Lucene search
+L

190 matches found

NVD
NVD
added 2022/09/14 6:15 p.m.28 views

CVE-2022-29922

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the...

7.5CVSS0.00697EPSS
SaveExploits0References1
Prion
Prion
added 2022/09/14 6:15 p.m.18 views

Input validation

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the...

5CVSS7.5AI score0.00697EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/09/14 5:3 p.m.78 views

CVE-2022-29922

Summary: CVE-2022-29922 is an improper input validation flaw in Hitachi Energy MicroSCADA X SYS600 and MicroSCADA Pro SYS600, specifically in the IEC 61850 OPC Server handling a packet with a valid data item but incorrect data type, potentially causing a denial-of-service. Affected versions: Micr...

7.5CVSS7.6AI score0.00697EPSS
SaveExploits0References1Affected Software1
BDU FSTEC
BDU FSTEC
added 2022/08/26 12:0 a.m.12 views

The vulnerability of the display on the iHistorian Data Display OPC-server for WorkstationST allows a attacker to perform XSS attacks.

The vulnerability of the iHistorian Data Display OPC-server workstation exists due to the lack of measures taken to protect the website structure. Exploiting this vulnerability allows a malicious actor to carry out XSS attacks remotely...

6.4CVSS5.4AI score0.00328EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2022/05/26 5:15 p.m.37 views

CVE-2022-1261

Matrikon, a subsidary of Honeywell Matrikon OPC Server all versions is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges...

9CVSS0.00651EPSS
SaveExploits0References1
Prion
Prion
added 2022/05/26 5:15 p.m.18 views

Design/Logic Flaw

Matrikon, a subsidary of Honeywell Matrikon OPC Server all versions is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges...

9CVSS8.6AI score0.00651EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2022/05/26 4:35 p.m.6 views

CVE-2022-1261 Matrikon OPC Server Improper Access Control

Matrikon, a subsidary of Honeywell Matrikon OPC Server all versions is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges...

5.8CVSS7AI score0.00651EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/05/26 4:35 p.m.33 views

CVE-2022-1261 Matrikon OPC Server Improper Access Control

Matrikon, a subsidary of Honeywell Matrikon OPC Server all versions is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges...

5.8CVSS8.8AI score0.00651EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2022/05/24 12:0 a.m.6 views

Honeywell Matrikon OPC Server 访问控制错误漏洞

Honeywell Matrikon OPC Server is a powerful tool from Honeywell, Inc. to securely access your control and automation systems and open up new horizons of connectivity for other systems. An Access Control Error vulnerability exists in Honeywell Matrikon OPC Server, which stems from a restriction in...

9CVSS8AI score0.00651EPSS
SaveExploits0References4
ICS
ICS
added 2022/05/24 12:0 a.m.81 views

Matrikon OPC Server

1. EXECUTIVE SUMMARY CVSS v3 5.8 ATTENTION: Exploitable remotely Vendor: Matrikon, a subsidiary of Honeywell Equipment: Matrikon OPC Server Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve remote command...

9CVSS7.7AI score0.00651EPSS
SaveExploits0References5
OSV
OSV
added 2022/05/23 7:16 p.m.7 views

CVE-2021-32935

The affected Cognex product, the In-Sight OPC Server versions v5.7.4 96 and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation...

9.8CVSS5.8AI score0.01768EPSS
SaveExploits0References1
Prion
Prion
added 2022/05/23 7:16 p.m.20 views

Privilege escalation

The affected Cognex product, the In-Sight OPC Server versions v5.7.4 96 and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation...

10CVSS9.2AI score0.01768EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2022/05/23 6:42 p.m.15 views

CVE-2021-32935 Cognex In-Sight OPC Server - Deserialization of Untrusted Data

The affected Cognex product, the In-Sight OPC Server versions v5.7.4 96 and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation...

8.8CVSS9.3AI score0.01768EPSS
SaveExploits0References1
CVE
CVE
added 2022/05/23 6:42 p.m.80 views

CVE-2021-32935

CVE-2021-32935 affects Cognex In-Sight OPC Server (v5.7.4 (96) and prior). The vulnerability is Deserialization of Untrusted Data (CWE-502) in the OPC Server, allowing a remote attacker to execute system-level commands and achieve local privilege escalation. CVSS v3.1 base score 9.8 (CRITICAL) pe...

10CVSS9.2AI score0.01768EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/05/23 6:42 p.m.21 views

CVE-2021-32935 Cognex In-Sight OPC Server - Deserialization of Untrusted Data

The affected Cognex product, the In-Sight OPC Server versions v5.7.4 96 and prior, deserializes untrusted data, which could allow a remote attacker access to system level permission commands and local privilege escalation...

8.8CVSS9.5AI score0.01768EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2022/04/07 12:0 a.m.11 views

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to execute arbitrary commands.

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, is related to authentication process flaws. Exploiting this vulnerability could allow attackers...

7.1CVSS7.9AI score0.0093EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2022/04/07 12:0 a.m.9 views

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to write arbitrary files.

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, is related to errors in processing the relative path to the catalog. Exploiting this...

5.9CVSS7.5AI score0.00922EPSS
SaveExploits0References3
ICS
ICS
added 2022/03/15 12:0 a.m.50 views

ABB OPC Server for AC 800M

1. EXECUTIVE SUMMARY CVSS v3 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: OPC Server for AC 800M Vulnerability: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a low privileged authenticated...

8.8CVSS8.9AI score0.00831EPSS
SaveExploits0References5
NCSC
NCSC
added 2022/02/10 12:0 a.m.6 views

Vulnerability fixed in ABB OPC Server for AC 800M

ABB has fixed a vulnerability in OPC Server for AC 800M systems. The vulnerability allows an authenticated malicious person with network access to the vulnerable system able to execute arbitrary code. Few substantive details about the vulnerability made publicly available. ABB has released update...

8.8CVSS7.3AI score0.00831EPSS
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2022/02/07 12:0 a.m.8 views

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to execute arbitrary codes.

The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, lies in the loading of a non-existent dynamic library. Exploiting this vulnerability could allo...

8.3CVSS7.5AI score0.00216EPSS
SaveExploits0References3
Rows per page
Query Builder