CVE-2021-37161

CVE-2021-37161 describes a buffer overflow in the Swisslog Healthcare Nexus Panel’s HMI3 Control Panel (pre Nexus Software 7.2.5.7) that can overwrite an internal queue data structure and lead to remote code execution. The impact is high (network, no auth, no user interaction). Remediation: upgra...

9.8CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
NVD
NVD
added 2021/08/02 11:15 a.m.43 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS0.03264EPSS
SaveExploits0References4
OSV
OSV
added 2021/08/02 11:15 a.m.11 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS7.8AI score0.03264EPSS
SaveExploits0References4
Prion
Prion
added 2021/08/02 11:15 a.m.31 views

Buffer overflow

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

7.5CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/08/02 11:15 a.m.7 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

9.8CVSS7.8AI score0.03264EPSS
SaveExploits0References6
Cvelist
Cvelist
added 2021/08/02 10:48 a.m.51 views

CVE-2021-37165

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...

10AI score0.03264EPSS
SaveExploits0References4
CVE
CVE
added 2021/08/02 10:48 a.m.105 views

CVE-2021-37165

Technical details about CVE-2021-37165 are not publicly available in the provided Connected documents. The initial description notes a buffer overflow enabling remote code execution in Nexus Panel software prior to 7.2.5.7, but no confirmed exploit or remediation is documented here.

9.8CVSS9.9AI score0.03264EPSS
SaveExploits0References4Affected Software1
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.11 views

Swisslog Healthcare Nexus Panel 数字错误漏洞

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, is vulnerable to an integer underflow vulnerability in versions prior to Nexus Control Panel 7.2.5.7. An attacker could use this vulnerability to override the internal queue data structure, which could enable remote code...

9.8CVSS6.2AI score0.03264EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.12 views

Swisslog Healthcare Nexus Panel 缓冲区错误漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An out-of-bounds write vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to cause a stack buffer overflow...

9.8CVSS6.1AI score0.03396EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.13 views

Swisslog Healthcare Nexus Panel 安全漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An elevation of privilege vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to gain root access to the device, which would allow access to all device...

10CVSS5.6AI score0.01737EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.21 views

Swisslog Healthcare Nexus Panel 数据伪造问题漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A code download without integrity check vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. The vulnerability stems from no file validation during the upload of an update. No details of the...

9.8CVSS5.7AI score0.08227EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.14 views

Swisslog Healthcare Nexus Panel 数字错误漏洞

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability can be exploited to override the internal queue data structure, allowing for remote code execution...

9.8CVSS6.1AI score0.03264EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2021/08/02 12:00 a.m.7 views

PT-2021-21547 · Swisslog · Swisslog Healthcare Nexus Panel

Name of the Vulnerable Software and Affected Versions: Swisslog Healthcare Nexus Panel versions prior to 7.2.5.7 Description: An insecure permissions issue was discovered in the HMI3 Control Panel of the Swisslog Healthcare Nexus Panel. This issue allows a user logged in using the default...

10CVSS9.4AI score0.03396EPSS
SaveExploits0References9
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.13 views

Swisslog Healthcare Nexus Panel 授权问题漏洞

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability stems from an improper method used to bind a local service to a port on the device interface. An attacker could use this...

7.8CVSS5.6AI score0.02062EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.11 views

HMI3 Control Panel 信任管理问题漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.A security vulnerability exists in the HMI3 Control Panel, which stems from an insecure privilege issue in the HMI3 Control Panel of the Swisslog Healthcare Nexus. No details of the vulnerability are currently available...

9.8CVSS5.5AI score0.01439EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2021/08/02 12:00 a.m.19 views

Swisslog Healthcare Nexus Panel 数字错误漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A buffer overflow vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. An attacker can exploit this vulnerability by sending a specially crafted message to the HMI to enable remote code execution...

9.8CVSS6.5AI score0.03264EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2021/07/07 12:00 a.m.28 views

Cisco Nexus 9000 Series Fabric Switches ACI Mode Link Layer Discovery Protocol Port DoS (cisco-sa-apic-lldap-dos-WerV9CFj)

According to its self-reported version, Cisco NX-OS Software is affected by a denial of service DoS vulnerability. The vulnerability exists in the Link Layer Discovery Protocol LLDP due to incorrect processing of LLDP on packets on an SFP interface. An unauthenticated, adjacent attacker can explo...

4.7CVSS5.2AI score0.00253EPSS
SaveExploits0References3
NVD
NVD
added 2021/06/18 12:15 a.m.36 views

CVE-2021-34553

Sonatype Nexus Repository Manager 3.x before 3.31.0 allows a remote authenticated attacker to get a list of blob files and read the content of a blob file via a GET request without having been granted access...

4.3CVSS0.03675EPSS
SaveExploits0References1
Prion
Prion
added 2021/06/18 12:15 a.m.23 views

Design/Logic Flaw

Sonatype Nexus Repository Manager 3.x before 3.31.0 allows a remote authenticated attacker to get a list of blob files and read the content of a blob file via a GET request without having been granted access...

4CVSS4.5AI score0.03675EPSS
SaveExploits0References1Affected Software1
ATTACKERKB
ATTACKERKB
added 2021/06/18 12:15 a.m.14 views

CVE-2021-34553

Sonatype Nexus Repository Manager 3.x before 3.31.0 allows a remote authenticated attacker to get a list of blob files and read the content of a blob file via a GET request without having been granted access...