Lucene search
+L

14692 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/01 12:00 a.m.•8 views

CVE-2025-4146: Buffer Copy without Checking Size of Input

A vulnerability, which was classified as critical, was found in Netgear EX6200 1.0.3.94. Affected is the function sub41940. The manipulation of the argument host leads to buffer overflow. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure but did no...

9.8CVSS8.1AI score0.01494EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/01 12:00 a.m.•6 views

CVE-2025-4147: Buffer Copy without Checking Size of Input

A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. Affected by this vulnerability is the function sub47F7C. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. The vendor was contacted early about this disclosure...

9.8CVSS7.9AI score0.0116EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/01 12:00 a.m.•5 views

CVE-2025-4145: Buffer Copy without Checking Size of Input

A vulnerability, which was classified as critical, has been found in Netgear EX6200 1.0.3.94. This issue affects the function sub3D0BC. The manipulation of the argument host leads to buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure but di...

9.8CVSS8AI score0.01201EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2025/05/01 12:00 a.m.•8 views

CVE-2025-4149: Buffer Copy without Checking Size of Input

A vulnerability was found in Netgear EX6200 1.0.3.94. It has been classified as critical. This affects the function sub54014. The manipulation of the argument host leads to buffer overflow. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but di...

9.8CVSS8.1AI score0.01694EPSS
SaveExploits1References1
NVD
NVD
•added 2025/04/30 11:16 p.m.•46 views

CVE-2025-4142

A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. This vulnerability affects the function sub3C8EC. The manipulation of the argument host leads to buffer overflow. The attack can be initiated remotely. The vendor was contacted early about this disclosure but di...

9.8CVSS0.01202EPSS
SaveExploits1References5
osv_cve
osv_cve
•added 2025/04/30 11:16 p.m.•18 views

CVE-2025-4142

A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. This vulnerability affects the function sub3C8EC. The manipulation of the argument host leads to buffer overflow. The attack can be initiated remotely. The vendor was contacted early about this disclosure but di...

9.8CVSS6.4AI score0.01202EPSS
SaveExploits1References5
Cvelist
Cvelist
•added 2025/04/30 10:31 p.m.•51 views

CVE-2025-4142 Netgear EX6200 sub_3C8EC buffer overflow

A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. This vulnerability affects the function sub3C8EC. The manipulation of the argument host leads to buffer overflow. The attack can be initiated remotely. The vendor was contacted early about this disclosure but di...

9CVSS0.01202EPSS
SaveExploits1References5
Vulnrichment
Vulnrichment
•added 2025/04/30 10:31 p.m.•33 views

CVE-2025-4142 Netgear EX6200 sub_3C8EC buffer overflow

A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. This vulnerability affects the function sub3C8EC. The manipulation of the argument host leads to buffer overflow. The attack can be initiated remotely. The vendor was contacted early about this disclosure but di...

9CVSS8.8AI score0.01202EPSS
SaveExploits1References5
CVE
CVE
•added 2025/04/30 10:31 p.m.•94 views

CVE-2025-4142

Netgear EX6200, firmware 1.0.3.94, is affected by CVE-2025-4142 due to a buffer overflow in the sub_3C8EC function caused by improper validation of the host argument. The vulnerability can be triggered remotely and may lead to arbitrary code execution or a denial of service. Multiple connected so...

9.8CVSS8.8AI score0.01202EPSS
SaveExploits1References5Affected Software1
NVD
NVD
•added 2025/04/30 10:15 p.m.•48 views

CVE-2025-4140

A vulnerability, which was classified as critical, has been found in Netgear EX6120 1.0.3.94. Affected by this issue is the function sub30394. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure...

9.8CVSS0.01202EPSS
SaveExploits1References5
NVD
NVD
•added 2025/04/30 10:15 p.m.•49 views

CVE-2025-4141

A vulnerability, which was classified as critical, was found in Netgear EX6200 1.0.3.94. This affects the function sub3C03C. The manipulation of the argument host leads to buffer overflow. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did...

9.8CVSS0.0116EPSS
SaveExploits1References5
osv_cve
osv_cve
•added 2025/04/30 10:15 p.m.•15 views

CVE-2025-4141

A vulnerability, which was classified as critical, was found in Netgear EX6200 1.0.3.94. This affects the function sub3C03C. The manipulation of the argument host leads to buffer overflow. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did...

9.8CVSS6.3AI score0.0116EPSS
SaveExploits1References5
osv_cve
osv_cve
•added 2025/04/30 10:15 p.m.•27 views

CVE-2025-4140

A vulnerability, which was classified as critical, has been found in Netgear EX6120 1.0.3.94. Affected by this issue is the function sub30394. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure...

9.8CVSS7.7AI score0.01202EPSS
SaveExploits1References5
Vulnrichment
Vulnrichment
•added 2025/04/30 10:00 p.m.•16 views

CVE-2025-4141 Netgear EX6200 sub_3C03C buffer overflow

A vulnerability, which was classified as critical, was found in Netgear EX6200 1.0.3.94. This affects the function sub3C03C. The manipulation of the argument host leads to buffer overflow. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did...

9CVSS7.3AI score0.0116EPSS
SaveExploits1References5
Cvelist
Cvelist
•added 2025/04/30 10:00 p.m.•54 views

CVE-2025-4141 Netgear EX6200 sub_3C03C buffer overflow

A vulnerability, which was classified as critical, was found in Netgear EX6200 1.0.3.94. This affects the function sub3C03C. The manipulation of the argument host leads to buffer overflow. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did...

9CVSS0.0116EPSS
SaveExploits1References5
CVE
CVE
•added 2025/04/30 10:00 p.m.•116 views

CVE-2025-4141

CVE-2025-4141 affects Netgear EX6200 (firmware around 1.0.3.94). The issue stems from the sub_3C03C function where the host argument length is not validated, causing a buffer overflow. This vulnerability can be triggered remotely and could lead to arbitrary code execution or a denial of service a...

9.8CVSS8.8AI score0.0116EPSS
SaveExploits1References5Affected Software1
Vulnrichment
Vulnrichment
•added 2025/04/30 9:31 p.m.•20 views

CVE-2025-4140 Netgear EX6120 sub_30394 buffer overflow

A vulnerability, which was classified as critical, has been found in Netgear EX6120 1.0.3.94. Affected by this issue is the function sub30394. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure...

9CVSS7AI score0.01202EPSS
SaveExploits1References5
Cvelist
Cvelist
•added 2025/04/30 9:31 p.m.•62 views

CVE-2025-4140 Netgear EX6120 sub_30394 buffer overflow

A vulnerability, which was classified as critical, has been found in Netgear EX6120 1.0.3.94. Affected by this issue is the function sub30394. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. The vendor was contacted early about this disclosure...

9CVSS0.01202EPSS
SaveExploits1References5
CVE
CVE
•added 2025/04/30 9:31 p.m.•109 views

CVE-2025-4140

CVE-2025-4140 affects Netgear EX6120 (firmware 1.0.3.94). The issue is a buffer overflow in the sub_30394 function caused by improper validation of the host argument, enabling remote exploitation to execute arbitrary code or cause a denial of service. Multiple sources corroborate the vulnerabilit...

9.8CVSS8.8AI score0.01202EPSS
SaveExploits1References5Affected Software1
NVD
NVD
•added 2025/04/30 9:15 p.m.•51 views

CVE-2025-4139

A vulnerability classified as critical was found in Netgear EX6120 1.0.0.68. Affected by this vulnerability is the function fwAcosCgiInbound. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. The vendor was contacted early about this disclosure b...

9CVSS0.01147EPSS
SaveExploits0References5
Rows per page
Query Builder