225 matches found
PT-2025-32639 · Smartclient · Smartclient Opcenter Ql Home +2
Name of the Vulnerable Software and Affected Versions: SmartClient Opcenter QL Home SC versions 13.2 through 2505 SmartClient SOA Audit versions 13.2 through 2505 SmartClient SOA Cockpit versions 13.2 through 2505 Description: The affected application does not encrypt communication in the LDAP...
Siemens多款产品 代码问题漏洞
Siemens SmartClient modules Opcenter QL Home is a client module from Siemens Germany. A code issue vulnerability exists in various Siemens products, which stems from an unexpired session that could lead to unauthorized access. The following products and versions are affected: SmartClient modules...
Siemens多款产品 安全漏洞
Siemens SmartClient modules Opcenter QL Home is a client module from Siemens Germany. A security vulnerability exists in various Siemens products that stems from insufficient encryption of sensitive information, which could lead to the disclosure of sensitive information. The following products a...
PT-2025-32641 · Smartclient · Soa Audit +2
Name of the Vulnerable Software and Affected Versions: SmartClient Opcenter QL Home SC versions 13.2 through 2505 SmartClient SOA Audit versions 13.2 through 2505 SmartClient SOA Cockpit versions 13.2 through 2505 Description: The affected application displays SQL statements in error messages...
Siemens多款产品 加密问题漏洞
Siemens SmartClient modules Opcenter QL Home is a client module from Siemens Germany. A vulnerability exists in various Siemens products due to an encryption issue that stems from support for the insecure TLS protocol, which could lead to a man-in-the-middle attack. The following products and...
PT-2025-32644 · Smartclient · Smartclient Opcenter Ql Home +2
Name of the Vulnerable Software and Affected Versions: SmartClient Opcenter QL Home SC versions 13.2 through 2505 SmartClient SOA Audit versions 13.2 through 2505 SmartClient SOA Cockpit versions 13.2 through 2505 Description: The affected application supports insecure TLS 1.0 and 1.1 protocols...
Siemens SmartClient modules Opcenter QL Home 安全漏洞
Siemens SmartClient modules Opcenter QL Home is a client module from Siemens, Germany. A security vulnerability exists in Siemens SmartClient modules Opcenter QL Home, which stems from unencrypted LDAP communication and could lead to the disclosure of sensitive information...
Siemens Opcenter Quality
SUMMARY The Opcenter Quality is affected by multiple vulnerabilities in the SmartClient modules Opcenter QL Home SC, SOA Audit and SOA Cockpit. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general...
CVE-2023-46281
A vulnerability has been identified in Opcenter Execution Foundation All versions V2407, Opcenter Quality All versions V2312, SIMATIC PCS neo All versions V4.1, SINEC NMS All versions V2.0 SP1, Totally Integrated Automation Portal TIA Portal V14 All versions, Totally Integrated Automation Portal...
CVE-2023-46284
A vulnerability has been identified in Opcenter Execution Foundation All versions V2407, Opcenter Quality All versions V2312, SIMATIC PCS neo All versions V4.1, SINEC NMS All versions V2.0 SP1, Totally Integrated Automation Portal TIA Portal V14 All versions, Totally Integrated Automation Portal...
CVE-2022-33736
A vulnerability has been identified in Opcenter Quality V13.1 All versions V13.1.20220624, Opcenter Quality V13.2 All versions V13.2.20220624. The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing...
CVE-2020-7587
A vulnerability has been identified in Opcenter Execution Discrete All versions V3.2, Opcenter Execution Foundation All versions V3.2, Opcenter Execution Process All versions V3.2, Opcenter Intelligence All versions V3.3, Opcenter Quality All versions V11.3, Opcenter RD V8.0, SIMATIC IT LMS All...
CVE-2020-7588
A vulnerability has been identified in Opcenter Execution Discrete All versions V3.2, Opcenter Execution Foundation All versions V3.2, Opcenter Execution Process All versions V3.2, Opcenter Intelligence All versions V3.3, Opcenter Quality All versions V11.3, Opcenter RD V8.0, SIMATIC IT LMS All...
CVE-2020-7578
A vulnerability has been identified in Camstar Enterprise Platform All versions, Opcenter Execution Core All versions V8.2. Authenticated users could have access to resources they normally would not have. This vulnerability could allow an attacker to view internal information and perform...
CVE-2020-28390
A vulnerability has been identified in Opcenter Execution Core V8.2, Opcenter Execution Core V8.3. The application contains an information leakage vulnerability in the handling of web client sessions. A local attacker who has access to the Web Client Session Storage could disclose the passwords o...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in several products such as APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC and Teamcenter. The vulnerabilities potentially enable a malicious person to carry out attacks that could lead to the following categories of damage: - Denial-of-Service DoS -...
CISA Releases Twenty Industrial Control Systems Advisories
CISA released twenty Industrial Control Systems ICS advisories on February 13, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-044-01 Siemens SIMATIC S7-1200 CPU Family ICSA-25-044-02 Siemens SIMATIC...
Vulnerabilities fixed in Siemens products
Siemens has fixed vulnerabilities in several products such as APOGEE, Opcenter, RUGGEDCOM, SCALANCE, SIMATIC, SIPROTEC and Teamcenter. The vulnerabilities potentially enable a malicious person to carry out attacks that could lead to the following categories of damage: - Denial-of-Service DoS -...