits0References1
Prion
Prion
•added 2019/07/03 3:15 p.m.•22 views

Cross site request forgery (csrf)

CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator...

6.8CVSS8.6AI score0.00579EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2019/07/03 3:15 p.m.•31 views

Authentication flaw

A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change...

7.5CVSS9.6AI score0.01841EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
•added 2019/07/03 3:11 p.m.•40 views

CVE-2018-11424

There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425...

8.2AI score0.0136EPSS
SaveExploits0References1
CVE
CVE
•added 2019/07/03 3:11 p.m.•77 views

CVE-2018-11424

CVE-2018-11424 affects the Moxa OnCell G3470A-LTE Series web interface (firmware 1.6 Build 18021314 and earlier). The root cause is memory corruption in the web interface, leading to availability impact as indicated by the CVSS metrics (HIGH). The CVE entry notes this is a different vulnerability...

7.8CVSS8.7AI score0.0136EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2019/07/03 3:09 p.m.•39 views

CVE-2018-11425

Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424...

8.2AI score0.0154EPSS
SaveExploits0References1
Rows per page
Query Builder