6548 matches found

Cvelist
Cvelist
•added 2021/08/02 12:47 p.m.•60 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8AI score0.03396EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 12:47 p.m.•125 views

CVE-2021-37164

The CVE-2021-37164 issue affects Swisslog Healthcare Nexus Control Panel (Nexus Panel). A stack-based buffer overflow is caused by an out-of-bounds write in tcpTxThread when processing received data, affecting released versions before Nexus Software 7.2.5.7. CNVD-2021-62178 confirms an out-of-bou...

9.8CVSS9.5AI score0.03396EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2021/08/02 12:46 p.m.•42 views

CVE-2021-37163

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...

9.6AI score0.03396EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 12:46 p.m.•113 views

CVE-2021-37163

CVE-2021-37163 affects Swisslog Healthcare Nexus HMI3 Control Panel (Nexus software before 7.2.5.7). The device has two hardcoded passwords and an insecure permissions issue, enabling potential unauthorized access over the network. Impact details are described as high/severe in the CVSS metrics. ...

9.8CVSS9.4AI score0.03396EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2021/08/02 12:45 p.m.•51 views

CVE-2021-37167

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...

9.7AI score0.01737EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 12:45 p.m.•128 views

CVE-2021-37167

CVE-2021-37167 affects the HMI3 Control Panel in Swisslog Healthcare Nexus Panel, specifically released builds prior to Nexus Software 7.2.5.7. An insecure permissions issue allows a user who logs in with default credentials to gain root access to the device, granting full control over device fun...

10CVSS9.5AI score0.01737EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2021/08/02 12:44 p.m.•51 views

CVE-2021-37166

A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...

7.8AI score0.02062EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 12:44 p.m.•124 views

CVE-2021-37166

CVE-2021-37166 affects Swisslog Healthcare Nexus Panel (HMI3 Control Panel). The issue is a buffer/connection handling vulnerability that occurs during startup when the HMI3 binds a local service to a TCP port on all interfaces and waits a long time for the GUI to connect, enabling an external at...

7.8CVSS7.6AI score0.02062EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2021/08/02 12:43 p.m.•61 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.6AI score0.08227EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 12:43 p.m.•132 views

CVE-2021-37160

CVE-2021-37160 impacts Swisslog Healthcare Nexus Panel firmware updates prior to Nexus Software 7.2.5.7, where there is no firmware validation (eg, cryptographic signature) during a firmware file upload. The vulnerability stems from missing validation during firmware update uploads, enabling pote...

9.8CVSS9.4AI score0.08227EPSS
SaveExploits0References4Affected Software1
Cvelist
Cvelist
•added 2021/08/02 12:42 p.m.•46 views

CVE-2021-37161

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

10AI score0.03264EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 12:42 p.m.•139 views

CVE-2021-37161

CVE-2021-37161 describes a buffer overflow in the Swisslog Healthcare Nexus Panel’s HMI3 Control Panel (pre Nexus Software 7.2.5.7) that can overwrite an internal queue data structure and lead to remote code execution. The impact is high (network, no auth, no user interaction). Remediation: upgra...

9.8CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
NVD
NVD
•added 2021/08/02 11:15 a.m.•51 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS0.03264EPSS
SaveExploits0References4
osv_cve
osv_cve
•added 2021/08/02 11:15 a.m.•20 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS7.8AI score0.03264EPSS
SaveExploits0References4
Prion
Prion
•added 2021/08/02 11:15 a.m.•40 views

Buffer overflow

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

7.5CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
attackerkb
attackerkb
•added 2021/08/02 11:15 a.m.•13 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS7.8AI score0.03264EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2021/08/02 10:48 a.m.•57 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

10AI score0.03264EPSS
SaveExploits0References4
CVE
CVE
•added 2021/08/02 10:48 a.m.•119 views

CVE-2021-37165

Technical details about CVE-2021-37165 are not publicly available in the provided Connected documents. The initial description notes a buffer overflow enabling remote code execution in Nexus Panel software prior to 7.2.5.7, but no confirmed exploit or remediation is documented here.

9.8CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
Positive Technologies
Positive Technologies
•added 2021/08/02 12:00 a.m.•2 views

PT-2021-21543

Name of the Vulnerable Software and Affected Versions Swisslog Healthcare Nexus versions prior to 7.2.5.7 Description An insecure permissions issue was discovered in the HMI3 Control Panel of Swisslog Healthcare Nexus. The device has two user accounts with hardcoded passwords. Recommendations For...

9.8CVSS0.01439EPSS
SaveExploits0References10
CNNVD
CNNVD
•added 2021/08/02 12:00 a.m.•28 views

Swisslog Healthcare Nexus Panel has a digital error vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A buffer overflow vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. An attacker can exploit this vulnerability by sending a specially crafted message to the HMI to enable remote code execution...

9.8CVSS6.5AI score0.03264EPSS
SaveExploits0References6