14073 matches found
CVE-2026-14802: Improper Neutralization of Special Elements used in an OS Command
A vulnerability was detected in react create-react-app up to 5.0.1 on macOS. This affects the function startBrowserProcess of the file openBrowser.js of the component react-dev-utils. Performing a manipulation results in os command injection. Remote exploitation of the attack is possible. The...
CVE-2026-42153: Improper Neutralization of Special Elements used in an OS Command
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. Prior to 4.0.0-beta.474, PostgreSQL healthcheck command generation used attacker-controlled database settings postgresuser and postgresdb in shell-form commands, allowing an authenticated user to...
CVE-2026-42204: Improper Neutralization of Special Elements used in an OS Command
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. From 4.0.0-beta.471 through 4.0.0-beta.473, a regression in SHELLSAFECOMMANDPATTERN allowed ampersands in custom Docker Compose build, start, and pre/post-deployment command fields, allowing an...
CVE-2026-34049: Improper Neutralization of Special Elements used in an OS Command
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. From 4.0.0-beta.451 through 4.0.0-beta.470, database backup handling for MongoDB collection names did not fully validate shell metacharacters, allowing a highly privileged attacker who can configur...
CVE-2026-34153: Improper Neutralization of Special Elements used in an OS Command
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. Prior to 4.0.0-beta.471, LocalFileVolume::saveStorageOnServer builds shell commands using unescaped fspath and parentdir values before validation, and submitFileStorage does not validate the...
CVE-2026-55798: Improper Neutralization of Special Elements used in an OS Command
Pillow is a Python imaging library. Prior to 12.3.0, WindowsViewer.getcommand constructed a cmd.exe shell command by directly embedding a file path into an f-string without escaping and passed the result to subprocess.Popen..., shell=True, allowing shell metacharacters in the file path to inject...
CVE-2026-6382: Undefined Security Weakness
The FileOrganizer WordPress plugin before 1.1.9, Advanced File Manager WordPress plugin before 5.4.12, File Manager Pro WordPress plugin before 2.1.1, File Manager WordPress plugin before 8.0.4 do not properly escape a parameter before passing it to a shell command when processing image operation...
CVE-2026-49815
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command 'OS...
CVE-2026-53478
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command 'OS...
EUVD-2026-41553
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command 'OS...
CVE-2026-49814
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command 'OS...
CVE-2026-49814
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an Improper Neutralization of Special Elements used in an OS Command 'OS...
CVE-2026-49814
CVE-2026-49814 affects Dell PowerProtect Data Domain, including versions 7.7.1.0–8.7 and several LTS releases (8.6.1.0–8.6.1.10, 8.3.1.0–8.3.1.30, 7.13.1.0–7.13.1.70). The vulnerability is an OS Command Injection due to improper neutralization of special elements, allowing a high-privilege, remot...
CVE-2026-49815
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command 'OS...
EUVD-2026-41549
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command 'OS...
CVE-2026-53478
Summary: CVE-2026-53478 affects Dell PowerProtect Data Domain (versions 7.7.1.0–8.7; LTS2026: 8.6.1.0–8.6.1.10; LTS2025: 8.3.1.0–8.3.1.30; LTS2024: 7.13.1.0–7.13.1.70) and is caused by improper neutralization of special elements used in an OS command (OS command injection). A high-privilege attac...
CVE-2026-53478
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command 'OS...
CVE-2026-54483
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special elements used in an OS command 'OS...
EUVD-2026-41537
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command 'OS...
CVE-2026-26355
Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command 'OS...