Siemens SIMATIC WinCC using obsolete function vulnerability
SIMATIC NET PC software is a separately sold software product that implements the SIMATIC NET communication products.SIMATIC PCS 7 is a centralized control system DCS that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components.SIMATIC WinCC is a Supervisory...
CVE-2023-28829
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
CVE-2023-28829
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
Authentication flaw
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
CVE-2023-28829
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
CVE-2023-28829
CVE-2023-28829 concerns Siemens SIMATIC WinCC/PCS7/NET PC software. The root cause is use of legacy OPC services (OPC DA/HDA/AE) built on Windows ActiveX/DCOM that lack modern authentication and encryption. Affected: SIMATIC NET PC Software V14/V15, SIMATIC PCS 7 V8.2/V9.0/V9.1, SIMATIC WinCC (al...
CVE-2023-28829
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
CVE-2023-28829: Use of Obsolete Function
A vulnerability has been identified in SIMATIC NET PC Software V14 All versions, SIMATIC NET PC Software V15 All versions, SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions, SIMATIC PCS 7 V9.1 All versions, SIMATIC WinCC All versions V8.0, SINAUT Software ST7sc All versions. Before...
PT-2023-3622 · Microsoft +1 · Windows +6
Name of the Vulnerable Software and Affected Versions: SIMATIC NET PC Software versions V14 through V15 SIMATIC PCS 7 versions V8.2 through V9.1 SIMATIC WinCC versions prior to V8.0 SINAUT Software ST7sc affected versions not specified Description: The issue is related to the use of outdated...
(Pwn2Own) Prosys OPC UA Simulation Server OpenSecureChannel Resource Exhaustion Denial-of-Service Vulnerability
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Prosys OPC UA Simulation Server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OpenSecureChannel messages. By sending a...
Schneider Electric OPC Factory Server XML External Entity Injection Vulnerability
Schneider Electric OPC Factory Server is a software application from the French company Schneider Electric Schneider Electric. An XML external entity injection vulnerability exists in Schneider Electric OPC Factory Server, which stems from an improper restriction on XML external entity references...
(Pwn2Own) Prosys OPC UA Simulation Server Resource Exhaustion Denial-of-Service Vulnerability
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Prosys OPC UA Simulation Server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of message chunks. By sending a large number ...
Schneider Electric OPC Factory Server 代码问题漏洞
Schneider Electric OPC Factory Server is a software application from the French company Schneider Electric Schneider Electric. An XML external entity injection vulnerability exists in Schneider Electric OPC Factory Server, which stems from an improper restriction on XML external entity references...
CVE-2023-32787
The OPC UA Legacy Java Stack before 6f176f2 enables an attacker to block OPC UA server applications via uncontrolled resource consumption so that they can no longer serve client applications...
CVE-2023-32787
The OPC UA Legacy Java Stack before 6f176f2 enables an attacker to block OPC UA server applications via uncontrolled resource consumption so that they can no longer serve client applications...
CVE-2023-32787
The OPC UA Legacy Java Stack before 6f176f2 enables an attacker to block OPC UA server applications via uncontrolled resource consumption so that they can no longer serve client applications...
Code injection
The OPC UA Legacy Java Stack before 6f176f2 enables an attacker to block OPC UA server applications via uncontrolled resource consumption so that they can no longer serve client applications...
CVE-2023-32787
CVE-2023-32787 affects the OPC UA Legacy Java Stack prior to 6f176f2. It enables an attacker to cause denial of service via uncontrolled resource consumption, blocking OPC UA server applications from servicing clients. The issue is network‑feasible (per CVSS) and the documented fix is to update t...