CVE-2026-50610
CVE-2026-50610 affects the Acer System Monitoring component bundled with NitroSense and PredatorSense software. The root cause is insufficient access controls in a privileged service , allowing an authenticated local user to access the service and perform unauthorized registry modifications , pot...
EUVD-2026-81402
A vulnerability has been identified in the Acer System Monitoring component included with NitroSense and PredatorSense due to insufficient access controls in a privileged service. An authenticated local user may be able to access the service and perform unauthorized registry modifications,...
CVE-2026-50607
CVE-2026-50607 affects the Acer System Monitoring component bundled with NitroSense and PredatorSense . A WebSocket service was configured to listen on all network interfaces rather than a restricted one, which may expose the service to unintended network access. The CVSS 4.0 base score is 6.9 (M...
CVE-2026-50604
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The socket handshake process does not properly require authentication before granting access to the service. Under certain circumstances, an unauthorized connection may be...
CVE-2026-50603
A vulnerability has been identified in the Acer Agent Service component included with NitroSense and PredatorSense. The vulnerability is caused by the use of a hard-coded AES encryption key within the software. Under certain circumstances, a local attacker may be able to use the embedded key to...
CVE-2026-50604
CVE-2026-50604 affects the Acer Agent Service component bundled with NitroSense and PredatorSense software. The root cause is a missing authentication check during the socket handshake process, which allows an unauthenticated local attacker to establish a connection and access functionality that ...
CVE-2026-9789
CVE 编号: CVE-2026-9789 研究人员: Vo Duc Thang ugvxb 致谢: https://community.acer.com/en/kb/articles/19670 视频 POC: https://drive.google.com/file/d/1B8b42bE68CWMnlqG6eJWi0txGFsHAJZc/view?usp=sharing 1. 执行摘要 在宏碁 NitroSense 软件(PSAdminAgent.exe)中发现了一个严重的本地权限提升漏洞。该漏洞允许任何经过身份验证的本地用户以 SYSTEM...
CVE-2026-8069
从宏碁命名管道到 NT AUTHORITY\SYSTEM:CVE-2026-8069 宏碁 NitroSense 和 PredatorSense 3.x 安装了一个名为 PSSvc 的 Windows 服务,该服务向本地用户暴露了一个自定义命名管道协议。其中一个协议命令接受调用者可控的可执行文件路径,复制 winlogon.exe 的令牌,并以 NT AUTHORITY\SYSTEM 身份启动该可执行文件。 该易受攻击服务中的路径限制是一个子字符串测试。以服务目录开头然后使用 .....
CVE-2026-9789
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
Exploit for CVE-2026-9789
CVE ID: CVE-2026-9789 Researcher: Vo Duc Thang ugvxb...
CVE-2026-9789
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
CVE-2026-9789 NitroSense V3: Security Vulnerability Information
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
CVE-2026-9789
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
EUVD-2026-32700
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
CVE-2026-9789 NitroSense V3: Security Vulnerability Information
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
CVE-2026-9789
The CVE-2026-9789 entry describes a Local Privilege Escalation affecting Acer NitroSense software prior to 3.01.3052. The root cause is a PSAdminAgent service that creates a Named Pipe with a weak ACL, allowing any authenticated local user to connect and issue commands. The service does not verif...
PT-2026-44171
A Local Privilege Escalation LPE vulnerability affects Acer NitroSense software versions prior to 3.01.3052. The vulnerability stems from the the PSAdminAgent service, which creates a Named Pipe with a weak Access Control List ACL. This allows any authenticated local user to connect and send...
Acer NitroSense 安全漏洞
Acer NitroSense is a gaming device performance management software developed by Acer of Taiwan, China. Versions of Acer NitroSense prior to 3.01.3052 contained security vulnerabilities. These vulnerabilities stemmed from the PSAdminAgent service creating named pipes with weak access control lists...
CVE-2026-9489
NitroSense 3.x before 3.01.3052 contains Local Privilege Escalation LPE vulnerability.The program exposes a Windows Named Pipe that uses a custom protocol to invoke internal functions. However, this Named Pipe is misconfigured, allowing any authenticated local user to execute arbitrary code with ...
CVE-2026-9489