Lucene search
+L

128 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/01/23 12:00 a.m.•7 views

CVE-2025-67229: Improper Certificate Validation

An improper certificate validation vulnerability exists in ToDesktop Builder v0.32.1 This vulnerability allows an unauthenticated, on-path attacker to spoof backend responses by exploiting insufficient certificate validation...

9.8CVSS5.8AI score0.00266EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/23 12:00 a.m.•34 views

CVE-2025-67229

ToDesktop Builder version 0.32.1 is susceptible to an improper certificate validation vulnerability. Due to insufficient certificate verification, an unauthenticated, on-path attacker can spoof backend responses. While exploitation details and specific exploit links are not provided, the vulnerab...

9.8CVSS5.8AI score0.00266EPSS
SaveExploits0References2Affected Software1
NVD
NVD
•added 2025/12/16 1:15 a.m.•164 views

CVE-2025-14758

Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials...

6.5CVSS0.00184EPSS
SaveExploits0References1
CVE
CVE
•added 2025/12/16 12:33 a.m.•34 views

CVE-2025-14758

The CVE-2025-14758 entry concerns the YAOOK Operator’s infra-operator, where a misconfiguration in the replication security of the MariaDB component could allow an on-path attacker to read database contents, potentially including credentials. This is documented across multiple feeds (NVD, Red Hat...

6.5CVSS5.8AI score0.00184EPSS
SaveExploits0References1
EUVD
EUVD
•added 2025/12/16 12:33 a.m.•17 views

EUVD-2025-203480

Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials...

6.5CVSS5.8AI score0.00184EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2025/12/16 12:00 a.m.•24 views

PT-2025-51347

Name of the Vulnerable Software and Affected Versions YAOOK Operator affected versions not specified Description An incorrect configuration of replication security within the MariaDB component of the infra-operator in YAOOK Operator could allow an on-path attacker to read database contents, which...

6.5CVSS5.7AI score0.00184EPSS
SaveExploits0References5
osv_cve
osv_cve
•added 2025/11/13 5:32 p.m.•22 views

CVE-2025-59480 Inadequate validation of SSO redirect credentials permits credential theft

Mattermost Mobile Apps versions =2.32.0 fail to verify that SSO redirect tokens originate from the trusted server, which allows a malicious Mattermost instance or on-path attacker to obtain user session credentials via crafted token-in-URL responses...

6.1CVSS6.2AI score0.00154EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2025/11/13 5:32 p.m.•32 views

CVE-2025-59480 Inadequate validation of SSO redirect credentials permits credential theft

Mattermost Mobile Apps versions =2.32.0 fail to verify that SSO redirect tokens originate from the trusted server, which allows a malicious Mattermost instance or on-path attacker to obtain user session credentials via crafted token-in-URL responses...

6.1CVSS0.00154EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/11/13 12:00 a.m.•11 views

CVE-2025-59480: Cross-Site Request Forgery (CSRF)

Mattermost Mobile Apps versions =2.32.0 fail to verify that SSO redirect tokens originate from the trusted server, which allows a malicious Mattermost instance or on-path attacker to obtain user session credentials via crafted token-in-URL responses...

6.5CVSS6.2AI score0.00154EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/10/15 9:54 a.m.•26 views

CVE-2011-20002

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...

8.3CVSS7.4AI score0.00306EPSS
SaveExploits0References1
NVD
NVD
•added 2025/10/14 10:15 a.m.•29 views

CVE-2011-20002

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...

8.3CVSS0.00306EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2025/10/14 9:14 a.m.•28 views

CVE-2011-20002

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...

8.3CVSS0.00306EPSS
SaveExploits0References1
CVE
CVE
•added 2025/10/14 9:14 a.m.•31 views

CVE-2011-20002

Affected software/hardware: Siemens SIMATIC S7-1200 CPU V1/V2 families (incl. SIPLUS variants). Vulnerability: Capture-replay of engineering software communication that can allow an on-path attacker to replay legitimate commands to the controller. Root cause (from sources): Insecure handling of e...

8.3CVSS5.9AI score0.00306EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2025/10/14 9:14 a.m.•80 views

CVE-2011-20002

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...

8.3CVSS5.9AI score0.00306EPSS
SaveExploits0References1
EUVD
EUVD
•added 2025/10/14 9:14 a.m.•27 views

EUVD-2011-5261

A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family incl. SIPLUS variants All versions V2.0.2, SIMATIC S7-1200 CPU V2 family incl. SIPLUS variants All versions V2.0.2. Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This...

8.3CVSS7AI score0.00306EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2024/08/13 8:15 a.m.•14 views

CVE-2024-41681

A vulnerability has been identified in Location Intelligence family All versions V4.4. The web server of affected products is configured to support weak ciphers by default. This could allow an unauthenticated attacker in an on-path position to to read and modify any data passed over the connectio...

7.5CVSS5.7AI score0.00161EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2024/08/13 12:00 a.m.•23 views

PT-2024-7640 · Unknown · Location Intelligence

Name of the Vulnerable Software and Affected Versions: Location Intelligence versions prior to V4.4 Description: The issue is related to insufficiently strong data encryption. This could allow an unauthenticated attacker in an on-path position to read and modify any data passed over the connectio...

7.5CVSS7.2AI score0.00161EPSS
SaveExploits0References7
CVE
CVE
•added 2024/07/09 10:57 a.m.•69 views

CVE-2024-5631

Summary (verified by provided sources): CVE-2024-5631 affects Longse LBH30FE200W cameras and related devices (e.g., NVR3608PGE2W family). The issue enables credential exposure because login/password are transmitted to a remote control service without encryption when a user changes their password,...

6CVSS7.2AI score0.00208EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
•added 2024/07/09 10:57 a.m.•11 views

CVE-2024-5631

Longse NVR Network Video Recorder model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the...

6CVSS7.4AI score0.00208EPSS
SaveExploits0References3
SUSE CVE
SUSE CVE
•added 2023/02/15 4:16 a.m.•11 views

SUSE CVE-2019-6475

Mirror zones are a BIND feature allowing recursive servers to pre-cache zone data provided by other servers. A mirror zone is similar to a zone of type secondary, except that its data is subject to DNSSEC validation before being used in answers, as if it had been looked up via traditional...

5.9CVSS6.5AI score0.01337EPSS
SaveExploits0References4
Rows per page
Query Builder