Lucene search
+L

71 matches found

CVE
CVE
•added 2018/05/03 6:00 p.m.•66 views

CVE-2018-10167

TP-Link EAP Controller and Omada Controller (Windows) versions 2.5.4_Windows and 2.6.0_Windows are affected by CVE-2018-10167 due to a hard-coded cryptographic key used to encrypt the web app backup file. A low-privilege user can decrypt and modify the backup to escalate privileges, including cre...

7.5CVSS7.5AI score0.01148EPSS
SaveExploits3References2Affected Software1
Cvelist
Cvelist
•added 2018/05/03 6:00 p.m.•37 views

CVE-2018-10167

The web application backup file in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows is encrypted with a hard-coded cryptographic key, so anyone who knows that key and the algorithm can decrypt it. A low-privilege user could decrypt and modify the backup file in...

7.6AI score0.01148EPSS
SaveExploits3References2
Cvelist
Cvelist
•added 2018/05/03 6:00 p.m.•37 views

CVE-2018-10168

TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows do not control privileges for usage of the Web API, allowing a low-privilege user to make any request as an Administrator. This is fixed in version 2.6.1Windows...

8.6AI score0.01496EPSS
SaveExploits3References2
Cvelist
Cvelist
•added 2018/05/03 6:00 p.m.•39 views

CVE-2018-10165

Stored Cross-site scripting XSS vulnerability in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows allows authenticated attackers to inject arbitrary web script or HTML via the userName parameter in the local user creation functionality. This is fixed in version...

5.8AI score0.00585EPSS
SaveExploits3References2
CVE
CVE
•added 2018/05/03 6:00 p.m.•60 views

CVE-2018-10164

Summary: CVE-2018-10164 is a stored XSS vulnerability in TP-Link EAP Controller and Omada Controller. Affected versions are 2.5.4_Windows and 2.6.0_Windows. The issue arises via portalPictureUpload, enabling an authenticated attacker to inject arbitrary web script/HTML. TP-Link fixed the flaw in ...

5.4CVSS5.6AI score0.00604EPSS
SaveExploits3References2Affected Software1
CVE
CVE
•added 2018/05/03 6:00 p.m.•66 views

CVE-2018-10166

The CVE-2018-10166 issue affects TP-Link EAP Controller and Omada Controller (versions 2.5.4_Windows / 2.6.0_Windows). The web management interface lacks Anti-CSRF tokens in forms, enabling authenticated actions from a user visiting a controlled domain. Core Security details confirm PoCs: ability...

8.8CVSS8.4AI score0.00708EPSS
SaveExploits3References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/03 12:00 a.m.•1 views

CVE-2018-10167: Use of Hard-coded Credentials

The web application backup file in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows is encrypted with a hard-coded cryptographic key, so anyone who knows that key and the algorithm can decrypt it. A low-privilege user could decrypt and modify the backup file in...

7.5CVSS7.3AI score0.01148EPSS
SaveExploits3References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/03 12:00 a.m.•1 views

CVE-2018-10168: Improper Privilege Management

TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows do not control privileges for usage of the Web API, allowing a low-privilege user to make any request as an Administrator. This is fixed in version 2.6.1Windows...

8.8CVSS7.7AI score0.01496EPSS
SaveExploits3References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/03 12:00 a.m.•2 views

CVE-2018-10164: Improper Neutralization of Input During Web Page Generation

Stored Cross-site scripting XSS vulnerability in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows allows authenticated attackers to inject arbitrary web script or HTML via the implementation of portalPictureUpload functionality. This is fixed in version...

5.4CVSS6.4AI score0.00604EPSS
SaveExploits3References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/03 12:00 a.m.•3 views

CVE-2018-10166: Cross-Site Request Forgery (CSRF)

The web management interface in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows does not have Anti-CSRF tokens in any forms. This would allow an attacker to submit authenticated requests when an authenticated user browses an attack-controlled domain. This is fix...

8.8CVSS7.7AI score0.00708EPSS
SaveExploits3References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/03 12:00 a.m.•3 views

CVE-2018-10165: Improper Neutralization of Input During Web Page Generation

Stored Cross-site scripting XSS vulnerability in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows allows authenticated attackers to inject arbitrary web script or HTML via the userName parameter in the local user creation functionality. This is fixed in version...

5.4CVSS6.4AI score0.00585EPSS
SaveExploits3References2
Rows per page
Query Builder