Lucene search
+L

460 matches found

Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.14 views

Siemens Simatic Unspecified Vulnerability

Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. File data ot500265.nasl...

4.3CVSS5.2AI score0.02204EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Schneider-electric Modicon Insufficiently Protected Credentials

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...

9.8CVSS3AI score0.0225EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Schneider-electric Quantum Improper Authentication

The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a ...

10CVSS4.5AI score0.02642EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.37 views

Rockwellautomation Ab Unspecified Vulnerability

Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits. File data...

7.1CVSS5AI score0.0405EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.20 views

Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions

A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. File data ot500243.nasl...

5CVSS3.2AI score0.02304EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.15 views

Honeywell Controller Asset Information

This plugin returns asset information for a Honeywell controller. File data ot500007.nasl...

0.5AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.34 views

Schneider-electric Modicon Authentication Bypass by Capture-replay

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a...

9.8CVSS3.7AI score0.02478EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Yokogawa Exaopc Improper Access Control

BKBCopyD.exe in the Batch Management Packages in Yokogawa CENTUM CS 3000 through R3.09.50 and CENTUM VP through R4.03.00 and R5.x through R5.04.00, and Exaopc through R3.72.10, does not require authentication, which allows remote attackers to read arbitrary files via a RETR operation, write to...

7.5CVSS4.3AI score0.36035EPSS
SaveExploits6References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Yokogawa Exaopc Improper Restriction of Operations within the Bounds of a Memory Buffer

Stack-based buffer overflow in BKFSimvhfd.exe in Yokogawa CENTUM CS 1000, CENTUM CS 3000 R3.09.50 and earlier, CENTUM VP R5.03.20 and earlier, Exaopc R3.72.00 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier, when FCS/Test Function is enabled, allows remote attacke...

8.3CVSS6.7AI score0.62312EPSS
SaveExploits6References6
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Rockwellautomation Micrologix Unspecified Vulnerability

An exploitable denial of service vulnerability exists in the program download functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a device fault resulting in halted operations. An attacker can send an unauthenticated packet to trigger...

7.8CVSS2.7AI score0.04662EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.30 views

Windriver Vxworks Unspecified Vulnerability

Wind River VxWorks 6.5, 6.6, 6.7, 6.8, 6.9.3 and 6.9.4 has a Memory Leak in the IGMPv3 client component. There is an IPNET security vulnerability: IGMP Information leak via IGMPv3 specific membership report. File data ot500056.nasl...

5CVSS3.2AI score0.59798EPSS
SaveExploits0References9
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.28 views

Siemens Simatic Unspecified Vulnerability

The random-number generator on Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors, a different vulnerability than...

8.3CVSS5.1AI score0.03156EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Siemens Simatic Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. File data ot500100.nasl...

4.3CVSS3.6AI score0.02556EPSS
SaveExploits1References6
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.21 views

Schneider-electric Modicon Improper Input Validation

A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software. File data ot500234.nasl...

5CVSS3.9AI score0.01509EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.20 views

Rockwellautomation Factorytalk Improper Input Validation

The FactoryTalk FT RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service service outage via a craft...

5CVSS5.2AI score0.1021EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.92 views

Rockwellautomation Factorytalk Unspecified Vulnerability

Untrusted search path vulnerability in the Clean Utility application in Rockwell Automation FactoryTalk Services Platform before 2.71.00 and FactoryTalk View Studio 8.00.00 and earlier allows local users to gain privileges via a Trojan horse DLL in an unspecified directory. File data ot500135.nas...

6.9CVSS5.6AI score0.00688EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.26 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service device restart and STOP transition via crafted TCP packets. File data ot500045.nasl...

7.1CVSS5.8AI score0.09696EPSS
SaveExploits3References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Schneider-electric Modicon Improper Control of Generation of Code ('Code Injection')

In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. File data ot500209.nasl...

6.4CVSS4.3AI score0.0145EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.37 views

Rockwellautomation 1766-l32awa Improper Access Control

Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32BXBA devices have a hardcoded SNMP community, which makes it easier for remote attackers to load arbitrary firmware updates by leveraging knowledge of this community. File data...

7.5CVSS4.4AI score0.29613EPSS
SaveExploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Rockwellautomation Factorytalk Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

SQL injection vulnerability in Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 allows remote attackers to execute arbitrary SQL commands via unspecified vectors. File data ot500180.nasl...

7.5CVSS7AI score0.06297EPSS
SaveExploits0References3
Rows per page
Query Builder