Lucene search
+L

13744 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•3 views

CVE-2026-19983: Improper Neutralization of Special Elements used in an OS Command

A vulnerability was detected in GL.iNet A1300, AX1800, AXT1800, MT2500, MT3000, MT6000, X3000 and XE3000 4.8.x. This issue affects some unknown processing of the file /usr/bin/glnassys of the component NAS Command Service. The manipulation results in os command injection. The attack may be launch...

8.3CVSS5.5AI score0.0206EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/17 12:00 a.m.•24 views

PT-2026-76657

Name of the Vulnerable Software and Affected Versions Dell ObjectScale versions prior to 4.3.0.1 Description An OS Command Injection issue exists due to improper neutralization of special elements used in an OS command. A low privileged attacker with local access could exploit this flaw to execut...

7.3CVSS5.9AI score0.00718EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-67965: Improper Neutralization of Special Elements used in an OS Command

An issue in Tneda W20E v.16.01.0.62782 allows a remote attacker to execute arbitrary code via the urlneedlogin function...

9.8CVSS6.5AI score0.0086EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-68519: Improper Neutralization of Special Elements used in an OS Command

Glances is an open-source system cross-platform monitoring tool. Prior to 4.5.6, GlancesActions.run in glances/actions.py ignores --disable-config-exec for on-alert action commands and invokes securepopen with shell operators enabled, allowing configured redirection, command chaining, or pipes to...

7.1CVSS6.1AI score0.00178EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•2 views

CVE-2026-19978: Improper Neutralization of Special Elements used in an OS Command

A flaw has been found in jiantao88 android-mcp-server up to cfb872b2446794193b58edd63f4dbf6af48a6292. The impacted element is the function childprocess.exec of the file build/index.js of the component Command Execution. Executing a manipulation of the argument...

5.3CVSS5.2AI score0.01196EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-59910: Improper Neutralization of Special Elements used in an OS Command

Dell ObjectScale, versions prior to 4.3.0.1, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges...

7.8CVSS5.9AI score0.00647EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-75056: Improper Neutralization of Special Elements used in an OS Command

In JetBrains IntelliJ IDEA before 2026.2.1 rCE via Markdown export tool was possible...

7.8CVSS5.7AI score0.00194EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•2 views

CVE-2026-62982: Improper Neutralization of Special Elements used in an OS Command

Glances is an open-source system cross-platform monitoring tool. From 4.5.2 until 4.5.6, sanitizemustachedict in glances/actions.py skips nested list and dictionary strings such as process cmdline values, allowing pipe characters to survive chevron.render and be executed by securepopen through...

8.8CVSS5.8AI score0.00197EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/08/17 12:00 a.m.•19 views

PT-2026-76659

Name of the Vulnerable Software and Affected Versions Dell ObjectScale versions prior to 4.3.0.1 Description An OS Command Injection issue exists due to the improper neutralization of special elements used in an OS command. A low privileged attacker with local access could exploit this flaw to...

7.8CVSS5.3AI score0.00647EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•2 views

CVE-2026-56685: Improper Neutralization of Special Elements used in an OS Command

Dell ObjectScale, versions prior to 4.3.0.1, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution...

7.3CVSS5.9AI score0.00718EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/17 12:00 a.m.•28 views

PT-2026-73202

A vulnerability was detected in GL.iNet A1300, AX1800, AXT1800, MT2500, MT3000, MT6000, X3000 and XE3000 4.8.x. This issue affects some unknown processing of the file /usr/bin/gl nas sys of the component NAS Command Service. The manipulation results in os command injection. The attack may be...

8.3CVSS7.7AI score0.0206EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-74801: Improper Neutralization of Special Elements used in an OS Command

SiYuan before 3.7.4 fails to properly escape workspace directory paths when constructing command-line arguments for the elevated elevator.exe helper process. Attackers can create a malicious workspace directory with command metacharacters in its path and trigger the Microsoft Defender exclusion...

8.6CVSS6.4AI score0.00205EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•2 views

CVE-2026-19982: Improper Neutralization of Special Elements used in an OS Command

A security vulnerability has been detected in GL.iNet BE9300 and MT6000 4.8.x. This vulnerability affects unknown code of the component Firewall-management RPC. The manipulation of the argument destport/destip leads to os command injection. The attack may be initiated remotely. Upgrading to versi...

7.4CVSS5.5AI score0.01768EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•2 views

CVE-2026-71567: Improper Neutralization of Special Elements used in an OS Command

In openshift-metal3/fakefish there is a repeated pattern in some of the scripts where shell variables are injected without quoting them either into command lines or into manifests. This mostly applies to the Image URL and BMC credentials which are not verified by FakeFish...

7.7CVSS5.8AI score0.00336EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•2 views

CVE-2026-56686: Improper Neutralization of Special Elements used in an OS Command

Dell ObjectScale, versions prior to 4.3.0.1, contains an Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges...

7.8CVSS5.9AI score0.00647EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2026/08/17 12:00 a.m.•21 views

PT-2026-76658

Name of the Vulnerable Software and Affected Versions Dell ObjectScale versions prior to 4.3.0.1 Description An OS Command Injection issue exists due to improper neutralization of special elements used in an OS command. A low privileged attacker with local access could exploit this flaw to achiev...

7.8CVSS5.3AI score0.00647EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-68518: Improper Neutralization of Special Elements used in an OS Command

Glances is an open-source system cross-platform monitoring tool. Prior to 4.5.6, sanitizemustachedict in glances/actions.py sanitizes individual Mustache values before chevron.render, allowing adjacent unescaped Mustache variables to reconstruct shell operators that securepopen executes when...

8.8CVSS5.8AI score0.00173EPSS
SaveExploits0References2
Exploit DB
Exploit DB
•added 2026/08/17 12:00 a.m.•28 views

D-Link DNS_340L - OS Command Injection

Exploit Title: D-Link DNS340L - OS Command Injection Date: 2026-07-16 Exploit Author: Jared Brits K3ysTr0K3R Vendor Homepage: https://www.dlink.com/ Version: DNS-320 v1.00, DNS-320LW v1.01.0914.2012, DNS-325 v1.01, v1.02, DNS-340L v1.08, and possibly others Tested on: D-Link DNS-320 CVE:...

9.8CVSS8.2AI score0.96284EPSS
SaveExploits13
Positive Technologies
Positive Technologies
•added 2026/08/17 12:00 a.m.•18 views

PT-2026-73200

A weakness has been identified in GL.iNet A1300, AX1800, AXT1800, BE1400, BE3600, BE6500, BE9300, BE10000, E5800, MT2500, MT3000, MT3600BE, MT5000, MT6000, X2000, X3000 and XE3000 up to 4.8.x. This affects an unknown part of the component Wi-Fi Timer Power-Schedule Feature. Executing a manipulati...

7.4CVSS7.2AI score0.01768EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/17 12:00 a.m.•1 views

CVE-2026-19981: Improper Neutralization of Special Elements used in an OS Command

A weakness has been identified in GL.iNet A1300, AX1800, AXT1800, BE1400, BE3600, BE6500, BE9300, BE10000, E5800, MT2500, MT3000, MT3600BE, MT5000, MT6000, X2000, X3000 and XE3000 up to 4.8.x. This affects an unknown part of the component Wi-Fi Timer Power-Schedule Feature. Executing a manipulati...

7.4CVSS5.5AI score0.01768EPSS
SaveExploits0References3
Rows per page
Query Builder